A CORRELATION BETWEEN BONE (B), INSERTION TORQUE (IT), AND IMPLANT STABILITY (S): BITS SCORE

被引:37
|
作者
Herekar, Manisha [1 ]
Sethi, Megha [1 ]
Ahmad, Tousif [1 ]
Fernandes, Aquaviva Sebasteao
Patil, Viraj [1 ]
Kulkarni, Harish [2 ]
机构
[1] Maratha Mandals Nathajirao G Halgekar Inst Dent S, Dept Prosthodont, Belgaum, Karnataka, India
[2] Tatyasaheb Kore Dent Coll & Res Ctr, Dept Oral & Maxillofacial Surg, Warnanagar, Maharashtra, India
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2014年 / 112卷 / 04期
关键词
RESONANCE FREQUENCY-ANALYSIS; COMPUTERIZED-TOMOGRAPHY VALUES; BIOMECHANICAL ASPECTS; ENDOSSEOUS IMPLANTS; TITANIUM IMPLANTS; DENSITY; PLACEMENT;
D O I
10.1016/j.prosdent.2014.02.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Although criteria for assessing bone quality have been reported, an overall score that correlates bone quality with the primary stability and secondary stability of implants is not yet available. Purpose. The purpose of this article was to propose a scoring index that will establish a correlation among the bone density values from computed tomography, maximum insertion torque values, and resonance frequency analysis in different phases of implant treatment. Material and methods. In this study, 60 implant sites were evaluated to assess bone density (Hounsfield units), insertion torque values (Ncm), and primary stability and secondary stability (implant stability quotient values obtained by using resonance frequency analysis). On the basis of computed tomography data, the bone was classified as D1 to D4. The insertion torque was noted and classified into 2 groups, A and B. The implant stability quotient values obtained from resonance frequency analysis depicting primary stability and secondary stability were classified into 5 groups. The primary score noted was a result of the values obtained for the 3 parameters at the time of implant placement. The secondary score was obtained by considering the values of the bone density and resonance frequency analysis recorded at different time intervals. Results. Bone densities of D2, D3, and D4 were noted, dividing the bone type into 3 groups. The maximum torque noted in the study was 40 Ncm. The difference between various insertion torque values and bone types was found to be statistically nonsignificant. Higher mean implant stability quotient values were obtained for primary and secondary stability for the D2 bone than for D3 and D4 bone. When analyzed according to the time of insertion, the mean values increased at second stage surgery in all bone types. The difference in mean values among all bone types was found to be statistically significant (P<.001). A comparison of primary and secondary implant stability quotient values in all bone types did not find any statistical significance (P=.780). A score was recorded at the time of implant placement and at the time of second stage surgery, and the prosthetic treatment was planned accordingly. Conclusions. The score highlight the importance of considering the association of bone quality, insertion torque values, and stability as denoted by implant stability quotient throughout treatment. Based on the variation. in the score noted at recall visits, alterations in the treatment plan can be made with respect to the healing period and prosthetic design.
引用
收藏
页码:805 / 810
页数:6
相关论文
共 50 条
  • [31] The speed of sound correlates with implant insertion torque in rabbit bone: an in vitro experiment
    Veltri, M.
    Valenti, R.
    Ceccarelli, E.
    Balleri, P.
    Nuti, R.
    Ferrari, M.
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (07) : 751 - 755
  • [32] Can we predict the insertion torque using the bone density around the implant?
    Wada, M.
    Suganami, T.
    Sogo, M.
    Maeda, Y.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (02) : 221 - 225
  • [33] Correlation of Fractal Dimension Values with Implant Insertion Torque and Resonance Frequency Values at Implant Recipient Sites
    Suer, Berkay Tolga
    Yaman, Zekai
    Buyuksarac, Bora
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (01) : 55 - 62
  • [34] A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment
    Alsaadi, Ghada
    Quirynen, Marc
    Michiels, Katleen
    Jacobs, Reinhilde
    van Steenberghe, Daniel
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2007, 34 (04) : 359 - 366
  • [35] Correlation between Primary, Secondary Stability, Bone Density, Percentage of Vital Bone Formation and Implant Size
    Ivanova, Vasilena
    Chenchev, Ivan
    Zlatev, Stefan
    Mijiritsky, Eitan
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (13)
  • [36] The correlation among gripping volume, insertion torque, and pullout strength of micro-implant
    Ting, Chun-Chan
    Hsu, Kun-Jung
    Hsiao, Szu-Yu
    Chen, Chun-Ming
    JOURNAL OF DENTAL SCIENCES, 2020, 15 (04) : 500 - 504
  • [37] Implant insertion torque and marginal bone loss: A systematic review and meta-analysis
    Roca-Millan, Elisabet
    Gonzalez-Navarro, Beatriz
    Dominguez-Minger, Judith
    Mari-Roig, Antonio
    Jane-Salas, Enric
    Lopez-Lopez, Jose
    INTERNATIONAL JOURNAL OF ORAL IMPLANTOLOGY, 2020, 13 (04) : 345 - 353
  • [38] Assessment of the Correlation Between Insertion Torque and Resonance Frequency Analysis of Implants Placed in Bone Tissue of Different Densities
    Magno Filho, Luiz Carlos
    Cirano, Fabiano Ribeiro
    Hayashi, Fernando
    Feng, Hsu Shao
    Conte, Alexandre
    Dib, Luciano Lauria
    Casati, Marcio Zaffalon
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (03) : 259 - 262
  • [39] Investigation of the Influence of Roughness and Dental Implant Design on Primary Stability via Analysis of Insertion Torque and Implant Stability Quotient: An In Vitro Study
    Romero, Marta
    Herrero-Climent, Mariano
    Rios-Carrasco, Blanca
    Brizuela, Aritza
    Romero, Manuel Maria
    Gil, Javier
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (13)
  • [40] Assessment of correlation between computerized tomography values of the bone and cutting torque values at implant placement: A clinical study
    Ikumi, N
    Tsutsumi, S
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2005, 20 (02) : 253 - 260