Self-assessment using 30-second chair stand test for patients with knee osteoarthritis - an intra- and inter-rater reliability study

被引:3
|
作者
Ho-Henriksson, Chan-Mei [1 ,2 ]
Thorstensson, Carina A. [2 ,3 ]
Nordeman, Lena [2 ,4 ]
机构
[1] Narhalsan Lidkoping Rehabmottagning, Reg Vastra Gotaland, Primary Care Rehabil, Lidkoping, Sweden
[2] Univ Gothenburg, Dept Hlth & Rehabil, Unit Physiotherapy, Inst Neurosci & Physiol,Sahlgrenska Acad, Gothenburg, Sweden
[3] Reg Halland, Res & Dev Ctr, Halmstad, Sweden
[4] Reg Vastra Gotaland, Res Educ Dev & Innovat Primary Hlth Care, Res Educ Dev & Innovat Ctr Sodra Alvsborg, Boras, Sweden
关键词
self-assessment; physical function; physiotherapy; knee osteoarthritis; digital healthcare; minimal detectable change; cut-off value; PERFORMANCE-BASED TESTS; PHYSICAL-FUNCTION; RISK-FACTORS; HIP; PAIN; PEOPLE; LIMITATIONS; AGREEMENT;
D O I
10.1080/21679169.2024.2337419
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: We aimed to evaluate the intra-rater reliability in 30-second chair stand test (30CST) as a self-test, and the inter-rater reliability comparing a self-test with a physiotherapist-assessed 30CST for patients with knee osteoarthritis (KOA). The second purpose was to evaluate the classification ability of the 30CST as self-test to distinguish between reduced physical function and normal function. Methods: Patients with KOA performed two self-tests of 30CST at home and thereafter a physiotherapist assessed the patient. Absolute agreements were presented with intraclass correlation coefficient (ICC), 95% confidence interval (CI) and standard error of measurement (SEM). Post-hoc analyses were conducted to calculate minimal detectable change (MDC). The classification ability was analysed with receiver operating characteristic (ROC)-curves and area under the ROC-curve (AUC). The significance level was p < 0.05. Results: In total, 114 followed the protocol. Intra-rater and inter-rater reliability were good (ICC 0.97, CI 0.95-0.99, SEM 0.89 and ICC 0.81, CI 0.72-0.87, SEM 2.29 respectively). MDC were 2.5 stands when comparing self-test results individually and 0.23 on a group level. The MDC between self-tests and physiotherapist assessment were 6.4 stands for individual comparison and 0.59 for group comparison. The self-test was 80% likely to detect reduced physical function compared to a physiotherapist assessing physical function with 30CST (AUC = 0.79-0.80). Conclusions: The results indicate that 30CST can be a reliable self-assessment of physical function in lower extremities for patients with KOA. These findings can be useful in areas such as self-screening for reduced physical function, self-assessment in digital physiotherapy, and as measurement in research projects.
引用
收藏
页数:7
相关论文
共 37 条
  • [1] 30 SECONDS CHAIR STAND TEST - FEASIBLE AS SELF-ASSESSMENT TEST FOR KNEE OSTEOARTHRITIS?
    Ho-Henriksson, C. M.
    Thorstensson, C. A.
    Nordeman, L.
    ANNALS OF THE RHEUMATIC DISEASES, 2023, 82 : 2128 - 2128
  • [2] Pain pressure threshold algometry in knee osteoarthritis: intra- and inter-rater reliability
    Stausholm, Martin Bjorn
    Bjordal, Jan Magnus
    Moe-Nilssen, Rolf
    Naterstad, Ingvill Fjell
    PHYSIOTHERAPY THEORY AND PRACTICE, 2023, 39 (03) : 615 - 622
  • [3] Intra- and inter-rater reproducibility of the 6-minute walk test and the 30-second sit-to-stand test in patients with severe and very severe COPD
    Hansen, Henrik
    Beyer, Nina
    Frolich, Anne
    Godtfredsen, Nina
    Bieler, Theresa
    INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2018, 13 : 3447 - 3457
  • [4] KNEE OSTEOARTHRITIS, SARCOPENIA AND OVERWEIGHT: ARE THEY ASSOCIATED WITH THE 30-SECOND CHAIR STAND TEST?
    Venturini, P. J.
    Aily, J. B.
    Casonato, N. A.
    Mattiello, S. M.
    OSTEOARTHRITIS AND CARTILAGE, 2023, 31 : S185 - S186
  • [5] Intra- and inter-rater reliability of the Sollerman hand function test in patients with chronic stroke
    Brogardh, Christina
    Persson, Ann L.
    Sjolund, Bengt H.
    DISABILITY AND REHABILITATION, 2007, 29 (02) : 145 - 154
  • [6] Test-retest, intra- and inter-rater reliability of the reactive balance test in patients with chronic ankle instability
    Maricot, Alexandre
    Lathouwers, Elke
    Verschueren, Jo
    De Pauw, Kevin
    Meeusen, Romain
    Roelands, Bart
    Tassignon, Bruno
    FRONTIERS IN NEUROLOGY, 2024, 15
  • [7] Intra- and Inter-rater Reliability of the Lumbar-Locked Thoracic Rotation Test in Patients With Neck Pain
    Yoshida, Ryota
    Kuruma, Hironobu
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (03)
  • [8] Measuring the Pain Area: An Intra- and Inter-Rater Reliability Study Using Image Analysis Software
    Jandre dos Reis, Felipe Jose
    de Barros e Silva, Veronica
    de Lucena, Raphaela Nunes
    Mendes Cardoso, Bruno Alexandre
    Nogueira, Leandro Calazans
    PAIN PRACTICE, 2016, 16 (01) : 24 - 30
  • [9] Intra- and inter-rater reliability of the Knee Society Knee Score when used by two physiotherapists in patients post total knee arthroplasty
    Gopal, S.
    Wood, W.
    Myezwa, H.
    Stewart, A.
    SOUTH AFRICAN JOURNAL OF PHYSIOTHERAPY, 2010, 66 (01) : 21 - 25
  • [10] Ultrasound imaging in patients with hip pain and suspected hip osteoarthritis: an inter-rater and intra-rater reliability study
    Clausen, Stine
    Kjaer, Soren
    Fredberg, Ulrich
    Terslev, Lene
    Hartvigsen, Jan
    Arnbak, Bodil
    BMJ OPEN, 2020, 10 (11):