Ring Artifacts Reduction in Cone-Beam CT Images based on Independent Component Analysis

被引:0
|
作者
Chen, Yen-Wei [1 ,2 ]
Duan, Guifang [2 ]
Fujita, Akinori [3 ]
Hirooka, Ken [3 ]
Ueno, Yoshihiro [3 ]
机构
[1] Cent South Univ Forest & Tech, Elect & Inf Eng Sch, Changsha, Hunan, Peoples R China
[2] Ritsumeikan Univ, Grad Sch Sci & Engn, Kyoto, Japan
[3] Shimadzu Co Ltd, Technol Res Lab, Kyoto, Japan
关键词
CBCT image; Ring artifact reduction; Mean filter; Independent component analysis (ICA); MICROTOMOGRAPHY; TOMOGRAPHY;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Cone-beam CT (CBCT) scanners are based on volumetric tomography, using a 2D extended digital array providing an area detector [1]. Compared to traditional CT, CBCT has many advantages, such as less X-ray beam limitation, high image accuracy, rapid scan time, etc. However, In CBCT images there are always some ring artifacts that appear as rings centered on the rotation axis. Due to the data of the constructed images are corrupted by these ring artifacts, qualitative and quantitative analysis of CBCT images will be compromised. Post processing and application such as image segmentation and registration also turn more complex as the presence of such artifacts. In this paper, a method based on independent component analysis (ICA) is presented. It deals with the reconstructed CBCT image and can effectively reduce such ring artifacts.
引用
收藏
页码:1687 / +
页数:3
相关论文
共 50 条
  • [31] Phantom development for artifact reduction in cone-beam CT
    Keely, A.
    Kyprianou, I.
    Jennings, R.
    Myers, K.
    Gilat-Schmidt, T.
    MEDICAL PHYSICS, 2007, 34 (06) : 2340 - 2340
  • [32] Cone-Beam Computed Tomography (CBCT) to Computed Tomography (CT) Image Translation with Perceptual Loss to Eliminate Cone-Beam Artifacts
    Yoo, S.
    Choi, B.
    Park, I.
    Kim, J.
    Kim, H.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [33] Analysis of Cone-Beam Artifacts in off-Centered Circular CT for Four Reconstruction Methods
    Valton, S.
    Peyrin, F.
    Sappey-Marinier, D.
    INTERNATIONAL JOURNAL OF BIOMEDICAL IMAGING, 2006, 2006
  • [34] Metal Artifact Reduction based on 2D-Projection Correction for Dental Cone-beam CT Images
    Narkbuakaew, Walita
    Aootaphao, Sorapong
    Thanasupsombat, Chalinee
    Thongvigitmanee, Saowapak S.
    13TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2021), 2018,
  • [35] Cone-Beam Angle Dependency of 3D Models Computed from Cone-Beam CT Images
    Cho, Myung Hye
    Hegazy, Mohamed A. A.
    Cho, Min Hyoung
    Lee, Soo Yeol
    SENSORS, 2022, 22 (03)
  • [36] Removing ring artifacts in cone-beam CT via TV-Stokes and unidirectional total variation model
    Wu, Huantang
    Li, Jianwu
    Wang, Hong
    MEDICAL PHYSICS, 2019, 46 (04) : 1719 - 1727
  • [37] Root canal sealers affect artifacts on cone-beam computed tomography images
    Miyashita, Hazuki
    Asaumi, Rieko
    Sakamoto, Ayaka
    Kawai, Taisuke
    Igarashi, Masaru
    ODONTOLOGY, 2021, 109 (03) : 679 - 686
  • [38] Reducing Artifacts in Cone-Beam CT Images Caused by the Presence of An Array Used for Tracking Transponders during Radiotherapy
    Maurer, J.
    Godfrey, D.
    Wu, Q.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [39] Known-component metal artifact reduction (KC-MAR) for cone-beam CT
    Uneri, A.
    Zhang, X.
    Yi, T.
    Stayman, J. W.
    Helm, P. A.
    Osgood, G. M.
    Theodore, N.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (16):
  • [40] Evaluation of artifacts generated by zirconium implants in cone-beam computed tomography images
    Vasconcelos, Taruska Ventorini
    Bechara, Boulos B.
    McMahan, Clyde Alex
    Freitas, Deborah Queiroz
    Noujeim, Marcel
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2017, 123 (02): : 265 - 272