Ring Artifacts Reduction in Cone-Beam CT Images based on Independent Component Analysis

被引:0
|
作者
Chen, Yen-Wei [1 ,2 ]
Duan, Guifang [2 ]
Fujita, Akinori [3 ]
Hirooka, Ken [3 ]
Ueno, Yoshihiro [3 ]
机构
[1] Cent South Univ Forest & Tech, Elect & Inf Eng Sch, Changsha, Hunan, Peoples R China
[2] Ritsumeikan Univ, Grad Sch Sci & Engn, Kyoto, Japan
[3] Shimadzu Co Ltd, Technol Res Lab, Kyoto, Japan
关键词
CBCT image; Ring artifact reduction; Mean filter; Independent component analysis (ICA); MICROTOMOGRAPHY; TOMOGRAPHY;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Cone-beam CT (CBCT) scanners are based on volumetric tomography, using a 2D extended digital array providing an area detector [1]. Compared to traditional CT, CBCT has many advantages, such as less X-ray beam limitation, high image accuracy, rapid scan time, etc. However, In CBCT images there are always some ring artifacts that appear as rings centered on the rotation axis. Due to the data of the constructed images are corrupted by these ring artifacts, qualitative and quantitative analysis of CBCT images will be compromised. Post processing and application such as image segmentation and registration also turn more complex as the presence of such artifacts. In this paper, a method based on independent component analysis (ICA) is presented. It deals with the reconstructed CBCT image and can effectively reduce such ring artifacts.
引用
收藏
页码:1687 / +
页数:3
相关论文
共 50 条
  • [41] Root canal sealers affect artifacts on cone-beam computed tomography images
    Hazuki Miyashita
    Rieko Asaumi
    Ayaka Sakamoto
    Taisuke Kawai
    Masaru Igarashi
    Odontology, 2021, 109 : 679 - 686
  • [42] A novel noise suppression solution in cone-beam CT images
    Fan, Yi
    Lu, Hongbing
    Zhu, Hongbin
    Wang, Jing
    Lin, Qin
    Liang, Zhengrong
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [43] Detection of Collaterals from Cone-Beam CT Images in Stroke
    Abd Aziz, Azrina
    Izhar, Lila Iznita
    Asirvadam, Vijanth Sagayan
    Tang, Tong Boon
    Ajam, Azimah
    Omar, Zaid
    Muda, Sobri
    SENSORS, 2021, 21 (23)
  • [44] Motion Estimation Using Cone-Beam CT Projection Images
    Becker, N.
    Kay, I.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [45] A half-scan error reduction based algorithm for cone-beam CT
    Zeng, Kai
    Chen, Zhiqiang
    Zhang, Li
    Wang, Ge
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2004, 12 (02) : 73 - 82
  • [46] Model-based registration for pneumothorax deformation analysis using intraoperative cone-beam CT images
    Maekawa, Hinako
    Nakao, Megumi
    Mineura, Katsutaka
    Chen-Yoshikawa, Toyofumi F.
    Matsuda, Tetsuya
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 5818 - 5821
  • [47] Segmentation of Anterior Tissues in Craniofacial Cone-Beam CT Images
    Misra, Dharitri
    Gill, Michael
    Lee, Janice S.
    Antani, Sameer
    2020 IEEE 33RD INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS(CBMS 2020), 2020, : 71 - 76
  • [48] Reduction of cone-beam CT artifacts in a robotic CBCT device using saddle trajectories with integrated infrared tracking
    Wei, Chengtao
    Albrecht, Johanna
    Rit, Simon
    Laurendeau, Matthieu
    Thummerer, Adrian
    Corradini, Stefanie
    Belka, Claus
    Steininger, Philipp
    Ginzinger, Felix
    Kurz, Christopher
    Riboldi, Marco
    Landry, Guillaume
    MEDICAL PHYSICS, 2024, 51 (03) : 1674 - 1686
  • [49] Tri-Domain Peristaltic Artifact Reduction Model for Mitigating Motion Artifacts in Cone-Beam CT Imaging
    Onishi, T.
    Nakamura, M.
    Nakao, M.
    Mizowaki, T.
    MEDICAL PHYSICS, 2024, 51 (09) : 6552 - 6552
  • [50] The effect of MV cone-beam CT cupping artifacts on dose calculation accuracy
    Chen, J
    Morin, O
    Chen, H
    Aubin, M
    Pouliot, J
    MEDICAL PHYSICS, 2005, 32 (06) : 1936 - 1936