Modeling of a 400 kV Transmission Line of Bangladesh Power System Network

被引:0
|
作者
Emrose, Md Tanvir [1 ]
Chowdhury, A. H. [1 ]
Hasan, S. M. Mehedi [1 ]
机构
[1] Bangladesh Univ Engn & Technol, Dept Elect & Elect Engn, Dhaka, Bangladesh
关键词
transmission line model; tower footing resistance; surge arrester; insulators; lightning stroke; back-flashover; TOWER MODEL;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a detailed model of 400 kV AC double circuit transmission line between Ashuganj and Bhulta substations of Bangladesh power system network. Frequency dependent model is for overhead transmission lines, constant parameter distributed line model for tower, variable tower footing resistance model, and IEEE standard model for surge arrester are used for the purpose. The complete model is tested and verified using actual data by employing lightning strike.
引用
收藏
页码:1134 / 1139
页数:6
相关论文
共 50 条
  • [41] 380 kv POWER TRANSMISSION LINE OVER THE BOSPHORUS.
    Fenz, Johann
    Siemens power engineering, 1984, 6 (04): : 208 - 212
  • [42] Distance Protection and Automatic Reclosing on 400 kV Transmission Line with Classic and Compact Towers
    Alibasic, Emir
    Stojkov, Marinko
    Nikolovski, Srete
    PROCEEDINGS OF 2017 INTERNATIONAL CONFERENCE ON SMART SYSTEMS AND TECHNOLOGIES (SST), 2017, : 91 - 97
  • [43] IMPACT OF SVC DEVICES ON DISTANCE PROTECTION SETTING ZONES IN 400 kV TRANSMISSION LINE
    Zellagui, Mohamed
    Chaghi, Abdelaziz
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES C-ELECTRICAL ENGINEERING AND COMPUTER SCIENCE, 2013, 75 (02): : 249 - 262
  • [44] Artificial Neural Network Technique for Transmission Line Protection on Nigerian Power System
    Uzubi, Uma
    Ekwue, Arthur
    Ejiogu, Emenike
    2017 IEEE PES POWERAFRICA CONFERENCE, 2017, : 52 - 58
  • [45] Entropy generation in concentric annuli of 400 kV gas-insulated transmission line
    Hashemi-Tilehnoee, M.
    Tashakor, S.
    Dogonchi, A. S.
    Seyyedi, Seyyed Masoud
    Khaleghi, M.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2020, 19
  • [46] Impact of SVC devices on distance protection setting zones in 400 kV transmission line
    Zellagui, Mohamed
    Chaghi, Abdelaziz
    UPB Scientific Bulletin, Series C: Electrical Engineering, 2013, 75 (02): : 249 - 262
  • [47] OPTIMIZING IN THE TRANSMISSION POWER IN A SYSTEM FOR REMOTE METER READING OVER THE POWER-LINE NETWORK
    DOSTERT, K
    NTZ ARCHIV, 1989, 11 (02): : 85 - 89
  • [48] Studies of line switching overvoltage on the 150 kV and 500 kV transmission network of UTE
    Aparicio, Sofia
    Pizzini, Andrea
    Martinez, Roberto
    Curbelo, Carlos
    2018 IEEE 9TH POWER, INSTRUMENTATION AND MEASUREMENT MEETING (EPIM), 2018,
  • [49] A Study on the Modeling of the 154 kV Power System and the Prevention of Reverse Transmission in the Incheon Airport Area
    Kim K.
    Kim I.
    Transactions of the Korean Institute of Electrical Engineers, 2023, 72 (11): : 1502 - 1506
  • [50] Investigation of power regimes of Southern Eectrical Networks of 110 kV in case of disconnecting of the high voltage electric transmission line of 400 kV of Moldavian condensed power plant (MCPP) - Vulcaneshty
    Postolaty, V. M.
    Bicova, E. V.
    PROBLEMELE ENERGETICII REGIONALE, 2009, (01): : 25 - 41