Modeling of a 400 kV Transmission Line of Bangladesh Power System Network

被引:0
|
作者
Emrose, Md Tanvir [1 ]
Chowdhury, A. H. [1 ]
Hasan, S. M. Mehedi [1 ]
机构
[1] Bangladesh Univ Engn & Technol, Dept Elect & Elect Engn, Dhaka, Bangladesh
关键词
transmission line model; tower footing resistance; surge arrester; insulators; lightning stroke; back-flashover; TOWER MODEL;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a detailed model of 400 kV AC double circuit transmission line between Ashuganj and Bhulta substations of Bangladesh power system network. Frequency dependent model is for overhead transmission lines, constant parameter distributed line model for tower, variable tower footing resistance model, and IEEE standard model for surge arrester are used for the purpose. The complete model is tested and verified using actual data by employing lightning strike.
引用
收藏
页码:1134 / 1139
页数:6
相关论文
共 50 条
  • [31] 400 kV, 400 mA POWER SUPPLY
    Munderville, M.
    Kempkes, M.
    2017 IEEE 21ST INTERNATIONAL CONFERENCE ON PULSED POWER (PPC), 2017,
  • [32] ON LINE MICROPROCESSOR BASED RELAYING SCHEME FOR EHV/UHV TRANSMISSION-LINE - AN EXISTING 400 KV LINE
    ISLAM, KK
    BOSE, SK
    SINGH, LP
    ELECTRIC MACHINES AND POWER SYSTEMS, 1987, 12 (4-5): : 313 - 324
  • [33] Power transmission system modeling
    Ebrahimi, M.
    Whalley, R.
    Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, Vol 1, Pts A-C, 2005, : 2107 - 2111
  • [34] Comparative studies of transient and steady state analysis for a typical 765kV/400kV EHV transmission system in Indian power system
    Thukaram, D.
    Khincha, H. P.
    Shyamala, P.
    2006 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONIC, DRIVES AND ENERGY SYSTEMS, VOLS 1 AND 2, 2006, : 996 - +
  • [35] Elasticity modeling for transmission network expansion planning in deregulated power system
    Yu, Qiuxia
    Guo, Jianbo
    Duan, Xianzhong
    2007 42ND INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2007, : 57 - 61
  • [36] TRANSMISSION AFTER 400-KV
    不详
    ELECTRICAL REVIEW, 1969, 184 (26): : 923 - &
  • [37] Vulnerability Analysis of Bangladesh Power System Network
    Al Hasnain, Fahim
    Chowdhury, Atique Mahmud A. H.
    2016 9TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (ICECE), 2016, : 393 - 395
  • [38] On research with transmission line modeling (TLM) to calculate and analyze power transmission line
    Li, FX
    ISTM/2003: 5TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-6, CONFERENCE PROCEEDINGS, 2003, : 1526 - 1530
  • [39] Failure causes and operational life of measuring transformers installed in 150 kV and 400 kV transmission network
    Barkas, D. A.
    Katemliadis, S.
    Tarousinof, G.
    Kalkanis, K.
    Psomopoulos, C. S.
    ELECTRIC POWER SYSTEMS RESEARCH, 2024, 231
  • [40] Experience with an on-line monitoring system for 400 kV XLPE cables
    Henningsen, CG
    Polster, K
    Fruth, BA
    Gross, DW
    1996 IEEE TRANSMISSION AND DISTRIBUTION CONFERENCE PROCEEDINGS, 1996, : 515 - 520