Implementation of Second Earthwire on L6 400 kV Transmission Line

被引:0
|
作者
Federico, Padoan [1 ]
Haddad, Manu [1 ]
Albano, Maurizio [1 ]
Robson, Stephen [1 ]
Guo Dongsheng [2 ]
Land, Christopher [2 ]
Loftus, Neil [2 ]
机构
[1] Cardiff Univ, Adv High Voltage Engn Res Ctr, Cardiff, Wales
[2] Natl Grid, London, England
关键词
Earthwire; OPGW; induced currents; datalogger systems;
D O I
10.1109/UPEC55022.2022.9917671
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The Earthwire is an important device to shield the transmission line from lightnings and to exchange information among the substations. OPGWs (Optical ground wires) are widely used for these purposes. Technical operations on the line impose a temporary implementation of a second earthwire between the two circuits. In this paper a study is undertook to understand the possible variations in the electric and magnetic field distribution and the induced currents due to the installation in a trial site of the second OPGW. In order to ensure reliabilty to the simulation, a comparison of three different calculation techniques has been conducted, and a boundary element Method has been then implemented in COMSOL Multiphysics to study a 3D configuration of the line and quantify the electric field around the pylons. To estimate the induced currents, the software ATP-EMTP has been used simulating the conditions with and without the second earthwire. Good agreement has been reached between the different numerical techniques for the field calculation, and a high value of induced current has been found on the ground wires in the case of the implementation of a second one. A measurement system has been built in Cardiff University to measure in June and August 2022 the induced current values and validate the numerical models.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] DEFINITION AND IMPLEMENTATION OF L6 IN BCL
    HOUSDEN, RJW
    COMPUTER JOURNAL, 1969, 12 (01): : 15 - &
  • [2] Performance of IPFC in a 400kV Transmission Line
    Charan, T. Vishnu
    Parimi, Alivelu M.
    2018 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENERGY SYSTEMS (ICEES), 2018, : 184 - 189
  • [3] Insulation design of 400 KV transmission line towers
    Chanana, Anil
    Irrigation and Power, 1988, 45 (04): : 25 - 35
  • [4] 400 kV TRANSMISSION LINE AND TRANSFORMER STATION IN HUNGARY.
    Haidegger, G.
    Hungarian Heavy Industries, 1973, 23 : 17 - 26
  • [5] About the flashover risk of a 400 kV transmission line insulation
    Nicoara, B.
    Revue roumaine de sciences techniques. Serie electrotechnique et energetique, 1988, 33 (04): : 351 - 357
  • [6] Modeling of a 400 kV Transmission Line of Bangladesh Power System Network
    Emrose, Md Tanvir
    Chowdhury, A. H.
    Hasan, S. M. Mehedi
    2020 IEEE REGION 10 SYMPOSIUM (TENSYMP) - TECHNOLOGY FOR IMPACTFUL SUSTAINABLE DEVELOPMENT, 2020, : 1134 - 1139
  • [7] ACETYLCHOLINE-RECEPTOR OF A MYOGENIC CELL LINE, L6
    SETO, A
    ARIMATSU, Y
    AMANO, T
    JOURNAL OF BIOCHEMISTRY, 1977, 82 (04): : 1019 - 1024
  • [8] Analysis of Transient Recovery Voltage in 400 kV SF6 Circuit Breaker Due to Transmission Line Faults
    Filipovic-Grcic, Bozidar
    Uglesic, Ivo
    Filipovic-Grcic, Dalibor
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2011, 6 (05): : 2652 - 2658
  • [9] ON LINE MICROPROCESSOR BASED RELAYING SCHEME FOR EHV/UHV TRANSMISSION-LINE - AN EXISTING 400 KV LINE
    ISLAM, KK
    BOSE, SK
    SINGH, LP
    ELECTRIC MACHINES AND POWER SYSTEMS, 1987, 12 (4-5): : 313 - 324
  • [10] INFLUENCE OF EXTERNAL DIFFUSIBLE FACTORS ON MYOGENESIS OF THE CELLS OF THE LINE L6
    DELAIN, D
    WAHRMANN, JP
    GROS, F