Study to assess the relationship between insertion torque value and implant stability quotient and its influence on timing of functional implant loading

被引:13
|
作者
Sarfaraz, Hasan [1 ]
Johri, Shefali [2 ]
Sucheta, P. [1 ]
Rao, Sripathi [2 ]
机构
[1] Yenepoya Dent Coll, Dept Prosthodont & Crown & Bridge, Univ Rd, Mangalore 575018, Karnataka, India
[2] Yenepoya Dent Coll, Dept Oral & Maxillofacial Surg, Mangalore, Karnataka, India
来源
关键词
Implant stability quotient; insertion torque value; Osstell-implant stability quotient device; primary stability; resonance frequency analysis; secondary stability; time of loading implants;
D O I
10.4103/jips.jips_203_17
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: One of the crucial requirements for the success of implants is to achieve good stability. Two well-accepted quantitative methods to assess implant stability, the insertion torque value (ITV), and resonance frequency analysis (RFA) can be a valuable adjunct to radiological and clinical examination. This study was conducted to assess the relationship between ITVs and implant stability quotient (ISQ) and its influence on timing of functional implant loading, as well as to determine the effect of some of the factors on the stability of implants. Materials and Methods: Forty implants were inserted in 37 patients in the posterior mandibular region according to conventional protocol and allowed to heal by placing a healing abutment at the time of placement. For each implant, ITV was measured at the time of the implant placement by manual torque wrench (Nobel Biocare), and the ISQ value was measured by using resonance frequency analyzer (Osstell-ISQ; Integration Diagnostics) at the baseline levels, 3rd week, 7th week, 11th week, and 15th week interval. Results: The correlation between ITV and ISQ was found to be moderately positive and significant (r = 0.399) (P = 0.000). The correlation of ITV value at baseline and ISQ values recorded at the subsequent weeks was also found to be statistically significant at week 3 (r = 0.376) (P = 0.000) and week 7 (r = 0.327) (P = 0.000). Conclusion: It can be concluded from this study that there is a positive and statistically significant correlation between the ITV and ISQ values.
引用
收藏
页码:139 / 146
页数:8
相关论文
共 50 条
  • [21] Clinical study to assess influence of immediate provisionalization and various implant morphologies on implant stability: A prospective clinical study
    Qi, Meiyao
    Deng, Shiyong
    Tan, Zhen
    FRONTIERS IN SURGERY, 2023, 9
  • [22] Relation between insertion torque and bone–implant contact percentage: an artificial bone study
    Cheng Liu
    Ming-Tzu Tsai
    Heng-Li Huang
    Michael Yuan-Chien Chen
    Jui-Ting Hsu
    Kuo-Chih Su
    Chih-Han Chang
    Aaron Yu-Jen Wu
    Clinical Oral Investigations, 2012, 16 : 1679 - 1684
  • [23] Relationship between the CT Value and Cortical Bone Thickness at Implant Recipient Sites and Primary Implant Stability with Comparison of Different Implant Types
    Howashi, Miori
    Tsukiyama, Yoshihiro
    Ayukawa, Yasunori
    Isoda-Akizuki, Kei
    Kihara, Masafumi
    Imai, Yu
    Sogo, Motofumi
    Koyano, Kiyoshi
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (01) : 107 - 116
  • [24] IMPLANT STABILITY RELATED TO INSERTION TORQUE FORCE AND BONE-DENSITY - AN IN-VITRO STUDY
    TRICIO, J
    VANSTEENBERGHE, D
    ROSENBERG, D
    DUCHATEAU, L
    JOURNAL OF PROSTHETIC DENTISTRY, 1995, 74 (06): : 608 - 612
  • [25] Analysis of the relationship between a modified method for implant site preparation and primary implant stability: A pilot study
    Unsal, Gokce Soganci
    Turkyilmaz, Ilser
    JOURNAL OF DENTAL SCIENCES, 2020, 15 (02) : 234 - 235
  • [26] Relation between insertion torque and bone-implant contact percentage: an artificial bone study
    Liu, Cheng
    Tsai, Ming-Tzu
    Huang, Heng-Li
    Chen, Michael Yuan-Chien
    Hsu, Jui-Ting
    Su, Kuo-Chih
    Chang, Chih-Han
    Wu, Aaron Yu-Jen
    CLINICAL ORAL INVESTIGATIONS, 2012, 16 (06) : 1679 - 1684
  • [27] The Influence of Low Insertion Torque on Primary Stability, Implant Survival, and Maintenance of Marginal Bone Levels: A Closed-Cohort Prospective Study
    Norton, Michael R.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) : 849 - 857
  • [28] Mathematical evaluation of the influence of multiple factors on implant stability quotient values in clinical practice: a retrospective study
    Huang, Hairong
    Wismeijer, Daniel
    Shao, Xianhong
    Wu, Gang
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2016, 12 : 1525 - 1532
  • [29] Correlation between Implant Geometry, Bone Density, and the Insertion Torque/Depth Integral: A Study on Bovine Ribs
    Di Stefano, Danilo Alessio
    Arosio, Paolo
    Perrotti, Vittoria
    Iezzi, Giovanna
    Scarano, Antonio
    Piattelli, Adriano
    DENTISTRY JOURNAL, 2019, 7 (01)
  • [30] Relationship between Implant Length and Implant Stability of Single-Implant Restorations: A 12-Month Follow-Up Clinical Study
    Aragoneses, Juan Manuel
    Aragoneses, Javier
    Brugal, Vanessa Arlette
    Gomez, Margarita
    Suarez, Ana
    MEDICINA-LITHUANIA, 2020, 56 (06):