Monte Carlo Simulation of an Ir-192 Brachytherapy Source Spectra, Geometry and Anysotropy Factors Using Geant4 Code

被引:1
|
作者
Fonseca-Rodrigues, S. S. O. [1 ]
Begalli, M. [2 ]
Queiroz Filho, P. P. [1 ]
Souza-Santos, D. [1 ]
机构
[1] Inst Radioprotecao & Dosimetria, Av Salvador Allende S-N, BR-22780160 Rio De Janeiro, Brazil
[2] Univ Estado Rio De Janeiro, Inst Fis, Rio De Janeiro, Brazil
关键词
brachyterapy; Geant4; calculation of dose; DOSIMETRY; MODELS;
D O I
10.1109/NSSMIC.2009.5401657
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In brachytherapy cancer treatments, methods for Calculation of dose delivered to tumours and organs have been continuously improving. Monte Carlo methods are an important tool in dose calculation for brachytherapy cancer treatments, where the exposition to the source planning aims at the maximization of dose deposition in the target volume, while minimizing the deposition in healthy tissues. The use of interstitial brachytherapy sources follows the recommendations of AAPM REPORT No. 51. The present work is based on Monte Carlo simulations with the GEANT4 toolkit of the dose quantities recommended by that report. An Iridium-192 Buchler HDR source was simulated and the geometry of dose deposition in media and energy spectra have been obtained. Calculations also include the Dose Rate Constant Lambda, the Geometry Factor G(r,theta), the Anisotropy Function F(r,theta) and the Radial Dose Function g(r,theta).
引用
收藏
页码:544 / +
页数:2
相关论文
共 50 条
  • [31] The application of GEANT4 simulation code to the verification of a brachytherapy calibration procedure
    Foppiano, F
    Garelli, S
    Moresco, P
    Paoli, G
    Agostinelli, S
    USE OF COMPUTERS IN RADIATION THERAPY, 2000, : 500 - 501
  • [32] Dosimetry of indigenously developed Ir-192 high-dose rate brachytherapy source: An EGSnrc Monte Carlo study
    Sahoo, Sridhar
    Selvam, T. Palani
    Sharma, S. D.
    Das, Trupti
    Dey, A. C.
    Patil, B. N.
    Sastri, K. V. S.
    JOURNAL OF MEDICAL PHYSICS, 2016, 41 (02) : 115 - 122
  • [33] Design Optimization of a HDR Ir-192 Brachytherapy Skin Applicator Using Monte Carlo-Based Dosimetry
    Yang, Y.
    Rivard, M. J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3612 - 3612
  • [34] Healthy Tissue Dose Modeling Using Monte Carlo Methods for HDR Ir-192 Breast Brachytherapy Applicators
    Yang, Y.
    Zhang, Y.
    Rivard, M.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [35] Monte Carlo dosimetric study of best industries and alpha omega Ir-192 brachytherapy seeds
    Ballester, F
    Granero, D
    Pérez-Calatayud, J
    Casal, E
    Puchades, V
    MEDICAL PHYSICS, 2004, 31 (12) : 3298 - 3305
  • [36] The dose distribution close to an Ir-192 wire source: EGS4 Monte Carlo calculations
    Cheung, YC
    Yu, PKN
    Young, ECM
    Chan, CL
    Ng, MF
    Tang, F
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (02): : 401 - 406
  • [37] Investigation of TG-43 Dosimetric Parameters for 192Ir Brachytherapy Source Using GATE Monte Carlo Code
    Joya, Musa
    Nedaie, Hassan Ali
    Geraily, Ghazale
    Rezaei, Hadi
    Bromand, Awaz
    Ghorbani, Mahdi
    Sheikhzadeh, Peyman
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (03) : 268 - 273
  • [38] Monte Carlo Simulation of the Response to Fast Neutrons of a Multi-gap RPC (MRPC) by Using the GEANT4 Code
    Rhee, J. T.
    Jo, Hyun Yong
    Jamil, M.
    Jeon, Y. J.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (07) : 1023 - 1027
  • [39] Dosimetry characterization of 32P intravascular brachytherapy source wires using Monte Carlo codes PENELOPE and GEANT4
    Torres, J
    Buades, MJ
    Almansa, JF
    Guerrero, R
    Lallena, AM
    MEDICAL PHYSICS, 2004, 31 (02) : 296 - 304
  • [40] Absorbed dose estimations of 131I for critical organs using the GEANT4 Monte Carlo simulation code
    Rahman, Ziaur
    Rehman, Shakeel Ur
    Arshed, Waheed
    Mirza, Nasir M.
    Rashid, Abdul
    Zeb, Jahan
    CHINESE PHYSICS C, 2012, 36 (11) : 1150 - 1156