Randomized Clinical Trial Comparing Insertion Torque and Implant Stability of Two Different Implant Macrogeometries in the Initial Periods of Osseointegration

被引:11
|
作者
Gehrke, Sergio Alexandre [1 ,2 ,3 ,4 ]
Cortellari, Guillermo Castro [1 ]
Fernandes, Gustavo Vicentis de Oliveira [5 ]
Scarano, Antonio [1 ,6 ]
Martins, Rafael Garcia [7 ]
Cancado, Renata Moreira [7 ]
Mesquita, Alfredo Mikail Melo [7 ]
机构
[1] UCAM, Dept Res, Bioface PgO, Calle Cuareim 1483, Montevideo 11100, Uruguay
[2] Univ Miguel Hernandez, Inst Bioingn, Avda Ferrocarril S-N, Elche 03202, Spain
[3] Univ Catol Murcia UCAM, Dept Biotechnol, Murcia 30107, Spain
[4] Pontificia Univ Catolica Rio Grande do Sul, Dept Mat Engn, BR-90619900 Porto Alegre, Brazil
[5] Univ Michigan, Periodont & Oral Med Dept, Sch Dent, Ann Arbor, MI 48109 USA
[6] Univ G dAnnunzio, Dept Innovat Technol Med & Dent, I-66100 Chieti, Italy
[7] Paulista Univ UNIP, Dept Implantol, BR-04026002 Sao Paulo, Brazil
来源
MEDICINA-LITHUANIA | 2023年 / 59卷 / 01期
关键词
clinical study; implant macrogeometry; implant stability; insertion torque; resonance frequency analysis; RESONANCE FREQUENCY-ANALYSIS; DENTAL IMPLANTS; CORTICAL BONE; DESIGN; DIMENSION; CONTACT;
D O I
10.3390/medicina59010168
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The present study compared two implants with different macrogeometries placed in healed alveolar sites, evaluating the insertion torque (ITV) and implant stability quotient (ISQ) values at three different periods. Methods: Seventy patients with a total of 100 dental implants were allocated into two groups (n = 50 per group): DuoCone implants (DC group) that included 28 implants in the maxilla and 22 in the mandible, and Maestro implants (MAE group) that included 26 in the maxilla and 24 in the mandible. The ITV was measured during the implant placement, and the ISQ values were measured immediately at implant placement (baseline) and after 30 and 45 days. Results: The mean and standard deviations of the ITV were statistically significant (p < 0.0001), 56.4 +/- 6.41 Ncm for the DC group and 29.3 +/- 9.65 Ncm for the MAE group. In the DC group, the ISQs ranged between 61.1 +/- 3.78 and 69.8 +/- 3.86, while the MAE group presented similar values compared with the other group, ranging between 61.9 +/- 3.92 and 72.1 +/- 2.37. Conclusions: The value of implant insertion torque did not influence the ISQ values measured immediately after implant placement. However, the ITV influenced the ISQ values measured in the two initial periods of osseointegration, with implants installed with lower torques presenting higher ISQ values.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] A randomized clinical trial on the accuracy of guided implant surgery between two implant-planning programs used by inexperienced operators
    Singthong, Wanwanat
    Serichetaphongse, Pravej
    Chengprapakorn, Wareeratn
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 131 (03): : 436 - 442
  • [32] A preliminary randomized clinical trial comparing diode laser and scalpel periosteal incision during implant surgery: impact on postoperative morbidity and implant survival
    Aysan Shahnaz
    Raika Jamali
    Farnush Mohammadi
    Afshin Khorsand
    Neda Moslemi
    Reza Fekrazad
    Lasers in Medical Science, 2018, 33 : 19 - 25
  • [33] A preliminary randomized clinical trial comparing diode laser and scalpel periosteal incision during implant surgery: impact on postoperative morbidity and implant survival
    Shahnaz, Aysan
    Jamali, Raika
    Mohammadi, Farnush
    Khorsand, Afshin
    Moslemi, Neda
    Fekrazad, Reza
    LASERS IN MEDICAL SCIENCE, 2018, 33 (01) : 19 - 25
  • [34] Comparison of two different surgical approaches to increase peri-implant mucosal thickness: A randomized controlled clinical trial
    Hutton, Christopher G.
    Johnson, Georgia K.
    Barwacz, Christopher A.
    Allareddy, Veerasathpurush
    Avila-Ortiz, Gustavo
    JOURNAL OF PERIODONTOLOGY, 2018, 89 (07) : 807 - 814
  • [35] A Randomized Case-Series Study Comparing the Stability of Implant with Two Different Surfaces Placed in Fresh Extraction Sockets and Immediately Loaded
    Bogaerde, Leonardo Vanden
    Sennerby, Lars
    INTERNATIONAL JOURNAL OF DENTISTRY, 2016, 2016
  • [36] Multicenter Clinical Randomized Controlled Trial Evaluation of an Implant System Designed for Enhanced Primary Stability
    Stanford, Clark M.
    Barwacz, Chris
    Raes, Stephanie
    De Bruyn, Hugo
    Cecchinato, Denis
    Bittner, Nurit
    Brandt, Jan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (04) : 906 - 915
  • [37] Effectiveness of Photobiomodulation With Low-Level Laser Therapy on the Implant Stability Quotient at Different Time Intervals: A Randomized Clinical Trial
    Shenoy, Amrutha
    Ganapathy, Dhanraj
    Maiti, Subhabrata
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [38] Relationship between implant primary stability (torque and ISQ) and bone density assessed by CBCT-clinical trial
    Gomes, R. Z.
    Lopes da Silva, L.
    Coimbra, J.
    Guerra, I.
    Vasconcelos, M.
    Correia, A.
    Braga, A. C.
    BIODENTAL ENGINEERING III, 2014, : 125 - 130
  • [39] A randomized controlled clinical trial comparing guided with nonguided implant placement: A 3-year follow-up of implant-centered outcomes
    Bernard, Lauren
    Vercruyssen, Marjolein
    Duyck, Joke
    Jacobs, Reinhilde
    Teughels, Wim
    Quirynen, Marc
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (06): : 904 - 910
  • [40] A randomized controlled clinical trial to assess crestal bone remodeling of four different implant designs
    Glibert, Maarten
    Vervaeke, Stijn
    Jacquet, Wolfgang
    Vermeersch, Kim
    Ostman, Par-Olov
    De Bruyn, Hugo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (04) : 455 - 462