Impact of dose reduction and the use of an advanced model-based iterative reconstruction algorithm on spectral performance of a dual-source CT system: A task-based image quality assessment

被引:24
|
作者
Greffier, Joel [1 ]
Dabli, Djamel [1 ]
Hamard, Aymeric [1 ]
Akessoul, Philippe [1 ]
Belaouni, Asmaa [1 ]
Beregi, Jean-Paul [1 ]
Frandon, Julien [1 ]
机构
[1] Univ Montpellier, Dept Med Imaging, Med Imaging Grp Nimes, EA 2992,CHU Nimes, Bd Pr Robert Debre, F-30029 Nimes 9, France
关键词
Multidetector computed tomography; Dual energy; Iterative reconstruction; Task-based image quality assessment; Phantom study; ENERGY CT; LIVER-LESIONS; OPTIMIZATION; TOMOGRAPHY; PULMONARY;
D O I
10.1016/j.diii.2021.03.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the impact of dose reduction and the use of an advanced modeled iterative reconstruction algorithm (ADMIRE) on image quality in low-energy monochromatic images from a dual-source dual energy computed tomography CT (DSCT) platform. Materials and methods: Acquisitions on an image-quality phantom were performed using DSCT equipment with 100/Sn150 kVp for four dose levels (CTDvol: 20/11/8/5mGy). Raw data were reconstructed for six energy levels (40/50/60/70/80/100 keV) using filtered back projection and two levels of ADMIRE (A3/A5). Noise power spectrum (NPS) and task-based transfer function (TTF) were calculated on virtual monoenergetic images (VMIs). Detectability index (d') was computed to model the detection task of two enhanced iodine lesions as function of keV. Results: Noise-magnitude was significantly reduced between 40 to 70 keV by -56 +/- 0% (SD) (range: -56%--55%) with FBP; 56 +/- 0% (SD) (-56%--56%) with A3; and -57 +/- 1% (SD) (range: -57%--56%) with A5. The average spatial frequency of the NPS peaked at 70 keV and decreased as ADMIRE level increased. TTF values at 50% were greatest at 40 keV and shifted towards lower frequencies as the keV increased. The detectability of both lesions increased with increasing dose level and ADMIRE level. For the simulated lesion with iodine at 2 mg/mL, d' values peaked at 70 keV for all reconstruction types, except for A3 at 20 mGy and A5 at 11 and 20 mGy, where d' peaked at 60 keV. For the other simulated lesion, d' values were highest at 40 keV and decreased beyond. Conclusion: At low keV on VMIs, this study confirms that iterative reconstruction reduces the noise magnitude, improves the spatial resolution and increases the detectability of enhanced iodine lesions. (C) 2021 Societe francaise de radiologie. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:405 / 412
页数:8
相关论文
共 50 条
  • [1] Assessment of the dose reduction potential of a model-based iterative reconstruction algorithm using a task-based performance metrology
    Samei, Ehsan
    Richard, Samuel
    MEDICAL PHYSICS, 2015, 42 (01) : 314 - 323
  • [2] CT iterative reconstruction algorithms: a task-based image quality assessment
    Greffier, J.
    Frandon, J.
    Larbi, A.
    Beregi, J. P.
    Pereira, F.
    EUROPEAN RADIOLOGY, 2020, 30 (01) : 487 - 500
  • [3] CT iterative reconstruction algorithms: a task-based image quality assessment
    J. Greffier
    J. Frandon
    A. Larbi
    J. P. Beregi
    F. Pereira
    European Radiology, 2020, 30 : 487 - 500
  • [4] Assessment of image quality in abdominal CT: potential dose reduction with model-based iterative reconstruction
    Kataria, Bharti
    Althen, Jonas Nilsson
    Smedby, Orjan
    Persson, Anders
    Sokjer, Hannibal
    Sandborg, Michael
    EUROPEAN RADIOLOGY, 2018, 28 (06) : 2464 - 2473
  • [5] Assessment of image quality in abdominal CT: potential dose reduction with model-based iterative reconstruction
    Bharti Kataria
    Jonas Nilsson Althén
    Örjan Smedby
    Anders Persson
    Hannibal Sökjer
    Michael Sandborg
    European Radiology, 2018, 28 : 2464 - 2473
  • [6] Impact of four kVp combinations available in a dual-source CT on the spectral performance of abdominal imaging: A task-based image quality assessment on phantom data
    Greffier, Joel
    Frandon, Julien
    Sadate, Alexandre
    Akessoul, Philippe
    Belaouni, Asmaa
    Beregi, Jean-Paul
    Dabli, Djamel
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (08): : 243 - 254
  • [7] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Park, Eun-Ah
    Lee, Whal
    Kim, Kwang Woo
    Kim, Kwang Gi
    Thomas, Allmendinger
    Chung, Jin Wook
    Park, Jae Hyung
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (07): : 1775 - 1786
  • [8] Iterative reconstruction of dual-source coronary CT angiography: assessment of image quality and radiation dose
    Eun-Ah Park
    Whal Lee
    Kwang Woo Kim
    Kwang Gi Kim
    Allmendinger Thomas
    Jin Wook Chung
    Jae Hyung Park
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1775 - 1786
  • [9] CT colonography with spectral filtration and advanced modeled iterative reconstruction in the thirdgeneration dual-source CT: image quality, radiation dose and performance in clinical utility
    Liu, Jing-juan
    Xue, Hua-dan
    Liu, Wei
    Yan, Jing
    Pan, Wei-dong
    Li, Bin
    Xu, Kai
    Wang, Yun
    Li, Ping
    Xiao, Yi
    Jin, Zheng-yu
    ACADEMIC RADIOLOGY, 2021, 28 (05) : E127 - E136
  • [10] Task-Based Model Observer Assessment of A Partial Model-Based Iterative Reconstruction Algorithm in Thoracic Oncologic Multidetector CT
    Rotzinger, David C.
    Racine, Damien
    Beigelman-Aubry, Catherine
    Alfudhili, Khalid M.
    Keller, Nathalie
    Monnin, Pascal
    Verdun, Francis R.
    Becce, Fabio
    SCIENTIFIC REPORTS, 2018, 8