Randomized Clinical Trial Comparing Insertion Torque and Implant Stability of Two Different Implant Macrogeometries in the Initial Periods of Osseointegration

被引:11
|
作者
Gehrke, Sergio Alexandre [1 ,2 ,3 ,4 ]
Cortellari, Guillermo Castro [1 ]
Fernandes, Gustavo Vicentis de Oliveira [5 ]
Scarano, Antonio [1 ,6 ]
Martins, Rafael Garcia [7 ]
Cancado, Renata Moreira [7 ]
Mesquita, Alfredo Mikail Melo [7 ]
机构
[1] UCAM, Dept Res, Bioface PgO, Calle Cuareim 1483, Montevideo 11100, Uruguay
[2] Univ Miguel Hernandez, Inst Bioingn, Avda Ferrocarril S-N, Elche 03202, Spain
[3] Univ Catol Murcia UCAM, Dept Biotechnol, Murcia 30107, Spain
[4] Pontificia Univ Catolica Rio Grande do Sul, Dept Mat Engn, BR-90619900 Porto Alegre, Brazil
[5] Univ Michigan, Periodont & Oral Med Dept, Sch Dent, Ann Arbor, MI 48109 USA
[6] Univ G dAnnunzio, Dept Innovat Technol Med & Dent, I-66100 Chieti, Italy
[7] Paulista Univ UNIP, Dept Implantol, BR-04026002 Sao Paulo, Brazil
来源
MEDICINA-LITHUANIA | 2023年 / 59卷 / 01期
关键词
clinical study; implant macrogeometry; implant stability; insertion torque; resonance frequency analysis; RESONANCE FREQUENCY-ANALYSIS; DENTAL IMPLANTS; CORTICAL BONE; DESIGN; DIMENSION; CONTACT;
D O I
10.3390/medicina59010168
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The present study compared two implants with different macrogeometries placed in healed alveolar sites, evaluating the insertion torque (ITV) and implant stability quotient (ISQ) values at three different periods. Methods: Seventy patients with a total of 100 dental implants were allocated into two groups (n = 50 per group): DuoCone implants (DC group) that included 28 implants in the maxilla and 22 in the mandible, and Maestro implants (MAE group) that included 26 in the maxilla and 24 in the mandible. The ITV was measured during the implant placement, and the ISQ values were measured immediately at implant placement (baseline) and after 30 and 45 days. Results: The mean and standard deviations of the ITV were statistically significant (p < 0.0001), 56.4 +/- 6.41 Ncm for the DC group and 29.3 +/- 9.65 Ncm for the MAE group. In the DC group, the ISQs ranged between 61.1 +/- 3.78 and 69.8 +/- 3.86, while the MAE group presented similar values compared with the other group, ranging between 61.9 +/- 3.92 and 72.1 +/- 2.37. Conclusions: The value of implant insertion torque did not influence the ISQ values measured immediately after implant placement. However, the ITV influenced the ISQ values measured in the two initial periods of osseointegration, with implants installed with lower torques presenting higher ISQ values.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Can implant surfaces affect implant stability during osseointegration? A randomized clinical trial
    do Carmo Filho, Luiz Carlos
    Marcello-Machado, Raissa Micaella
    de Castilhos, Eduardo Dickie
    Del Bel Cury, Altair Antoninha
    Faot, Fernanda
    BRAZILIAN ORAL RESEARCH, 2018, 32
  • [2] Implant Stability and Histomorphometric Analysis Comparing Two Different Implant Macrogeometries Placed in Fresh Sockets: An Experimental Study in Sheep
    Gehrke, Sergio Alexandre
    Aramburil Junior, Jaime
    Treichel, Tiago Luis Eirles
    da Costa, Eleani Maria
    Scarano, Antonio
    De Bortoli Junior, Nilton
    Fernandes, Gustavo Vicentis Oliveira
    De Aza, Piedad N.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (06) : 857 - 866
  • [3] Randomized Clinical Trial: Bone Bioactive Liquid Improves Implant Stability and Osseointegration
    Al Madhoun, Ashraf
    Meshal, Khaled
    Carrio, Neus
    Ferres-Amat, Eduard
    Ferres-Amat, Elvira
    Barajas, Miguel
    Jimenez-Escobar, Ana Leticia
    Al-Madhoun, Areej Said
    Saber, Alaa
    Abou Alsamen, Yazan
    Marti, Carles
    Atari, Maher
    JOURNAL OF FUNCTIONAL BIOMATERIALS, 2024, 15 (10)
  • [4] Insertion Torque Value and Implant Stability Quotient: Separate Evaluation and Correlation for Different Clinical Parameters
    Ferreira, Jose Joaquim Da Rocha
    Machado, Luis Filipe Meira
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 812 - 822
  • [5] Prospective randomized clinical trial evaluating the effects of two different implant collar designs on peri-implant healing and functional osseointegration after 25 years
    Camarda, Aldo Joseph
    Durand, Robert
    Benkarim, Marwa
    Rompre, Pierre H.
    Guertin, Genevieve
    Ciaburro, Hugo
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (03) : 285 - 296
  • [6] Influence of torque and bone type on stability quotient of two implant platforms: a clinical trial
    Bannwart, Lisiane Cristina
    dos Santos, Daniela Micheline
    Souza, Joao Paulo do Vale
    Neto, Clovis Lamartine de Moraes M. E. L. O.
    da Silva, Emily Vivianne Freitas
    Mazaro, Jose Vitor Quinelli
    Salzedas, Leda Maria Piscinini
    Goiato, Marcelo Coelho
    BRAZILIAN ORAL RESEARCH, 2024, 38
  • [7] A Randomized Controlled Clinical Trial Comparing the Effects of Three Loading Protocols on Dental Implant Stability
    Barewal, Reva M.
    Stanford, Clark
    Weesner, Ted C.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (04) : 945 - 956
  • [8] Impact of Insertion Torque and Implant Neck Design on Peri-Implant Bone Level: A Randomized Split-Mouth Trial
    Hof, Markus
    Pommer, Bernhard
    Strbac, Georg D.
    Vasak, Christoph
    Agis, Hermann
    Zechner, Werner
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (05) : 668 - 674
  • [9] Effect of ultraviolet photofunctionalization on implant stability and osseointegration: a randomized controlled trial of UVA and UVC on SLA-coated titanium implant
    Zaheer, Naauman
    Shahbaz, Maliha
    Zaheer, Usman
    Rajion, Zainul Ahmad Bin
    Zaigha, Abdul Moeed
    Saeed, Muhammad Qasim
    KHYBER MEDICAL UNIVERSITY JOURNAL-KMUJ, 2024, 16 (04): : 314 - 321
  • [10] Influence of implant design, length, diameter, and anatomic region on implant stability: a randomized clinical trial
    Moreira, Andre
    Rosa, Jose
    Freitas, Filipe
    Francisco, Helena
    Luis, Henrique
    Carames, Joao
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2021, 62 (01): : 9 - 15