共 50 条
Randomized Clinical Trial Comparing Insertion Torque and Implant Stability of Two Different Implant Macrogeometries in the Initial Periods of Osseointegration
被引:11
|作者:
Gehrke, Sergio Alexandre
[1
,2
,3
,4
]
Cortellari, Guillermo Castro
[1
]
Fernandes, Gustavo Vicentis de Oliveira
[5
]
Scarano, Antonio
[1
,6
]
Martins, Rafael Garcia
[7
]
Cancado, Renata Moreira
[7
]
Mesquita, Alfredo Mikail Melo
[7
]
机构:
[1] UCAM, Dept Res, Bioface PgO, Calle Cuareim 1483, Montevideo 11100, Uruguay
[2] Univ Miguel Hernandez, Inst Bioingn, Avda Ferrocarril S-N, Elche 03202, Spain
[3] Univ Catol Murcia UCAM, Dept Biotechnol, Murcia 30107, Spain
[4] Pontificia Univ Catolica Rio Grande do Sul, Dept Mat Engn, BR-90619900 Porto Alegre, Brazil
[5] Univ Michigan, Periodont & Oral Med Dept, Sch Dent, Ann Arbor, MI 48109 USA
[6] Univ G dAnnunzio, Dept Innovat Technol Med & Dent, I-66100 Chieti, Italy
[7] Paulista Univ UNIP, Dept Implantol, BR-04026002 Sao Paulo, Brazil
来源:
关键词:
clinical study;
implant macrogeometry;
implant stability;
insertion torque;
resonance frequency analysis;
RESONANCE FREQUENCY-ANALYSIS;
DENTAL IMPLANTS;
CORTICAL BONE;
DESIGN;
DIMENSION;
CONTACT;
D O I:
10.3390/medicina59010168
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Objectives: The present study compared two implants with different macrogeometries placed in healed alveolar sites, evaluating the insertion torque (ITV) and implant stability quotient (ISQ) values at three different periods. Methods: Seventy patients with a total of 100 dental implants were allocated into two groups (n = 50 per group): DuoCone implants (DC group) that included 28 implants in the maxilla and 22 in the mandible, and Maestro implants (MAE group) that included 26 in the maxilla and 24 in the mandible. The ITV was measured during the implant placement, and the ISQ values were measured immediately at implant placement (baseline) and after 30 and 45 days. Results: The mean and standard deviations of the ITV were statistically significant (p < 0.0001), 56.4 +/- 6.41 Ncm for the DC group and 29.3 +/- 9.65 Ncm for the MAE group. In the DC group, the ISQs ranged between 61.1 +/- 3.78 and 69.8 +/- 3.86, while the MAE group presented similar values compared with the other group, ranging between 61.9 +/- 3.92 and 72.1 +/- 2.37. Conclusions: The value of implant insertion torque did not influence the ISQ values measured immediately after implant placement. However, the ITV influenced the ISQ values measured in the two initial periods of osseointegration, with implants installed with lower torques presenting higher ISQ values.
引用
收藏
页数:15
相关论文