Monte Carlo Simulation of an Ir-192 Brachytherapy Source Spectra, Geometry and Anysotropy Factors Using Geant4 Code

被引:1
|
作者
Fonseca-Rodrigues, S. S. O. [1 ]
Begalli, M. [2 ]
Queiroz Filho, P. P. [1 ]
Souza-Santos, D. [1 ]
机构
[1] Inst Radioprotecao & Dosimetria, Av Salvador Allende S-N, BR-22780160 Rio De Janeiro, Brazil
[2] Univ Estado Rio De Janeiro, Inst Fis, Rio De Janeiro, Brazil
关键词
brachyterapy; Geant4; calculation of dose; DOSIMETRY; MODELS;
D O I
10.1109/NSSMIC.2009.5401657
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In brachytherapy cancer treatments, methods for Calculation of dose delivered to tumours and organs have been continuously improving. Monte Carlo methods are an important tool in dose calculation for brachytherapy cancer treatments, where the exposition to the source planning aims at the maximization of dose deposition in the target volume, while minimizing the deposition in healthy tissues. The use of interstitial brachytherapy sources follows the recommendations of AAPM REPORT No. 51. The present work is based on Monte Carlo simulations with the GEANT4 toolkit of the dose quantities recommended by that report. An Iridium-192 Buchler HDR source was simulated and the geometry of dose deposition in media and energy spectra have been obtained. Calculations also include the Dose Rate Constant Lambda, the Geometry Factor G(r,theta), the Anisotropy Function F(r,theta) and the Radial Dose Function g(r,theta).
引用
收藏
页码:544 / +
页数:2
相关论文
共 50 条
  • [41] Monte Carlo improvement of dose uniformity in gamma irradiation processing using the GEANT4 code
    Kadri, O
    Gharbi, F
    Farah, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 239 (04): : 391 - 398
  • [42] Studying the response of a plastic scintillator to gamma rays using the Geant4 Monte Carlo code
    Ghadiri, Rasoul
    Khorsandi, Jamshid
    APPLIED RADIATION AND ISOTOPES, 2015, 99 : 63 - 68
  • [43] Monte Carlo simulation of laser beams interaction with the human eye using Geant4
    Diogo Tendeiro
    Gonçalo Lopes
    Pedro Vieira
    José Paulo Santos
    BioMedical Engineering OnLine, 13
  • [44] Monte Carlo simulation of laser beams interaction with the human eye using Geant4
    Tendeiro, Diogo
    Lopes, Goncalo
    Vieira, Pedro
    Santos, Jose Paulo
    BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [45] Calculation of Dosimetry Parameters for 192Ir and 125I Brachytherapy Sources Using Geant4
    Fonseca-Rodrigues, Sane S. O.
    Martins, Maximiano C.
    Begalli, Marcia
    Queiroz Filho, Pedro P.
    de Souza-Santos, Denison
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 1190 - 1192
  • [46] Absorbed dose estimations of 131I for critical organs using the GEANT4 Monte Carlo simulation code
    Ziaur Rahman
    Shakeel ur Rehman
    Waheed Arshed
    Nasir M Mirza
    Abdul Rashid
    Jahan Zeb
    Chinese Physics C, 2012, (11) : 1150 - 1156
  • [47] Simulation of Cherenkov photons emitted in photomultiplier windows induced by Compton diffusion using the Monte Carlo code GEANT4
    Thiam, C.
    Bobin, C.
    Bouchard, J.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (7-8) : 1515 - 1518
  • [48] Dosimetric investigation of high dose rate Ir-192 source with Monte Carlo method
    Acun, H.
    Bozkurt, A.
    Kemikler, G.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2017, 15 (03): : 241 - 249
  • [49] Determination of Position Resolution for LYSO Scintillation Crystals Using Geant4 Monte Carlo Code
    Yahya, M. F. O.
    Kocak, F.
    ADVANCES IN HIGH ENERGY PHYSICS, 2021, 2021 (2021)
  • [50] Monte Carlo verification of dosimetry for an Ir-192 pulsed dose rate source (WIP)
    Koch, N
    Mourtada, F
    Lawyer, A
    Horton, J
    MEDICAL PHYSICS, 2003, 30 (06) : 1514 - 1514