Absorbed dose estimations of 131I for critical organs using the GEANT4 Monte Carlo simulation code

被引:3
|
作者
Rahman, Ziaur [1 ]
Rehman, Shakeel Ur [2 ]
Arshed, Waheed [1 ]
Mirza, Nasir M. [2 ]
Rashid, Abdul [1 ]
Zeb, Jahan [1 ]
机构
[1] Pakistan Inst Nucl Sci & Technol, Div Hlth Phys, Islamabad 45650, Pakistan
[2] Pakistan Inst Engn & Appl Sci, Dept Phys & Appl Math, Islamabad 45650, Pakistan
关键词
mean absorbed dose rate; GEANT4; Monte Carlo simulation and I-131 critical organs;
D O I
10.1088/1674-1137/36/11/021
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The aim of this study is to compare the absorbed doses of critical organs of I-131 using the MIRD (Medical Internal Radiation Dose) with the corresponding predictions made by GEANT4 simulations. S-values (mean absorbed dose rate per unit activity) and energy deposition per decay for critical organs of I-131 for various ages, using standard cylindrical phantom comprising water and ICRP soft-tissue material, have also been estimated. In this study the effect of volume reduction of thyroid, during radiation therapy, on the calculation of absorbed dose is also being estimated using GEANT4. Photon specific energy deposition in the other organs of the neck, due to 1311 decay in the thyroid organ, has also been estimated. The maximum relative difference of MIRD with the GEANT4 simulated results is 5.64% for an adult's critical organs of I-131 Excellent agreement was found between the results of water and ICRP soft tissue using the cylindrical model. S-values are tabulated for critical organs of 1311, using 1, 5, 10, 15 and 18 years (adults) individuals. S-values for a cylindrical thyroid of different sizes, having 3.07% relative differences of GEANT4 with Siegel Si Stabin results. Comparison of the experimentally measured values at 0.5 and 1 m away from neck of the ionization chamber with GEANT4 based Monte Carlo simulations results show good agreement. This study shows that GEANT4 code is an important tool for the internal dosimetry calculations.
引用
收藏
页码:1150 / 1156
页数:7
相关论文
共 50 条
  • [1] Absorbed dose estimations of 131I for critical organs using the GEANT4 Monte Carlo simulation code
    Ziaur Rahman
    Shakeel ur Rehman
    Waheed Arshed
    Nasir M Mirza
    Abdul Rashid
    Jahan Zeb
    Chinese Physics C, 2012, (11) : 1150 - 1156
  • [2] Influence of thyroid volume reduction on absorbed dose in 131I therapy studied by using Geant4 Monte Carlo simulation
    Rahman, Ziaur
    Mirza, Sikander M.
    Arshed, Waheed
    Mirza, Nasir M.
    Ahmed, Waheed
    CHINESE PHYSICS C, 2014, 38 (05)
  • [3] Influence of thyroid volume reduction on absorbed dose in 131I therapy studied by using Geant4 Monte Carlo simulation
    Ziaur Rahman
    Sikander M Mirza
    Waheed Arshed
    Nasir M Mirza
    Waheed Ahmed
    Chinese Physics C, 2014, 38 (05) : 64 - 70
  • [4] Radioiodine (131I) treatment for Graves' disease: Geant4 Monte Carlo simulation for patient personalized dose estimation
    Meftah, S.
    Kraiem, T.
    Elj, S.
    Ben-Ismail, A.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (01): : 213 - 221
  • [5] A GEANT4 Monte-Carlo simulation code for precision β spectroscopy
    Wauters, F.
    Kraev, I.
    Zakoucky, D.
    Beck, M.
    Golovko, V. V.
    Kozlov, V. Yu.
    Phalet, T.
    Tandecki, M.
    Traykov, E.
    Van Gorp, S.
    Severijns, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 609 (2-3): : 156 - 164
  • [6] SIMULATION OF THE NEUTRON SPECTRA EVOLUTION WITH GEANT4 MONTE CARLO CODE
    Smolyar, V. P.
    Mileva, A. O.
    Tarasov, V. O.
    Neboha, H. H.
    Rusov, V. D.
    JOURNAL OF PHYSICAL STUDIES, 2021, 25 (02):
  • [7] Calculation of absorbed dose factors for Re-186 in radiation synovectomy using Monte Carlo simulation with Geant4
    Lagares, L. C.
    Veloza, L. S.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 1842 - 1845
  • [8] Simulation of absorbed dose, in molecular therapy, by means of Monte Carlo method using free software GEANT4: GATE
    Echevarria Torres, Waldo Jose
    Manso Nobrega, Weiner
    Gonzalez Gonzalez, Joaquin
    Fragoso Negrin, Jose Alejandro
    MEDISUR-REVISTA DE CIENCIAS MEDICAS DE CIENFUEGOS, 2022, 20 (02): : 222 - 231
  • [9] Monte Carlo simulation of MOSFET dosimeter for electron backscatter using the GEANT4 code
    Chow, James C. L.
    Leung, Michael K. K.
    MEDICAL PHYSICS, 2008, 35 (06) : 2383 - 2390
  • [10] Monte Carlo improvement of dose uniformity in gamma irradiation processing using the GEANT4 code
    Kadri, O
    Gharbi, F
    Farah, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 239 (04): : 391 - 398