Comparison of two deep learning image reconstruction algorithms in chest CT images: A task-based image quality assessment on phantom data

被引:42
|
作者
Greffier, Joel [1 ]
Frandon, Julien [1 ]
Si-Mohamed, Salim [2 ]
Dabli, Djamel [1 ]
Hamard, Aymeric [1 ]
Belaouni, Asmaa [1 ]
Akessoul, Philippe [1 ]
Besse, Francis [3 ]
Guiu, Boris [4 ]
Beregi, Jean-Paul [1 ]
机构
[1] Univ Montpellier, CHU Nimes, Med Imaging Grp Nimes, Dept Med Imaging,EA 2992, F-30029 Nimes, France
[2] Hosp Civils Lyon, Dept Radiol, F-69500 Lyon, France
[3] Ctr Cardiol Nord, Dept Radiol, F-93200 St Denis, France
[4] St Eloi Univ Hosp, Dept Radiol, F-34295 Montpellier, France
关键词
Multidetector computed tomography; Task -based image quality assessment; Deep learning image reconstruction; ITERATIVE RECONSTRUCTION; OPTIMIZATION; ACQUISITION;
D O I
10.1016/j.diii.2021.08.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to compare the effect of two deep learning image reconstruction (DLR) algorithms in chest computed tomography (CT) with different clinical indications. Material and methods: Acquisitions on image quality and anthropomorphic phantoms were performed at six dose levels (CTDIvol: 10/7.5/5/2.5/1/0.5mGy) on two CT scanners equipped with two different DLR algorithms (TrueFidelityTM and AiCE). Raw data were reconstructed using the filtered back-projection (FBP) and the lowest/intermediate/highest DLR levels (L-DLR/M-DLR/H-DLR) of each algorithm. Noise power spectrum, taskbased transfer function (TTF) and detectability index (d') were computed: d' modelled detection of a soft tissue mediastinal nodule, ground-glass opacity, or high-contrast pulmonary lesion. Subjective image quality of anthropomorphic phantom images was analyzed by two radiologists. Results: For the L-DLR/M-DLR levels, the noise magnitude was lower with TrueFidelityTM than with AiCE from 2.5 to 10 mGy. For H-DLR, noise magnitude was lower with AiCE . For L-DLR and M-DLR, the average NPS spatial frequency (fav) values were greater for AiCE except for 0.5 mGy. For H-DLR levels, fav was greater for TrueFidelityTM than for AiCE. TTF50% values were greater with AiCE for the air insert, and lower than TrueFidelityTM for the polyethylene insert. From 2.5 to10 mGy, d' was greater for AiCE than for TrueFidelityTM for H-DLR for all lesions, but similar for L-DLR and M-DLR. Image quality was rated clinically appropriate for all levels of both algorithms, for dose from 2.5 to 10 mGy, except for L-DLR of AiCE. Conclusion: DLR algorithms reduce the image-noise and improve lesion detectability. Their operations and properties impacted both noise-texture and spatial resolution. (c) 2021 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:21 / 30
页数:10
相关论文
共 50 条
  • [1] CT iterative reconstruction algorithms: a task-based image quality assessment
    Greffier, J.
    Frandon, J.
    Larbi, A.
    Beregi, J. P.
    Pereira, F.
    EUROPEAN RADIOLOGY, 2020, 30 (01) : 487 - 500
  • [2] CT iterative reconstruction algorithms: a task-based image quality assessment
    J. Greffier
    J. Frandon
    A. Larbi
    J. P. Beregi
    F. Pereira
    European Radiology, 2020, 30 : 487 - 500
  • [3] Comparison of two deep-learning image reconstruction algorithms on cardiac CT images: A phantom study
    Greffier, Joel
    Pastor, Maxime
    Si-Mohamed, Salim
    Goutain-Majorel, Cynthia
    Peudon-Balas, Aude
    Bensalah, Mourad Zoubir
    Frandon, Julien
    Beregi, Jean-Paul
    Dabli, Djamel
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2024, 105 (03) : 110 - 117
  • [4] iQMetrix-CT: New software for task-based image quality assessment of phantom CT images
    Greffier, Joel
    Barbotteau, Yves
    Gardavaud, Francois
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (11) : 555 - 562
  • [5] A Novel Phantom for CT Performance Assessment: Towards a Task-Based Measure of Image Quality
    Richard, S.
    Samei, E.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [6] Comparison of two versions of a deep learning image reconstruction algorithm on CT image quality and dose reduction: A phantom study
    Greffier, Joel
    Dabli, Djamel
    Frandon, Julien
    Hamard, Aymeric
    Belaouni, Asmaa
    Akessoul, Philippe
    Fuamba, Yannick
    Le Roy, Julien
    Guiu, Boris
    Beregi, Jean-Paul
    MEDICAL PHYSICS, 2021, 48 (10) : 5743 - 5755
  • [7] Image quality assessment of pediatric chest and abdomen CT by deep learning reconstruction
    Yoon, Haesung
    Kim, Jisoo
    Lim, Hyun Ji
    Lee, Mi-Jung
    BMC MEDICAL IMAGING, 2021, 21 (01)
  • [8] Image quality assessment of pediatric chest and abdomen CT by deep learning reconstruction
    Haesung Yoon
    Jisoo Kim
    Hyun Ji Lim
    Mi-Jung Lee
    BMC Medical Imaging, 21
  • [9] The image quality of deep-learning image reconstruction of chest CT images on a mediastinal window setting
    Hata, A.
    Yanagawa, M.
    Yoshida, Y.
    Miyata, T.
    Kikuchi, N.
    Honda, O.
    Tomiyama, N.
    CLINICAL RADIOLOGY, 2021, 76 (02) : 155.e15 - 155.e23
  • [10] Task-based characterization of a deep learning image reconstruction and comparison with filtered back-projection and a partial model-based iterative reconstruction in abdominal CT: A phantom study
    Racine, Damien
    Becce, Fabio
    Viry, Anais
    Monnin, Pascal
    Thomsen, Brian
    Verdun, Francis R.
    Rotzinger, David C.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 76 : 28 - 37