Study to assess the relationship between insertion torque value and implant stability quotient and its influence on timing of functional implant loading

被引:13
|
作者
Sarfaraz, Hasan [1 ]
Johri, Shefali [2 ]
Sucheta, P. [1 ]
Rao, Sripathi [2 ]
机构
[1] Yenepoya Dent Coll, Dept Prosthodont & Crown & Bridge, Univ Rd, Mangalore 575018, Karnataka, India
[2] Yenepoya Dent Coll, Dept Oral & Maxillofacial Surg, Mangalore, Karnataka, India
来源
关键词
Implant stability quotient; insertion torque value; Osstell-implant stability quotient device; primary stability; resonance frequency analysis; secondary stability; time of loading implants;
D O I
10.4103/jips.jips_203_17
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: One of the crucial requirements for the success of implants is to achieve good stability. Two well-accepted quantitative methods to assess implant stability, the insertion torque value (ITV), and resonance frequency analysis (RFA) can be a valuable adjunct to radiological and clinical examination. This study was conducted to assess the relationship between ITVs and implant stability quotient (ISQ) and its influence on timing of functional implant loading, as well as to determine the effect of some of the factors on the stability of implants. Materials and Methods: Forty implants were inserted in 37 patients in the posterior mandibular region according to conventional protocol and allowed to heal by placing a healing abutment at the time of placement. For each implant, ITV was measured at the time of the implant placement by manual torque wrench (Nobel Biocare), and the ISQ value was measured by using resonance frequency analyzer (Osstell-ISQ; Integration Diagnostics) at the baseline levels, 3rd week, 7th week, 11th week, and 15th week interval. Results: The correlation between ITV and ISQ was found to be moderately positive and significant (r = 0.399) (P = 0.000). The correlation of ITV value at baseline and ISQ values recorded at the subsequent weeks was also found to be statistically significant at week 3 (r = 0.376) (P = 0.000) and week 7 (r = 0.327) (P = 0.000). Conclusion: It can be concluded from this study that there is a positive and statistically significant correlation between the ITV and ISQ values.
引用
收藏
页码:139 / 146
页数:8
相关论文
共 50 条
  • [41] Influence of Implant Geometry on Primary Insertion Stability and Simulated Pen-implant Bone Loss: An In Vitro Study Using Resonance Frequency Analysis and Damping Capacity Assessment
    Lachmann, Stefan
    Laval, Johannes Yves
    Axmann, Detlef
    Weber, Heiner
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (02) : 347 - 355
  • [42] Correlation between insertion torque and peri-implant bone strain during placement of orthodontic mini-implants: A finite element study
    Hung, Bui Quang
    Yu, Wonjae
    Park, Hyo-Sang
    Kyung, Hee-Moon
    Hong, Mihee
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2022, 161 (02) : 248 - 254
  • [43] Relationship between Implant Geometry and Primary Stability in Different Bony Defects and Variant Bone Densities: An In Vitro Study
    Ibrahim, Ahmad
    Heitzer, Marius
    Bock, Anna
    Peters, Florian
    Moehlhenrich, Stephan Christian
    Hoelzle, Frank
    Modabber, Ali
    Kniha, Kristian
    MATERIALS, 2020, 13 (19) : 1 - 16
  • [44] Clinical study of the relationship between implant stability measurements using Periotest and Osstell mentor and bone quality assessment
    Oh, Ji-Su
    Kim, Su-Gwan
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2012, 113 (03): : E35 - E40
  • [45] FUNCTIONAL SCORE AND AESTHETIC VALUE OF DENTAL IMPLANT IN REPAIRING DENTITION DEFECT AND ITS INFLUENCE ON INFLAMMATORY INDEXES OF GINGIVAL CREVICULAR FLUID
    Zhang, Yanli
    Zhang, Baorong
    ACTA MEDICA MEDITERRANEA, 2019, 35 (03): : 1449 - 1453
  • [46] Influence of implant length and insertion depth on primary stability of short dental implants: An in vitro study of a novel mandibular artificial bone model
    Wu, Hsiang-Chun
    Huang, Heng-Li
    Fuh, Lih-Jyh
    Tsai, Ming-Tzu
    Hsu, Jui-Ting
    JOURNAL OF DENTAL SCIENCES, 2024, 19 (01) : 139 - 147
  • [47] A Four-Year Survival Rate Multicenter Prospective Clinical Study on 377 Implants: Correlations Between Implant Insertion Torque, Diameter, and Bone Quality
    Maiorana, Carlo
    Farronato, Davide
    Pieroni, Stefano
    Cicciu, Marco
    Andreoni, Dario
    Santoro, Franco
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (03) : E60 - E65
  • [48] Relationship between implant stability on the abutment and platform level by means of resonance frequency analysis: A cross-sectional study
    Lages, Frederico Santos
    Douglas-de-Oliveira, Dhelfeson Willya
    Ibelli, Guilherme Siqueira
    Assaf, Fatimah
    Queiroz, Thallita Pereira
    Costa, Fernando Oliveira
    PLOS ONE, 2017, 12 (07):
  • [49] Clinical measurement of implant stability using osstel at the time of fixture placement and after loading in maxilla and mandible: Correlations between fixture length and its stability.
    Tsuboi, V.
    Miyamoto, I.
    Nonaka, T.
    Iizuka, T.
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : B392 - B392
  • [50] Two Alternative Surgical Techniques for Enhancing Primary Implant Stability in the Posterior Maxilla: A Clinical Study Including Bone Density, Insertion Torque, and Resonance Frequency Analysis Data
    Turkyilmaz, Ilser
    Aksoy, Utku
    McGlumphy, Edwin A.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2008, 10 (04) : 231 - 237