Modeling of a 400 kV Transmission Line of Bangladesh Power System Network

被引:0
|
作者
Emrose, Md Tanvir [1 ]
Chowdhury, A. H. [1 ]
Hasan, S. M. Mehedi [1 ]
机构
[1] Bangladesh Univ Engn & Technol, Dept Elect & Elect Engn, Dhaka, Bangladesh
关键词
transmission line model; tower footing resistance; surge arrester; insulators; lightning stroke; back-flashover; TOWER MODEL;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a detailed model of 400 kV AC double circuit transmission line between Ashuganj and Bhulta substations of Bangladesh power system network. Frequency dependent model is for overhead transmission lines, constant parameter distributed line model for tower, variable tower footing resistance model, and IEEE standard model for surge arrester are used for the purpose. The complete model is tested and verified using actual data by employing lightning strike.
引用
收藏
页码:1134 / 1139
页数:6
相关论文
共 50 条
  • [21] Analysing a 400 kV power system for an expert system switching
    Cipcigan, L
    Smith, KS
    Hiley, J
    MELECON 2000: INFORMATION TECHNOLOGY AND ELECTROTECHNOLOGY FOR THE MEDITERRANEAN COUNTRIES, VOLS 1-3, PROCEEDINGS, 2000, : 999 - 1002
  • [22] Safety distance for live working on ±400 kV DC transmission line interconnecting Qinghai power grid with tibet power grid
    Ding, Yujian
    Sun, Hui
    Li, Jun
    Zhou, Jun
    Li, Qingfeng
    Bai, Wei
    Ma, Le
    Dianwang Jishu/Power System Technology, 2014, 38 (10): : 2894 - 2899
  • [23] Performance Evaluation of Power Transmission System in Bangladesh
    Satter, Md Dara Abdus
    Ahmed, Md Raju
    2017 4TH INTERNATIONAL CONFERENCE ON ADVANCES IN ELECTRICAL ENGINEERING (ICAEE), 2017, : 587 - 592
  • [24] The measurement and assessment of corona power losses on 400 kV transmission lines
    Loxton, AE
    Britten, AC
    2002 IEEE AFRICON, VOLS 1 AND 2: ELECTROTECHNOLOGICAL SERVICES FOR AFRICA, 2002, : 613 - 616
  • [25] Power transmission line modeling - A comparison
    Duque, CA
    Szczupak, J
    40TH MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS 1 AND 2, 1998, : 1302 - 1305
  • [26] Protection system considerations for 400 kV series compensated transmission lines of the Central Western Network in Venezuela
    Castro, Rogelio A.
    Pineda, Hector A.
    2006 IEEE/PES TRANSMISSION & DISTRIBUTION CONFERENCE & EXPOSITION: LATIN AMERICA, VOLS 1-3, 2006, : 833 - +
  • [27] RECORDINGS OF RADIO INTERFERENCE FROM A 400 kV POWER LINE.
    Flink, Bo
    Svensson, Lennart
    1974, 26 (02): : 14 - 21
  • [28] Line Surge Arrester Application for a 380 kV Power Transmission Line
    Font, Aytug
    Ilhan, Suat
    Ozdemir, Aydogan
    2016 IEEE INTERNATIONAL CONFERENCE ON HIGH VOLTAGE ENGINEERING AND APPLICATION (ICHVE), 2016,
  • [29] Implementation of Second Earthwire on L6 400 kV Transmission Line
    Federico, Padoan
    Haddad, Manu
    Albano, Maurizio
    Robson, Stephen
    Guo Dongsheng
    Land, Christopher
    Loftus, Neil
    2022 57TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC 2022): BIG DATA AND SMART GRIDS, 2022,
  • [30] Probabilistic failure analysis of 400 kV transmission tower-line system subjected to wind and ice hazards
    Mahmoudi, Amir
    Nasrollahzadeh, Kourosh
    Jafari, Mohammad Ali
    WIND AND STRUCTURES, 2021, 33 (03) : 251 - 264