The Sit-to-Stand Transition as a Biomarker for Impairment: Comparison of Instrumented 30-Second Chair Stand Test and Daily Life Transitions in Multiple Sclerosis

被引:13
|
作者
Tulipani, Lindsey J. [1 ]
Meyer, Brett [1 ]
Fox, Samantha [1 ]
Solomon, Andrew J. [2 ]
Mcginnis, Ryan S. [1 ]
机构
[1] Univ Vermont, Dept Elect & Biomed Engn, Burlington, VT 05405 USA
[2] Univ Vermont, Dept Neurol Sci, Burlington, VT 05405 USA
关键词
Wearable; accelerometer; sit-to-stand; multiple sclerosis; falls; FALL RISK; MOBILITY IMPAIRMENT; PARKINSONS-DISEASE; BALANCE; PEOPLE; SENSOR; GAIT; VALIDATION; STRENGTH; METRICS;
D O I
10.1109/TNSRE.2022.3169962
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Falls and mobility deficits are common in people with multiple sclerosis (PwMS) across all levels of clinical disability. However, functional mobility observed in supervised settings may not reflect daily life which may impact assessments of fall risk and impairment in the clinic. To investigate this further, we compared the utility of sensor-based performance metrics from sit-stand transitions during daily life and a structured task to inform fall risk and impairment in PwMS. Thirty-seven PwMS instrumented with wearable sensors (thigh and chest) completed supervised 30-second chair stand tests (30CST) and underwent two days of instrumented daily life monitoring. Performance metrics were computed for sit-stand transitions during daily life and 30CSTs. EDSS sub scores and fall history were used to dichotomize participants into groups: pyramidal/no pyramidal impairment, sensory/no sensory impairment and high/low fall risk. The ability of performance metrics to discriminate between groups was assessed using the area under the curve (AUC). The feature that best discriminated between high and low fall risk was a chest acceleration measurement from the supervised instrumented 30CST (AUC = 0.89). Only chest features indicated sensory impairment, however the task was different between supervised and daily life. The metric that best discriminated pyramidal impairment was a chest-derived feature (AUC = 0.89) from supervised 30CSTs. The highest AUC from daily life was observed in faller classification with the average sit-stand time (0.81). While characterizing sit-stand performance during daily life may yield insights into fall risk and may be performed without a clinic visit, there remains value to conducting supervised functional assessments to provide the best classification performance between the investigated impairments in this sample.
引用
收藏
页码:1213 / 1222
页数:10
相关论文
共 44 条
  • [41] The test-retest reliability and minimal detectable change of the six-minute walk test, timed up and go test, and 30-second chair stand test in people with epilepsy
    Aktar, Burcin
    Balci, Birgul
    Oztura, Ibrahim
    Baklan, Baris
    PHYSIOTHERAPY THEORY AND PRACTICE, 2024, 40 (10)
  • [42] The 30-s sit-to-stand power test is a better tool than isometric knee extensor torque to assess motor impairment in people with haemophilic arthropathy
    Cruz-Montecinos, Carlos
    Moena-Leon, Maria
    Duran-Ovalle, Antonio
    Lizama-Jofre, Aracelli
    Soto, Veronica
    Oyarzun, Andres
    Nunez-Cortes, Rodrigo
    Tapia, Claudio
    Daffunchio, Carla
    HAEMOPHILIA, 2024, 30 : 116 - 117
  • [43] Metrics extracted from a single wearable sensor during sit-stand transitions relate to mobility impairment and fall risk in people with multiple sclerosis
    Tulipani, Lindsey J.
    Meyer, Brett
    Larie, Dale
    Solomon, Andrew J.
    McGinnis, Ryan S.
    GAIT & POSTURE, 2020, 80 : 361 - 366
  • [44] Validity of the 30-Second Chair-Stand Test to Assess Exercise Tolerance and Clinical Outcomes in Patients with Esophageal Cancer: A Retrospective Study with Reference to 6-Minute Walk Test Results
    Ikeda, Tomohiro
    Noma, Kazuhiro
    Okura, Kazuki
    Katayama, Sho
    Takahashi, Yusuke
    Maeda, Naoaki
    Tanabe, Shunsuke
    Wakita, Akiyuki
    Hamada, Masanori
    Fujiwara, Toshiyoshi
    Senda, Masuo
    ACTA MEDICA OKAYAMA, 2023, 77 (02) : 193 - 197