Comparison of two deep learning image reconstruction algorithms in chest CT images: A task-based image quality assessment on phantom data

被引:42
|
作者
Greffier, Joel [1 ]
Frandon, Julien [1 ]
Si-Mohamed, Salim [2 ]
Dabli, Djamel [1 ]
Hamard, Aymeric [1 ]
Belaouni, Asmaa [1 ]
Akessoul, Philippe [1 ]
Besse, Francis [3 ]
Guiu, Boris [4 ]
Beregi, Jean-Paul [1 ]
机构
[1] Univ Montpellier, CHU Nimes, Med Imaging Grp Nimes, Dept Med Imaging,EA 2992, F-30029 Nimes, France
[2] Hosp Civils Lyon, Dept Radiol, F-69500 Lyon, France
[3] Ctr Cardiol Nord, Dept Radiol, F-93200 St Denis, France
[4] St Eloi Univ Hosp, Dept Radiol, F-34295 Montpellier, France
关键词
Multidetector computed tomography; Task -based image quality assessment; Deep learning image reconstruction; ITERATIVE RECONSTRUCTION; OPTIMIZATION; ACQUISITION;
D O I
10.1016/j.diii.2021.08.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to compare the effect of two deep learning image reconstruction (DLR) algorithms in chest computed tomography (CT) with different clinical indications. Material and methods: Acquisitions on image quality and anthropomorphic phantoms were performed at six dose levels (CTDIvol: 10/7.5/5/2.5/1/0.5mGy) on two CT scanners equipped with two different DLR algorithms (TrueFidelityTM and AiCE). Raw data were reconstructed using the filtered back-projection (FBP) and the lowest/intermediate/highest DLR levels (L-DLR/M-DLR/H-DLR) of each algorithm. Noise power spectrum, taskbased transfer function (TTF) and detectability index (d') were computed: d' modelled detection of a soft tissue mediastinal nodule, ground-glass opacity, or high-contrast pulmonary lesion. Subjective image quality of anthropomorphic phantom images was analyzed by two radiologists. Results: For the L-DLR/M-DLR levels, the noise magnitude was lower with TrueFidelityTM than with AiCE from 2.5 to 10 mGy. For H-DLR, noise magnitude was lower with AiCE . For L-DLR and M-DLR, the average NPS spatial frequency (fav) values were greater for AiCE except for 0.5 mGy. For H-DLR levels, fav was greater for TrueFidelityTM than for AiCE. TTF50% values were greater with AiCE for the air insert, and lower than TrueFidelityTM for the polyethylene insert. From 2.5 to10 mGy, d' was greater for AiCE than for TrueFidelityTM for H-DLR for all lesions, but similar for L-DLR and M-DLR. Image quality was rated clinically appropriate for all levels of both algorithms, for dose from 2.5 to 10 mGy, except for L-DLR of AiCE. Conclusion: DLR algorithms reduce the image-noise and improve lesion detectability. Their operations and properties impacted both noise-texture and spatial resolution. (c) 2021 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:21 / 30
页数:10
相关论文
共 50 条
  • [41] Deep learning image reconstruction in pediatric abdominal and chest computed tomography: a comparison of image quality and radiation dose
    Zhang, Kun
    Shi, Xiang
    Xie, Shuang-Shuang
    Sun, Ji-Hang
    Liu, Zhuo-Heng
    Zhang, Shuai
    Song, Jia-Yang
    Shen, Wen
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (06) : 3238 - +
  • [42] Influence of deep learning reconstruction on task-based model observer performance in CT: an anthropomorphic head phantom study
    Hernandez-Giron, Irene
    Kaasalainen, Touko
    Makela, Teemu
    Peltonen, Juha
    Kortesniemi, Mika
    MEDICAL IMAGING 2022: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2022, 12035
  • [43] Image Quality Assessment of Abdominal CT by Use of New Deep Learning Image Reconstruction: Initial Experience
    Jensen, Corey T.
    Liu, Xinming
    Tamm, Eric P.
    Chandler, Adam G.
    Sun, Jia
    Morani, Ajaykumar C.
    Javadi, Sanaz
    Wagner-Bartak, Nicolaus A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (01) : 50 - 57
  • [44] Deep learning image reconstruction for quality assessment of iodine concentration in computed tomography: A phantom study
    Jeon, Pil-Hyun
    Lee, Chang-Lae
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2023, 31 (02) : 409 - 422
  • [45] A Task-based comparison of two reconstruction algorithms for digital breast tomosynthesis
    Mahadevan, Ravi
    Ikejimba, Lynda C.
    Lin, Yuan
    Samei, Ehsan
    Lo, Joseph Y.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [46] Super-resolution deep-learning reconstruction for cardiac CT: impact of radiation dose and focal spot size on task-based image quality
    Emoto, Takafumi
    Nagayama, Yasunori
    Takada, Sentaro
    Sakabe, Daisuke
    Shigematsu, Shinsuke
    Goto, Makoto
    Nakato, Kengo
    Yoshida, Ryuya
    Harai, Ryota
    Kidoh, Masafumi
    Oda, Seitaro
    Nakaura, Takeshi
    Hirai, Toshinori
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (03) : 1001 - 1014
  • [47] Efficient and Quantitative Measurement of Task-Based Image Quality Metrics in CT
    Dirks, S.
    Yu, L.
    Vrieze, T.
    Favazza, C.
    Ferrero, A.
    Leng, S.
    Weaver, J.
    McCollough, C.
    MEDICAL PHYSICS, 2017, 44 (06) : 3315 - 3315
  • [48] Assessment of temporal resolution and detectability of moving objects in CT: A task-based image quality study
    Monnin, P.
    Rotzinger, D.
    Viry, A.
    Vitzthum, V.
    Racine, D.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 120
  • [49] Task-based image quality assessment of an intraoperative CBCT for spine surgery compared with conventional CT
    Vorbau, Robert
    Hulthen, Markus
    Omar, Artur
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 124
  • [50] Impact of four kVp combinations available in a dual-source CT on the spectral performance of abdominal imaging: A task-based image quality assessment on phantom data
    Greffier, Joel
    Frandon, Julien
    Sadate, Alexandre
    Akessoul, Philippe
    Belaouni, Asmaa
    Beregi, Jean-Paul
    Dabli, Djamel
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (08): : 243 - 254