Absorbed dose estimations of 131I for critical organs using the GEANT4 Monte Carlo simulation code

被引:3
|
作者
Rahman, Ziaur [1 ]
Rehman, Shakeel Ur [2 ]
Arshed, Waheed [1 ]
Mirza, Nasir M. [2 ]
Rashid, Abdul [1 ]
Zeb, Jahan [1 ]
机构
[1] Pakistan Inst Nucl Sci & Technol, Div Hlth Phys, Islamabad 45650, Pakistan
[2] Pakistan Inst Engn & Appl Sci, Dept Phys & Appl Math, Islamabad 45650, Pakistan
关键词
mean absorbed dose rate; GEANT4; Monte Carlo simulation and I-131 critical organs;
D O I
10.1088/1674-1137/36/11/021
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The aim of this study is to compare the absorbed doses of critical organs of I-131 using the MIRD (Medical Internal Radiation Dose) with the corresponding predictions made by GEANT4 simulations. S-values (mean absorbed dose rate per unit activity) and energy deposition per decay for critical organs of I-131 for various ages, using standard cylindrical phantom comprising water and ICRP soft-tissue material, have also been estimated. In this study the effect of volume reduction of thyroid, during radiation therapy, on the calculation of absorbed dose is also being estimated using GEANT4. Photon specific energy deposition in the other organs of the neck, due to 1311 decay in the thyroid organ, has also been estimated. The maximum relative difference of MIRD with the GEANT4 simulated results is 5.64% for an adult's critical organs of I-131 Excellent agreement was found between the results of water and ICRP soft tissue using the cylindrical model. S-values are tabulated for critical organs of 1311, using 1, 5, 10, 15 and 18 years (adults) individuals. S-values for a cylindrical thyroid of different sizes, having 3.07% relative differences of GEANT4 with Siegel Si Stabin results. Comparison of the experimentally measured values at 0.5 and 1 m away from neck of the ionization chamber with GEANT4 based Monte Carlo simulations results show good agreement. This study shows that GEANT4 code is an important tool for the internal dosimetry calculations.
引用
收藏
页码:1150 / 1156
页数:7
相关论文
共 50 条
  • [21] Geant4 Monte Carlo simulation of absorbed dose and radiolysis yields enhancement from a gold nanoparticle under MeV proton irradiation
    Tran, H. N.
    Karamitros, M.
    Ivanchenko, V. N.
    Guatelli, S.
    McKinnon, S.
    Murakami, K.
    Sasaki, T.
    Okada, S.
    Bordage, M. C.
    Francis, Z.
    El Bitar, Z.
    Bernal, M. A.
    Shin, J. I.
    Lee, S. B.
    Barberet, Ph.
    Tran, T. T.
    Brown, J. M. C.
    Hao, T. V. Nhan
    Incerti, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2016, 373 : 126 - 139
  • [22] Dose conversion coefficients for ICRP110 voxel phantom in the Geant4 Monte Carlo code
    Martins, M. C.
    Cordeiro, T. P. V.
    Silva, A. X.
    Souza-Santos, D.
    Queiroz-Filho, P. P.
    Hunt, J. G.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 95 : 309 - 312
  • [23] Specific absorbed fractions of electrons and photons for Digimouse voxelized phantom using GATE/GEANT4 Monte-Carlo simulation
    Laazouzi, Khaoula
    Boukhal, Hamid
    Chakir, El Mahjoub
    Arectout, Assia
    Hadouachi, Maryam
    Belhaj, Omaima Essaad
    APPLIED RADIATION AND ISOTOPES, 2023, 193
  • [24] Monte Carlo simulation of the Zeiss INTRABEAM with cylinder applicator using the GEANT4 precise dose calculation in the IORT
    Clausen, S.
    Schneider, F.
    Jahnke, L.
    Fleckenstein, J.
    Hesser, J.
    Wenz, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 51 - 51
  • [25] Monte Carlo Simulation of the Response to Fast Neutrons of a Multi-gap RPC (MRPC) by Using the GEANT4 Code
    Rhee, J. T.
    Jo, Hyun Yong
    Jamil, M.
    Jeon, Y. J.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (07) : 1023 - 1027
  • [26] Ambient Dose Equivalent Per Therapeutic Dose for 250 Mev Proton Interactions in Tissues using GEANT4 Monte Carlo Code
    Chen, Y.
    Ahmad, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S704 - S705
  • [27] Studying the response of a plastic scintillator to gamma rays using the Geant4 Monte Carlo code
    Ghadiri, Rasoul
    Khorsandi, Jamshid
    APPLIED RADIATION AND ISOTOPES, 2015, 99 : 63 - 68
  • [28] Monte Carlo simulation of laser beams interaction with the human eye using Geant4
    Diogo Tendeiro
    Gonçalo Lopes
    Pedro Vieira
    José Paulo Santos
    BioMedical Engineering OnLine, 13
  • [29] Monte Carlo simulation of laser beams interaction with the human eye using Geant4
    Tendeiro, Diogo
    Lopes, Goncalo
    Vieira, Pedro
    Santos, Jose Paulo
    BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [30] The Design of a Novel Direction Modulated Brachytherapy (DMBT) Vaginal Cylinder Using GEANT4 Monte Carlo Simulation Code
    Meftahi, M.
    Song, W.
    MEDICAL PHYSICS, 2020, 47 (06) : E857 - E858