A CORRELATION BETWEEN BONE (B), INSERTION TORQUE (IT), AND IMPLANT STABILITY (S): BITS SCORE

被引:37
|
作者
Herekar, Manisha [1 ]
Sethi, Megha [1 ]
Ahmad, Tousif [1 ]
Fernandes, Aquaviva Sebasteao
Patil, Viraj [1 ]
Kulkarni, Harish [2 ]
机构
[1] Maratha Mandals Nathajirao G Halgekar Inst Dent S, Dept Prosthodont, Belgaum, Karnataka, India
[2] Tatyasaheb Kore Dent Coll & Res Ctr, Dept Oral & Maxillofacial Surg, Warnanagar, Maharashtra, India
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2014年 / 112卷 / 04期
关键词
RESONANCE FREQUENCY-ANALYSIS; COMPUTERIZED-TOMOGRAPHY VALUES; BIOMECHANICAL ASPECTS; ENDOSSEOUS IMPLANTS; TITANIUM IMPLANTS; DENSITY; PLACEMENT;
D O I
10.1016/j.prosdent.2014.02.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Although criteria for assessing bone quality have been reported, an overall score that correlates bone quality with the primary stability and secondary stability of implants is not yet available. Purpose. The purpose of this article was to propose a scoring index that will establish a correlation among the bone density values from computed tomography, maximum insertion torque values, and resonance frequency analysis in different phases of implant treatment. Material and methods. In this study, 60 implant sites were evaluated to assess bone density (Hounsfield units), insertion torque values (Ncm), and primary stability and secondary stability (implant stability quotient values obtained by using resonance frequency analysis). On the basis of computed tomography data, the bone was classified as D1 to D4. The insertion torque was noted and classified into 2 groups, A and B. The implant stability quotient values obtained from resonance frequency analysis depicting primary stability and secondary stability were classified into 5 groups. The primary score noted was a result of the values obtained for the 3 parameters at the time of implant placement. The secondary score was obtained by considering the values of the bone density and resonance frequency analysis recorded at different time intervals. Results. Bone densities of D2, D3, and D4 were noted, dividing the bone type into 3 groups. The maximum torque noted in the study was 40 Ncm. The difference between various insertion torque values and bone types was found to be statistically nonsignificant. Higher mean implant stability quotient values were obtained for primary and secondary stability for the D2 bone than for D3 and D4 bone. When analyzed according to the time of insertion, the mean values increased at second stage surgery in all bone types. The difference in mean values among all bone types was found to be statistically significant (P<.001). A comparison of primary and secondary implant stability quotient values in all bone types did not find any statistical significance (P=.780). A score was recorded at the time of implant placement and at the time of second stage surgery, and the prosthetic treatment was planned accordingly. Conclusions. The score highlight the importance of considering the association of bone quality, insertion torque values, and stability as denoted by implant stability quotient throughout treatment. Based on the variation. in the score noted at recall visits, alterations in the treatment plan can be made with respect to the healing period and prosthetic design.
引用
收藏
页码:805 / 810
页数:6
相关论文
共 50 条
  • [41] The Influence of Low Insertion Torque on Primary Stability, Implant Survival, and Maintenance of Marginal Bone Levels: A Closed-Cohort Prospective Study
    Norton, Michael R.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) : 849 - 857
  • [42] Correlation between peri-implant bone mineral density and primary implant stability based on artificial intelligence classification
    Xiao, Yanjun
    Lv, Lingfeng
    Xu, Zonghe
    Zhou, Lin
    Lin, Yanjun
    Lin, Yue
    Guo, Jianbin
    Chen, Jiang
    Ou, Yanjing
    Lin, Lin
    Wu, Dong
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [43] The Effects of High Insertion Torque Versus Low Insertion Torque on Marginal Bone Resorption and Implant Failure Rates: A Systematic Review With Meta-Analyses
    Berardini, Marco
    Trisi, Paolo
    Sinjari, Bruna
    Rutjes, Anne W. S.
    Caputi, Sergio
    IMPLANT DENTISTRY, 2016, 25 (04) : 532 - 540
  • [44] The Effect of Implant Design and Bone Quality on Insertion Torque, Resonance Frequency Analysis, and Insertion Energy During Implant Placement in Low or Low- to Medium-Density Bone
    Wang, Tong-Mei
    Lee, Ming-Shu
    Wang, Juo-Song
    Lin, Li-Deh
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (01) : 40 - 47
  • [45] Correlation between Implant Surface Roughness and Implant Stability: A Systematic Review
    Romero-Serrano, Marta
    Romero-Ruiz, Manuel-Maria
    Herrero-Climent, Mariano
    Rios-Carrasco, Blanca
    Gil-Mur, Javier
    DENTISTRY JOURNAL, 2024, 12 (09)
  • [46] Correlation between the thickness of the crestal and buccolingual cortical bone at varying depths and implant stability quotients
    Chatvaratthana, Kanthanat
    Thaworanunta, Sita
    Seriwatanachai, Dutmanee
    Wongsirichat, Natthamet
    PLOS ONE, 2017, 12 (12):
  • [47] Relationship between implant primary stability (torque and ISQ) and bone density assessed by CBCT-clinical trial
    Gomes, R. Z.
    Lopes da Silva, L.
    Coimbra, J.
    Guerra, I.
    Vasconcelos, M.
    Correia, A.
    Braga, A. C.
    BIODENTAL ENGINEERING III, 2014, : 125 - 130
  • [48] A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables
    Lee, Su-Young
    Piao, Chunmei
    Heo, Seong-Joo
    Koak, Jai-Young
    Lee, Joo-Hee
    Kim, Tae-Hyung
    Kim, Myung-Joo
    Kwon, Ho-Beom
    Kim, Seong-Kyun
    JOURNAL OF ADVANCED PROSTHODONTICS, 2010, 2 (04): : 148 - 153
  • [49] The relationship between implant stability quotient values and implant insertion variables: a clinical study
    Park, K-J
    Kwon, J-Y
    Kim, S-K
    Heo, S-J
    Koak, J-Y
    Lee, J-H
    Lee, S-J
    Kim, T-H
    Kim, M-J
    JOURNAL OF ORAL REHABILITATION, 2012, 39 (02) : 151 - 159
  • [50] Randomized Clinical Trial Comparing Insertion Torque and Implant Stability of Two Different Implant Macrogeometries in the Initial Periods of Osseointegration
    Gehrke, Sergio Alexandre
    Cortellari, Guillermo Castro
    Fernandes, Gustavo Vicentis de Oliveira
    Scarano, Antonio
    Martins, Rafael Garcia
    Cancado, Renata Moreira
    Mesquita, Alfredo Mikail Melo
    MEDICINA-LITHUANIA, 2023, 59 (01):