Comparison of two deep learning image reconstruction algorithms in chest CT images: A task-based image quality assessment on phantom data

被引:42
|
作者
Greffier, Joel [1 ]
Frandon, Julien [1 ]
Si-Mohamed, Salim [2 ]
Dabli, Djamel [1 ]
Hamard, Aymeric [1 ]
Belaouni, Asmaa [1 ]
Akessoul, Philippe [1 ]
Besse, Francis [3 ]
Guiu, Boris [4 ]
Beregi, Jean-Paul [1 ]
机构
[1] Univ Montpellier, CHU Nimes, Med Imaging Grp Nimes, Dept Med Imaging,EA 2992, F-30029 Nimes, France
[2] Hosp Civils Lyon, Dept Radiol, F-69500 Lyon, France
[3] Ctr Cardiol Nord, Dept Radiol, F-93200 St Denis, France
[4] St Eloi Univ Hosp, Dept Radiol, F-34295 Montpellier, France
关键词
Multidetector computed tomography; Task -based image quality assessment; Deep learning image reconstruction; ITERATIVE RECONSTRUCTION; OPTIMIZATION; ACQUISITION;
D O I
10.1016/j.diii.2021.08.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of this study was to compare the effect of two deep learning image reconstruction (DLR) algorithms in chest computed tomography (CT) with different clinical indications. Material and methods: Acquisitions on image quality and anthropomorphic phantoms were performed at six dose levels (CTDIvol: 10/7.5/5/2.5/1/0.5mGy) on two CT scanners equipped with two different DLR algorithms (TrueFidelityTM and AiCE). Raw data were reconstructed using the filtered back-projection (FBP) and the lowest/intermediate/highest DLR levels (L-DLR/M-DLR/H-DLR) of each algorithm. Noise power spectrum, taskbased transfer function (TTF) and detectability index (d') were computed: d' modelled detection of a soft tissue mediastinal nodule, ground-glass opacity, or high-contrast pulmonary lesion. Subjective image quality of anthropomorphic phantom images was analyzed by two radiologists. Results: For the L-DLR/M-DLR levels, the noise magnitude was lower with TrueFidelityTM than with AiCE from 2.5 to 10 mGy. For H-DLR, noise magnitude was lower with AiCE . For L-DLR and M-DLR, the average NPS spatial frequency (fav) values were greater for AiCE except for 0.5 mGy. For H-DLR levels, fav was greater for TrueFidelityTM than for AiCE. TTF50% values were greater with AiCE for the air insert, and lower than TrueFidelityTM for the polyethylene insert. From 2.5 to10 mGy, d' was greater for AiCE than for TrueFidelityTM for H-DLR for all lesions, but similar for L-DLR and M-DLR. Image quality was rated clinically appropriate for all levels of both algorithms, for dose from 2.5 to 10 mGy, except for L-DLR of AiCE. Conclusion: DLR algorithms reduce the image-noise and improve lesion detectability. Their operations and properties impacted both noise-texture and spatial resolution. (c) 2021 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:21 / 30
页数:10
相关论文
共 50 条
  • [31] Preserving image texture while reducing radiation dose with a deep learning image reconstruction algorithm in chest CT: A phantom study
    Franck, Caro
    Zhang, Guozhi
    Deak, Paul
    Zanca, Federica
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 81 : 86 - 93
  • [32] Development of a method to create uniform phantoms for task-based assessment of CT image quality
    Conzelmann, Juliane
    Schwarz, Felix Benjamin
    Hamm, Bernd
    Scheel, Michael
    Jahnke, Paul
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (09): : 201 - 208
  • [33] Comparison of Image Quality Assessment Algorithms on Compressed Images
    Charrier, Christophe
    Knoblauch, Kenneth
    Moorthy, Anush K.
    Bovik, Alan C.
    Maloney, Laurence T.
    IMAGE QUALITY AND SYSTEM PERFORMANCE VII, 2010, 7529
  • [34] Deep learning image reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of image quality and radiation dose in a phantom study
    Hye Joo Park
    Seo-Youn Choi
    Ji Eun Lee
    Sanghyeok Lim
    Min Hee Lee
    Boem Ha Yi
    Jang Gyu Cha
    Ji Hye Min
    Bora Lee
    Yunsub Jung
    European Radiology, 2022, 32 : 3974 - 3984
  • [35] Deep learning image reconstruction algorithm for abdominal multidetector CT at different tube voltages: assessment of image quality and radiation dose in a phantom study
    Park, Hye Joo
    Choi, Seo-Youn
    Lee, Ji Eun
    Lim, Sanghyeok
    Lee, Min Hee
    Yi, Boem Ha
    Cha, Jang Gyu
    Min, Ji Hye
    Lee, Bora
    Jung, Yunsub
    EUROPEAN RADIOLOGY, 2022, 32 (06) : 3974 - 3984
  • [36] Task-based statistical image reconstruction for high-quality cone-beam CT
    Dang, Hao
    Stayman, J. Webster
    Xu, Jennifer
    Zbijewski, Wojciech
    Sisniega, Alejandro
    Mow, Michael
    Wang, Xiaohui
    Foos, David H.
    Aygun, Nafi
    Koliatsos, Vassilis E.
    Siewerdsen, Jeffrey H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (22): : 8693 - 8719
  • [37] Virtual monoenergetic images from dual-energy CT: systematic assessment of task-based image quality performance
    Cester, Davide
    Eberhard, Matthias
    Alkadhi, Hatem
    Euler, Andre
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (01) : 726 - +
  • [38] Image Quality and Lesion Detection on Deep Learning Reconstruction and Iterative Reconstruction of Submillisievert Chest and Abdominal CT
    Singh, Ramandeep
    Digumarthy, Subba R.
    Muse, Victorine V.
    Kambadakone, Avinash R.
    Blake, Michael A.
    Tabari, Azadeh
    Hoi, Yiemeng
    Akino, Naruomi
    Angel, Erin
    Madan, Rachna
    Kalra, Mannudeep K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 214 (03) : 566 - 573
  • [39] Phantom task-based image quality assessment of three generations of rapid kV-switching dual-energy CT systems on virtual monoenergetic images
    Greffier, Joel
    Viry, Anais
    Barbotteau, Yves
    Frandon, Julien
    Loisy, Maeliss
    de Oliveira, Fabien
    Beregi, Jean Paul
    Dabli, Djamel
    MEDICAL PHYSICS, 2022, 49 (04) : 2233 - 2244
  • [40] Deep Learning-Based Versus Iterative Image Reconstruction for Unenhanced Brain CT: A Quantitative Comparison of Image Quality
    Cozzi, Andrea
    Ce, Maurizio
    De Padova, Giuseppe
    Libri, Dario
    Caldarelli, Nazarena
    Zucconi, Fabio
    Oliva, Giancarlo
    Cellina, Michaela
    TOMOGRAPHY, 2023, 9 (05) : 1629 - 1637