Ring Artifacts Reduction in Cone-Beam CT Images based on Independent Component Analysis

被引:0
|
作者
Chen, Yen-Wei [1 ,2 ]
Duan, Guifang [2 ]
Fujita, Akinori [3 ]
Hirooka, Ken [3 ]
Ueno, Yoshihiro [3 ]
机构
[1] Cent South Univ Forest & Tech, Elect & Inf Eng Sch, Changsha, Hunan, Peoples R China
[2] Ritsumeikan Univ, Grad Sch Sci & Engn, Kyoto, Japan
[3] Shimadzu Co Ltd, Technol Res Lab, Kyoto, Japan
关键词
CBCT image; Ring artifact reduction; Mean filter; Independent component analysis (ICA); MICROTOMOGRAPHY; TOMOGRAPHY;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Cone-beam CT (CBCT) scanners are based on volumetric tomography, using a 2D extended digital array providing an area detector [1]. Compared to traditional CT, CBCT has many advantages, such as less X-ray beam limitation, high image accuracy, rapid scan time, etc. However, In CBCT images there are always some ring artifacts that appear as rings centered on the rotation axis. Due to the data of the constructed images are corrupted by these ring artifacts, qualitative and quantitative analysis of CBCT images will be compromised. Post processing and application such as image segmentation and registration also turn more complex as the presence of such artifacts. In this paper, a method based on independent component analysis (ICA) is presented. It deals with the reconstructed CBCT image and can effectively reduce such ring artifacts.
引用
收藏
页码:1687 / +
页数:3
相关论文
共 50 条
  • [21] Analysis of scatter artifacts in cone-beam CT due to scattered radiation of metallic objects
    Iuso, Domenico
    Frysch, Robert
    Pfeiffer, Tim
    Rose, Georg
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072
  • [22] Analysis of ring artifacts of CT images
    Pang, Y.-W.
    Wang, Z.-B.
    Lin, M.
    Yue, H.-X.
    Huabei Gongxueyuan Xuebao/Journal of North China Institute of Technology, 2001, 22 (01): : 16 - 19
  • [23] Noise Properties in Helical Cone-beam CT Images
    Xia, Dan
    Sidky, Emil Y.
    Yu, Lifeng
    Pan, Xiaochuan
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 3428 - 3430
  • [24] Convolutional Network Based Motion Artifact Reduction in Cone-Beam CT
    Paysan, P.
    Strzelecki, A.
    Arrate, F.
    Munro, P.
    Scheib, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E340 - E341
  • [25] Two methods for reducing moving metal artifacts in cone-beam CT
    Hahn, Andreas
    Knaup, Michael
    Brehm, Marcus
    Sauppe, Sebastian
    Kachelriess, Marc
    MEDICAL PHYSICS, 2018, 45 (08) : 3671 - 3680
  • [26] An energy minimization method for the correction of cupping artifacts in cone-beam CT
    Xie, Shipeng
    Zhuang, Wenqin
    Li, Haibo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 307 - 319
  • [27] Dependence of cone-beam CT artifacts on the frequency content of the imaged object
    Jaffray, D
    Clackdoyle, R
    Siewerdsen, J
    Noo, F
    MEDICAL PHYSICS, 2003, 30 (06) : 1407 - 1407
  • [28] A Novel Method for Characterizing Beam Hardening Artifacts in Cone-beam Computed Tomographic Images
    Fox, Aaron
    Basrani, Bettina
    Kishen, Anil
    Lam, Ernest W. N.
    JOURNAL OF ENDODONTICS, 2018, 44 (05) : 869 - 874
  • [29] Expression of beam hardening artifacts on horizontally stitched cone-beam computed tomography images
    da Fonte, Juliana B. Melo
    Fontenele, Rocharles Cavalcante
    Freitas, Deborah Queiroz
    IMAGING SCIENCE IN DENTISTRY, 2024,
  • [30] Reduction of ring artifacts in cone beam CT: Artifact detection and correction for flat panel imagers
    Altunbas, M.
    Shaw, C.
    Chen, L.
    MEDICAL PHYSICS, 2006, 33 (06) : 2287 - 2288