Study to assess the relationship between insertion torque value and implant stability quotient and its influence on timing of functional implant loading

被引:13
|
作者
Sarfaraz, Hasan [1 ]
Johri, Shefali [2 ]
Sucheta, P. [1 ]
Rao, Sripathi [2 ]
机构
[1] Yenepoya Dent Coll, Dept Prosthodont & Crown & Bridge, Univ Rd, Mangalore 575018, Karnataka, India
[2] Yenepoya Dent Coll, Dept Oral & Maxillofacial Surg, Mangalore, Karnataka, India
来源
关键词
Implant stability quotient; insertion torque value; Osstell-implant stability quotient device; primary stability; resonance frequency analysis; secondary stability; time of loading implants;
D O I
10.4103/jips.jips_203_17
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: One of the crucial requirements for the success of implants is to achieve good stability. Two well-accepted quantitative methods to assess implant stability, the insertion torque value (ITV), and resonance frequency analysis (RFA) can be a valuable adjunct to radiological and clinical examination. This study was conducted to assess the relationship between ITVs and implant stability quotient (ISQ) and its influence on timing of functional implant loading, as well as to determine the effect of some of the factors on the stability of implants. Materials and Methods: Forty implants were inserted in 37 patients in the posterior mandibular region according to conventional protocol and allowed to heal by placing a healing abutment at the time of placement. For each implant, ITV was measured at the time of the implant placement by manual torque wrench (Nobel Biocare), and the ISQ value was measured by using resonance frequency analyzer (Osstell-ISQ; Integration Diagnostics) at the baseline levels, 3rd week, 7th week, 11th week, and 15th week interval. Results: The correlation between ITV and ISQ was found to be moderately positive and significant (r = 0.399) (P = 0.000). The correlation of ITV value at baseline and ISQ values recorded at the subsequent weeks was also found to be statistically significant at week 3 (r = 0.376) (P = 0.000) and week 7 (r = 0.327) (P = 0.000). Conclusion: It can be concluded from this study that there is a positive and statistically significant correlation between the ITV and ISQ values.
引用
收藏
页码:139 / 146
页数:8
相关论文
共 50 条
  • [1] The Correlation Between Immediate Implant Insertion Torque and Implant Stability Quotient
    Levin, Barry P.
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2016, 36 (06) : 833 - 840
  • [2] The relationship between implant stability quotient values and implant insertion variables: a clinical study
    Park, K-J
    Kwon, J-Y
    Kim, S-K
    Heo, S-J
    Koak, J-Y
    Lee, J-H
    Lee, S-J
    Kim, T-H
    Kim, M-J
    JOURNAL OF ORAL REHABILITATION, 2012, 39 (02) : 151 - 159
  • [3] Are the Insertion Torque Value and Implant Stability Quotient Correlated, and If So, Can Insertion Torque Values Predict Secondary Implant Stability? A Prospective Parallel Cohort Study
    Cassetta, Michele
    Brandetti, Giulia
    Altieri, Federica
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (01) : 135 - 142
  • [4] Implant insertion torque value in immediate loading: A retrospective study
    Del Giudice, Roberto
    Piattelli, Adriano
    Grande, Nicola-Maria
    Cataneo, Enrico
    Crispino, Antonio
    Petrini, Morena
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2019, 24 (03): : E398 - E403
  • [5] Investigation of the Influence of Roughness and Dental Implant Design on Primary Stability via Analysis of Insertion Torque and Implant Stability Quotient: An In Vitro Study
    Romero, Marta
    Herrero-Climent, Mariano
    Rios-Carrasco, Blanca
    Brizuela, Aritza
    Romero, Manuel Maria
    Gil, Javier
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (13)
  • [6] Insertion Torque Value and Implant Stability Quotient: Separate Evaluation and Correlation for Different Clinical Parameters
    Ferreira, Jose Joaquim Da Rocha
    Machado, Luis Filipe Meira
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 812 - 822
  • [7] Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design
    Baldi, Domenico
    Lombardi, Teresa
    Colombo, Jacopo
    Cervino, Gabriele
    Perinetti, Giuseppe
    Di Lenarda, Roberto
    Stacchi, Claudio
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [8] A comparison of bone bed preparation with laser and conventional drill on the relationship between implant stability quotient (ISQ) values and implant insertion variables
    Lee, Su-Young
    Piao, Chunmei
    Heo, Seong-Joo
    Koak, Jai-Young
    Lee, Joo-Hee
    Kim, Tae-Hyung
    Kim, Myung-Joo
    Kwon, Ho-Beom
    Kim, Seong-Kyun
    JOURNAL OF ADVANCED PROSTHODONTICS, 2010, 2 (04): : 148 - 153
  • [9] Correlation between Periotest value and implant stability quotient: a systematic review
    Rodrigues, Alana Semenzin
    Neto, Clovis Lamartine de Moraes Melo
    Januzzi, Marcella Santos
    dos Santos, Daniela Micheline
    Goiato, Marcelo Coelho
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2024, 69 (01): : 1 - 10
  • [10] Correlation Between Implant Geometry, Implant Surface, Insertion Torque, and Primary Stability: In Vitro Biomechanical Analysis
    Falco, Antonello
    Berardini, Marco
    Trisi, Paolo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (04) : 824 - 830