A CORRELATION BETWEEN BONE (B), INSERTION TORQUE (IT), AND IMPLANT STABILITY (S): BITS SCORE

被引:37
|
作者
Herekar, Manisha [1 ]
Sethi, Megha [1 ]
Ahmad, Tousif [1 ]
Fernandes, Aquaviva Sebasteao
Patil, Viraj [1 ]
Kulkarni, Harish [2 ]
机构
[1] Maratha Mandals Nathajirao G Halgekar Inst Dent S, Dept Prosthodont, Belgaum, Karnataka, India
[2] Tatyasaheb Kore Dent Coll & Res Ctr, Dept Oral & Maxillofacial Surg, Warnanagar, Maharashtra, India
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2014年 / 112卷 / 04期
关键词
RESONANCE FREQUENCY-ANALYSIS; COMPUTERIZED-TOMOGRAPHY VALUES; BIOMECHANICAL ASPECTS; ENDOSSEOUS IMPLANTS; TITANIUM IMPLANTS; DENSITY; PLACEMENT;
D O I
10.1016/j.prosdent.2014.02.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Although criteria for assessing bone quality have been reported, an overall score that correlates bone quality with the primary stability and secondary stability of implants is not yet available. Purpose. The purpose of this article was to propose a scoring index that will establish a correlation among the bone density values from computed tomography, maximum insertion torque values, and resonance frequency analysis in different phases of implant treatment. Material and methods. In this study, 60 implant sites were evaluated to assess bone density (Hounsfield units), insertion torque values (Ncm), and primary stability and secondary stability (implant stability quotient values obtained by using resonance frequency analysis). On the basis of computed tomography data, the bone was classified as D1 to D4. The insertion torque was noted and classified into 2 groups, A and B. The implant stability quotient values obtained from resonance frequency analysis depicting primary stability and secondary stability were classified into 5 groups. The primary score noted was a result of the values obtained for the 3 parameters at the time of implant placement. The secondary score was obtained by considering the values of the bone density and resonance frequency analysis recorded at different time intervals. Results. Bone densities of D2, D3, and D4 were noted, dividing the bone type into 3 groups. The maximum torque noted in the study was 40 Ncm. The difference between various insertion torque values and bone types was found to be statistically nonsignificant. Higher mean implant stability quotient values were obtained for primary and secondary stability for the D2 bone than for D3 and D4 bone. When analyzed according to the time of insertion, the mean values increased at second stage surgery in all bone types. The difference in mean values among all bone types was found to be statistically significant (P<.001). A comparison of primary and secondary implant stability quotient values in all bone types did not find any statistical significance (P=.780). A score was recorded at the time of implant placement and at the time of second stage surgery, and the prosthetic treatment was planned accordingly. Conclusions. The score highlight the importance of considering the association of bone quality, insertion torque values, and stability as denoted by implant stability quotient throughout treatment. Based on the variation. in the score noted at recall visits, alterations in the treatment plan can be made with respect to the healing period and prosthetic design.
引用
收藏
页码:805 / 810
页数:6
相关论文
共 50 条
  • [21] Correlation of cone beam CT-derived bone density parameters with primary implant stability assessed by peak insertion torque and periotest in the maxilla
    Hakim, Samer G.
    Glanz, Julia
    Ofer, Markus
    Steller, Daniel
    Sieg, Peter
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2019, 47 (03) : 461 - 467
  • [22] Correlation between bone volume fraction in posterior implant area and initial implant stability
    Tian, Tian
    Liu, Hong-hong
    Zhang, Zhi-hong
    Han, Qian
    Chen, Jia
    Lv, Jing
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2022, 133 (04): : 396 - 401
  • [23] Measurement of bone deformation and insertion torque during dental implant installation
    Nascimento, Larissa Ramos Xavier Coutinho
    Torelly, Guilherme Monteiro
    Elias, Carlos Nelson
    ORAL AND MAXILLOFACIAL SURGERY-HEIDELBERG, 2024, 29 (01):
  • [24] Development of a New Implant Primary Stability Parameter: Insertion Torque Revisited
    Degidi, Marco
    Daprile, Giuseppe
    Piattelli, Adriano
    Iezzi, Giovanna
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (05) : 637 - 644
  • [25] Correlation between insertion torque and peri-implant bone strain during placement of orthodontic mini-implants: A finite element study
    Hung, Bui Quang
    Yu, Wonjae
    Park, Hyo-Sang
    Kyung, Hee-Moon
    Hong, Mihee
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2022, 161 (02) : 248 - 254
  • [26] Primary stability, insertion torque and bone density of cylindric implant ad modum Branemark: Is there a relationship? An in vitro study
    Trisi, Paolo
    De Benedittis, Simona
    Perfetti, Giorgio
    Berardi, Davide
    CLINICAL ORAL IMPLANTS RESEARCH, 2011, 22 (05) : 567 - 570
  • [27] Relationship between implant stability measurements obtained by insertion torque and resonance frequency analysis: A systematic review
    Lages, Frederico Santos
    Douglas-de Oliveira, Dhelfeson Willya
    Costa, Fernando Oliveira
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (01) : 26 - 33
  • [28] Study to assess the relationship between insertion torque value and implant stability quotient and its influence on timing of functional implant loading
    Sarfaraz, Hasan
    Johri, Shefali
    Sucheta, P.
    Rao, Sripathi
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2018, 18 (02): : 139 - 146
  • [29] Histologic and Biomechanical Evaluation of the Effects of Implant Insertion Torque on Peri-Implant Bone Healing
    Consolo, Ugo
    Travaglini, Domenico
    Todisco, Marzio
    Trisi, Paolo
    Galli, Silvia
    JOURNAL OF CRANIOFACIAL SURGERY, 2013, 24 (03) : 860 - 865
  • [30] Correlation between Initial BIC and the Insertion Torque/Depth Integral Recorded with an Instantaneous Torque-Measuring Implant Motor: An in vivo Study
    Cappare, Paolo
    Vinci, Raffaele
    Di Stefano, Danilo Alessio
    Traini, Tonino
    Pantaleo, Giuseppe
    Gherlone, Enrico Felice
    Gastaldi, Giorgio
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E613 - E620