Novel scintillation detector design and performance for proton radiography and computed tomography

被引:63
|
作者
Bashkirov, V. A. [1 ]
Schulte, R. W. [1 ]
Hurley, R. F. [1 ]
Johnson, R. P. [2 ]
Sadrozinski, H. F. -W. [2 ]
Zatserklyaniy, A. [2 ]
Plautz, T. [2 ]
Giacometti, V. [3 ]
机构
[1] Loma Linda Univ, Dept Basic Sci, 11175 Campus St, Loma Linda, CA 92354 USA
[2] Univ Calif Santa Cruz, Dept Phys, 1156 High St, Santa Cruz, CA 95064 USA
[3] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
proton computed tomography; proton radiography; proton therapy; WEPL; proton energy detector; proton range measurement;
D O I
10.1118/1.4939255
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Proton computed tomography (pCT) will enable accurate prediction of proton and ion range in a patient while providing the benefit of lower radiation exposure than in x-ray CT. The accuracy of the range prediction is essential for treatment planning in proton or ion therapy and depends upon the detector used to evaluate the water-equivalent path length (WEPL) of a proton passing through the object. A novel approach is presented for an inexpensive WEPL detector for pCT and proton radiography. Methods: A novel multistage detector with an aperture of 10 x 37.5 cm was designed to optimize the accuracy of the WEPL measurements while simplifying detector construction and the performance requirements of its components. The design of the five-stage detector was optimized through simulations based on the GEANT4 detector simulation toolkit, and the fabricated prototype was calibrated in water-equivalent millimeters with 200 MeV protons in the research beam line of the clinical proton synchrotron at Loma Linda University Medical Center. A special polystyrene step phantom was designed and built to speed up and simplify the calibration procedure. The calibrated five-stage detector was tested in the 200 MeV proton beam as part of the pCT head scanner, using a water phantom and polystyrene slabs to verify the WEPL reconstruction accuracy. Results: The beam-test results demonstrated excellent performance of the new detector, in good agreement with the simulation results. The WEPL measurement accuracy is about 3 0 mm per proton in the 0-260 mm WEPL range required for a pCT head scan with a 200 MeV proton beam. Conclusions: The new multistage design approach to WEPL measurements for proton CT and radiography has been prototyped and tested. The test results show that the design is competitive with much more expensive calorimeter and range-counter designs. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:664 / 674
页数:11
相关论文
共 50 条
  • [11] An experimental demonstration of a new type of proton computed tomography using a novel silicon tracking detector
    Taylor, J. T.
    Poludniowski, G.
    Price, T.
    Waltham, C.
    Allport, P. P.
    Casse, G. L.
    Esposito, M.
    Evans, P. M.
    Green, S.
    Manger, S.
    Manolopoulos, S.
    Nieto-Camero, J.
    Parker, D. J.
    Symons, J.
    Allinson, N. M.
    MEDICAL PHYSICS, 2016, 43 (11) : 6129 - 6136
  • [12] A Proton Radiography System Design Using a Liquid Scintillator Detector
    Darne, C. D.
    Robertson, D. G.
    Alsanea, F.
    Guan, F.
    Pan, T.
    Grosshans, D. R.
    Gautam, A. S.
    Beddar, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2019, 105 (01): : E716 - E717
  • [13] Comparison of computed radiography and multi-detector computed tomography in the detection of postmortem metacarpal index
    Reid, Aoife
    Schneider-Kolsky, Michal Elisabeth
    O'Donnell, Christopher James
    FORENSIC SCIENCE INTERNATIONAL, 2008, 177 (2-3) : 192 - 198
  • [14] A Novel Integrating Proton Radiography System with a Monolithic Scintillator Detector
    Darne, C.
    Robertson, D.
    Alsanea, F.
    Tendler, I.
    Perles, L.
    Collins-Fekete, C.
    Beddar, S.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [15] Slot scintillation detector modeling for digital radiography
    Alcón, EPQ
    Lopes, RT
    RADIATION PHYSICS AND CHEMISTRY, 2001, 61 (3-6) : 411 - 414
  • [16] A novel proton-integrating radiography system design using a monolithic scintillator detector: Experimental studies
    Darne, Chinmay D.
    Robertson, Daniel G.
    Alsanea, Fahed
    Collins-Fekete, Charles-Antoine
    Beddar, Sam
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1027
  • [17] Characterization of a Silicon Strip Detector and a YAG:Ce Calorimeter for a Proton Computed Radiography Apparatus
    Menichelli, David
    Bruzzi, Mara
    Bucciolini, Marta
    Candiano, Giuliana
    Cirrone, Giuseppe A. Pablo
    Capineri, Lorenzo
    Civinini, Carlo
    Cuttone, Giacomo
    Lo Presti, Domenico
    Marrazzo, Livia
    Pallotta, Stefania
    Randazzo, Nunzio
    Sipala, Valeria
    Talamonti, Cinzia
    Valentini, Samuela
    Pieri, Stefano
    Reggioli, Valentina
    Brianzi, Mirko
    Tesi, Mauro
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 8 - 16
  • [18] A novel system and approach for proton radiography using a monolithic scintillator detector
    Darne, C.
    Robertson, D.
    Collins-Fekete, C.
    Beddar, S.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1373 - S1375
  • [19] Comparing the diagnostic performance of radiation dose-equivalent radiography, multi-detector computed tomography and cone beam computed tomography for finger fractures - A phantom study
    Reidelbach, Carolin Sophie
    Goerke, Sebastian Moritz
    Leschka, Simon Carl
    Neubauer, Claudia
    Soschynski, Martin
    Lampert, Florian
    Zajonc, Horst
    Kotter, Elmar
    Langer, Mathias
    Neubauer, Jakob
    PLOS ONE, 2019, 14 (03):
  • [20] History of proton radiography and tomography
    Hanson, Kenneth
    Schneider, Uwe
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2022, 32 (01): : 2 - 4