The Sit-to-Stand Transition as a Biomarker for Impairment: Comparison of Instrumented 30-Second Chair Stand Test and Daily Life Transitions in Multiple Sclerosis

被引:13
|
作者
Tulipani, Lindsey J. [1 ]
Meyer, Brett [1 ]
Fox, Samantha [1 ]
Solomon, Andrew J. [2 ]
Mcginnis, Ryan S. [1 ]
机构
[1] Univ Vermont, Dept Elect & Biomed Engn, Burlington, VT 05405 USA
[2] Univ Vermont, Dept Neurol Sci, Burlington, VT 05405 USA
关键词
Wearable; accelerometer; sit-to-stand; multiple sclerosis; falls; FALL RISK; MOBILITY IMPAIRMENT; PARKINSONS-DISEASE; BALANCE; PEOPLE; SENSOR; GAIT; VALIDATION; STRENGTH; METRICS;
D O I
10.1109/TNSRE.2022.3169962
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Falls and mobility deficits are common in people with multiple sclerosis (PwMS) across all levels of clinical disability. However, functional mobility observed in supervised settings may not reflect daily life which may impact assessments of fall risk and impairment in the clinic. To investigate this further, we compared the utility of sensor-based performance metrics from sit-stand transitions during daily life and a structured task to inform fall risk and impairment in PwMS. Thirty-seven PwMS instrumented with wearable sensors (thigh and chest) completed supervised 30-second chair stand tests (30CST) and underwent two days of instrumented daily life monitoring. Performance metrics were computed for sit-stand transitions during daily life and 30CSTs. EDSS sub scores and fall history were used to dichotomize participants into groups: pyramidal/no pyramidal impairment, sensory/no sensory impairment and high/low fall risk. The ability of performance metrics to discriminate between groups was assessed using the area under the curve (AUC). The feature that best discriminated between high and low fall risk was a chest acceleration measurement from the supervised instrumented 30CST (AUC = 0.89). Only chest features indicated sensory impairment, however the task was different between supervised and daily life. The metric that best discriminated pyramidal impairment was a chest-derived feature (AUC = 0.89) from supervised 30CSTs. The highest AUC from daily life was observed in faller classification with the average sit-stand time (0.81). While characterizing sit-stand performance during daily life may yield insights into fall risk and may be performed without a clinic visit, there remains value to conducting supervised functional assessments to provide the best classification performance between the investigated impairments in this sample.
引用
收藏
页码:1213 / 1222
页数:10
相关论文
共 44 条
  • [21] Validity and variability of the 5-repetition sit-to-stand test in patients with multiple sclerosis
    Moller, Andreas Buch
    Bibby, Bo Martin
    Skjerbaek, Anders Guldhammer
    Jensen, Ellen
    Sorensen, Henrik
    Stenager, Egon
    Dalgas, Ulrik
    DISABILITY AND REHABILITATION, 2012, 34 (26) : 2251 - 2258
  • [22] Thigh-Derived Inertial Sensor Metrics to Assess the Sit-to-Stand and Stand-to-Sit Transitions in the Timed Up and Go (TUG) Task for Quantifying Mobility Impairment in Multiple Sclerosis
    Witchel, Harry J.
    Oberndorfer, Caecilia
    Needham, Robert
    Healy, Aoife
    Westling, Carina E., I
    Guppy, Joseph H.
    Bush, Jake
    Barth, Jens
    Herberz, Chantal
    Roggen, Daniel
    Eskofier, Bjoern M.
    Rashid, Waciar
    Chockalingam, Nachiappan
    Klucken, Jochen
    FRONTIERS IN NEUROLOGY, 2018, 9
  • [23] The influence of chair seat height on the performance of community-dwelling older adults’ 30-second chair stand test
    Yi-Liang Kuo
    Aging Clinical and Experimental Research, 2013, 25 : 305 - 309
  • [24] The influence of chair seat height on the performance of community-dwelling older adults' 30-second chair stand test
    Kuo, Yi-Liang
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2013, 25 (03) : 305 - 309
  • [25] Association Between The 30-second Chair Stand Test And Single Limb Hop Tests In College Students
    Almutairi, Marzouq K.
    Alrashedy, Naif Z.
    Almutairi, Sattam M.
    Alotaibi, Mansour M.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2024, 56 (10) : 383 - 383
  • [26] Predicting exercise intolerance in elderly individuals with heart failure using the 30-second chair stand test
    Savino, Marco
    Savino, Luigi
    Mone, Pasquale
    Schiano, Concetta
    De Luca, Antonio
    Santulli, Gaetano
    IJC HEART & VASCULATURE, 2024, 53
  • [27] Normative Reference Values and Validity for the 30-Second Chair-Stand Test in Healthy Young Adults
    Lein, Donald H., Jr.
    Alotaibi, Mansour
    Almutairi, Marzouq
    Singh, Harshvardhan
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2022, 17 (05): : 907 - 914
  • [28] Significance of Preoperative Multidisciplinary Assessment with 30-Second Sit-to-Stand and Timed Up-and-Go Tests in Predicting Postoperative Outcomes
    Yucel, Mucahid Osman
    Saglam, Sonmez
    Dalaslan, Rasit Emin
    Arican, Mehmet
    Karaduman, Zekeriya Okan
    Akar, Bedrettin
    Celik, Mucahit
    Sav, Ismail
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (04)
  • [29] Intra- and inter-rater reproducibility of the 6-minute walk test and the 30-second sit-to-stand test in patients with severe and very severe COPD
    Hansen, Henrik
    Beyer, Nina
    Frolich, Anne
    Godtfredsen, Nina
    Bieler, Theresa
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2018, 13 : 3447 - 3457
  • [30] Validity and Responsiveness to Change of the 30-Second Chair-Stand Test in Older Adults Admitted to an Emergency Department
    Bruun, Inge Hansen
    Mogensen, Christian B.
    Norgaard, Birgitte
    Schiottz-Christensen, Berit
    Maribo, Thomas
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2019, 42 (04) : 265 - 274