Study to assess the relationship between insertion torque value and implant stability quotient and its influence on timing of functional implant loading

被引:13
|
作者
Sarfaraz, Hasan [1 ]
Johri, Shefali [2 ]
Sucheta, P. [1 ]
Rao, Sripathi [2 ]
机构
[1] Yenepoya Dent Coll, Dept Prosthodont & Crown & Bridge, Univ Rd, Mangalore 575018, Karnataka, India
[2] Yenepoya Dent Coll, Dept Oral & Maxillofacial Surg, Mangalore, Karnataka, India
来源
关键词
Implant stability quotient; insertion torque value; Osstell-implant stability quotient device; primary stability; resonance frequency analysis; secondary stability; time of loading implants;
D O I
10.4103/jips.jips_203_17
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: One of the crucial requirements for the success of implants is to achieve good stability. Two well-accepted quantitative methods to assess implant stability, the insertion torque value (ITV), and resonance frequency analysis (RFA) can be a valuable adjunct to radiological and clinical examination. This study was conducted to assess the relationship between ITVs and implant stability quotient (ISQ) and its influence on timing of functional implant loading, as well as to determine the effect of some of the factors on the stability of implants. Materials and Methods: Forty implants were inserted in 37 patients in the posterior mandibular region according to conventional protocol and allowed to heal by placing a healing abutment at the time of placement. For each implant, ITV was measured at the time of the implant placement by manual torque wrench (Nobel Biocare), and the ISQ value was measured by using resonance frequency analyzer (Osstell-ISQ; Integration Diagnostics) at the baseline levels, 3rd week, 7th week, 11th week, and 15th week interval. Results: The correlation between ITV and ISQ was found to be moderately positive and significant (r = 0.399) (P = 0.000). The correlation of ITV value at baseline and ISQ values recorded at the subsequent weeks was also found to be statistically significant at week 3 (r = 0.376) (P = 0.000) and week 7 (r = 0.327) (P = 0.000). Conclusion: It can be concluded from this study that there is a positive and statistically significant correlation between the ITV and ISQ values.
引用
收藏
页码:139 / 146
页数:8
相关论文
共 50 条
  • [31] A Comparative Study of Crestal Bone Loss and Implant Stability between Osteotome and Conventional Implant Insertion Techniques: A Randomized Controlled Clinical Trial Study
    Shayesteh, Yadollah Soleimani
    Khojasteh, Arash
    Siadat, Hakimeh
    Monzavi, Abbas
    Bassir, Seyed Hossein
    Hossaini, Mehran
    Alikhasi, Marzieh
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (03) : 350 - 357
  • [32] Influence of Bone Quality, Drilling Protocol, Implant Diameter/Length on Primary Stability: An In Vitro Comparative Study on Insertion Torque and Resonance Frequency Analysis
    Farronato, Davide
    Manfredini, Mattia
    Stocchero, Michele
    Caccia, Mattia
    Azzi, Lorenzo
    Farronato, Marco
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (03) : 182 - 189
  • [33] Correlation between implant stability quotient and bone-implant contact: A retrospective histological and histomorphometrical study of seven titanium implants retrieved from humans
    Scarano, Antonio
    Degidi, Marco
    Iezzi, Giovanna
    Petrone, Giovanna
    Piattelli, Adriano
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2006, 8 (04) : 218 - 222
  • [34] Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles
    Faot, Fernanda
    Bielemann, Amalia Machado
    Schuster, Alessandra Julie
    Marcello-Machado, Raissa Micaella
    Del Bel Cury, Altair Antoninha
    Nascimento, Gustavo G.
    Chagas-Junior, Otacilio Luiz
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [35] Effect of implant insertion and loading protocol on long-term stability and crestal bone loss: A comparative study
    Kohen, Jerry
    Matalon, Shlomo
    Block, Jonathan
    Ormianer, Zeev
    JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (06): : 697 - 702
  • [36] Assessment of Relationships Between Implant Insertion Torque and Cortical Shape of the Mandible Using Panoramic Radiography: Preliminary Study
    Tsukioka, Tsuneyuki
    Sasaki, Yusuke
    Kaneda, Takashi
    Buch, Karen
    Sakai, Osamu
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (03) : 622 - 626
  • [37] Relationship between implant primary stability (torque and ISQ) and bone density assessed by CBCT-clinical trial
    Gomes, R. Z.
    Lopes da Silva, L.
    Coimbra, J.
    Guerra, I.
    Vasconcelos, M.
    Correia, A.
    Braga, A. C.
    BIODENTAL ENGINEERING III, 2014, : 125 - 130
  • [38] Correlation between Initial BIC and the Insertion Torque/Depth Integral Recorded with an Instantaneous Torque-Measuring Implant Motor: An in vivo Study
    Cappare, Paolo
    Vinci, Raffaele
    Di Stefano, Danilo Alessio
    Traini, Tonino
    Pantaleo, Giuseppe
    Gherlone, Enrico Felice
    Gastaldi, Giorgio
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2015, 17 : E613 - E620
  • [39] The insertion torque-depth curve integral as a measure of implant primary stability: An in vitro study on polyurethane foam blocks
    Di Stefano, Danilo Alessio
    Arosio, Paolo
    Gastaldi, Giorgio
    Gherlone, Enrico
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 120 (05): : 706 - 714
  • [40] Relationship between dental implant stability determined by resonance frequency analysis measurements and peri-implant vertical defects:: an in vitro study
    Tozum, T. F.
    Turkyilmaz, I.
    McGlumphy, E. A.