The Sit-to-Stand Transition as a Biomarker for Impairment: Comparison of Instrumented 30-Second Chair Stand Test and Daily Life Transitions in Multiple Sclerosis

被引:13
|
作者
Tulipani, Lindsey J. [1 ]
Meyer, Brett [1 ]
Fox, Samantha [1 ]
Solomon, Andrew J. [2 ]
Mcginnis, Ryan S. [1 ]
机构
[1] Univ Vermont, Dept Elect & Biomed Engn, Burlington, VT 05405 USA
[2] Univ Vermont, Dept Neurol Sci, Burlington, VT 05405 USA
关键词
Wearable; accelerometer; sit-to-stand; multiple sclerosis; falls; FALL RISK; MOBILITY IMPAIRMENT; PARKINSONS-DISEASE; BALANCE; PEOPLE; SENSOR; GAIT; VALIDATION; STRENGTH; METRICS;
D O I
10.1109/TNSRE.2022.3169962
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Falls and mobility deficits are common in people with multiple sclerosis (PwMS) across all levels of clinical disability. However, functional mobility observed in supervised settings may not reflect daily life which may impact assessments of fall risk and impairment in the clinic. To investigate this further, we compared the utility of sensor-based performance metrics from sit-stand transitions during daily life and a structured task to inform fall risk and impairment in PwMS. Thirty-seven PwMS instrumented with wearable sensors (thigh and chest) completed supervised 30-second chair stand tests (30CST) and underwent two days of instrumented daily life monitoring. Performance metrics were computed for sit-stand transitions during daily life and 30CSTs. EDSS sub scores and fall history were used to dichotomize participants into groups: pyramidal/no pyramidal impairment, sensory/no sensory impairment and high/low fall risk. The ability of performance metrics to discriminate between groups was assessed using the area under the curve (AUC). The feature that best discriminated between high and low fall risk was a chest acceleration measurement from the supervised instrumented 30CST (AUC = 0.89). Only chest features indicated sensory impairment, however the task was different between supervised and daily life. The metric that best discriminated pyramidal impairment was a chest-derived feature (AUC = 0.89) from supervised 30CSTs. The highest AUC from daily life was observed in faller classification with the average sit-stand time (0.81). While characterizing sit-stand performance during daily life may yield insights into fall risk and may be performed without a clinic visit, there remains value to conducting supervised functional assessments to provide the best classification performance between the investigated impairments in this sample.
引用
收藏
页码:1213 / 1222
页数:10
相关论文
共 44 条
  • [31] Test-retest reliability and validity of the timed up and go test and 30-second sit to stand test in patients with pulmonary hypertension
    Kahraman, Buse Ozcan
    Ozsoy, Ismail
    Akdeniz, Bahri
    Ozpelit, Ebru
    Sevinc, Can
    Acar, Serap
    Savci, Sema
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 304 : 159 - 163
  • [32] Minimal clinically important difference in 30 second sit-to-stand test after pulmonary rehabilitation in patients with COPD
    Zanini, Andrea
    Crisafulli, Ernesto
    D'Andria, Michele
    Gregorini, Cristina
    Cherubino, Francesca
    Zampogna, Elisabetta
    Azzola, Andrea
    Spanevello, Antonio
    Chetta, Alfredo
    EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [33] Fall risk screening in the elderly: A comparison of the minimal chair height standing ability test and 5-repetition sit-to-stand test
    Reider, Nadia
    Gaul, Catherine
    ARCHIVES OF GERONTOLOGY AND GERIATRICS, 2016, 65 : 133 - 139
  • [34] Transitioning Assessments from the Clinic to Daily Life: Exploring Sit-to-Stand Transition Rates As a Means for Assessing Symptom Fluctuation
    Tulipani, Lindsey J.
    Adamowicz, Lukas
    Gurchiek, Reed D.
    Weed, Lara
    Warren, Haley
    Solomon, Andrew J.
    McGinnis, Ryan S.
    MULTIPLE SCLEROSIS JOURNAL, 2019, 25 : 43 - 44
  • [35] THE USEFULNESS OF A 30-SECOND CHAIR STAND TEST FOR EVALUATING EXERCISE CAPACITY IN PATIENTS WITH MILD-TO-MODERATE INTERSTITIAL LUNG DISEASE
    Ishihara, Atsushi
    Taga, Shu
    Nakatake, Hitoshi
    Nakamura, Satsuki
    Miyahara, Toshihiro
    Kou, Takashi
    Itoh, Shinichi
    Nishiyama, Osamu
    RESPIROLOGY, 2013, 18 : 136 - 136
  • [36] Test-retest reliability of the 50-foot timed walk and 30-second chair stand test in patients with total hip arthroplasty
    Unver, Bayram
    Kahraman, Turhan
    Kalkan, Serpil
    Yuksel, Ertugrul
    Karatosun, Vasfi
    Gunal, Izge
    ACTA ORTHOPAEDICA BELGICA, 2015, 81 (03): : 435 - 441
  • [37] The 30-second chair stand test (CS30) as a predictor of exercise tolerance in elderly individuals (≥75 years) with stage A/B heart failure
    Kobayashi, Taku
    Iwasaki, Takatoshi
    Kurata, Hiroko
    Nikaido, Akira
    Hata, Yoshiki
    IJC HEART & VASCULATURE, 2024, 53
  • [38] Exercise capacity prior to major cancer surgery: A cross-sectional observational study of the validity of the 6-minute walk and 30-second sit-to-stand tests
    Butson, Grace
    Edbrooke, Lara
    Ismail, Hilmy
    Denehy, Linda
    ASIA-PACIFIC JOURNAL OF CLINICAL ONCOLOGY, 2024, 20 (04) : 497 - 506
  • [39] iPhone Sensors in Tracking Outcome Variables of the 30-Second Chair Stand Test and Stair Climb Test to Evaluate Disability: Cross-Sectional Pilot Study
    Adusumilli, Gautam
    Joseph, Solomon Eben
    Samaan, Michael A.
    Schultz, Brooke
    Popovic, Tijana
    Souza, Richard B.
    Majumdar, Sharmila
    JMIR MHEALTH AND UHEALTH, 2017, 5 (10):
  • [40] Self-assessment using 30-second chair stand test for patients with knee osteoarthritis - an intra- and inter-rater reliability study
    Ho-Henriksson, Chan-Mei
    Thorstensson, Carina A.
    Nordeman, Lena
    EUROPEAN JOURNAL OF PHYSIOTHERAPY, 2024,