The effect of MV cone-beam CT cupping artifacts on dose calculation accuracy

被引:2
|
作者
Chen, J [1 ]
Morin, O [1 ]
Chen, H [1 ]
Aubin, M [1 ]
Pouliot, J [1 ]
机构
[1] Univ Calif San Francisco, Ctr Comprehens Canc, San Francisco, CA 94143 USA
关键词
D O I
10.1118/1.1997618
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: MV cone‐beam (CB) CT imaging can be used to position the patient prior to external‐beam radiotherapy. If calibrated, these images may also be used in dose calculations, opening the possibility to reconstruct the delivered dose or re‐optimize the treatment plan before delivery. This study investigates the effect of imaging artifacts on dosimetric accuracy. Method and Materials: Two water cylinders of 13 cm and 22.5 cm diameters were imaged using A) a MV CBCT system integrated with a Siemens accelerator and B) a conventional kV CT imager. Cupping trends observed in the MV CBCT were imposed on the kV CT images to create artificial data with simulated artifacts. Using the Phillips Pinnacle planning system, a 6 MV 10 × 16 cm2 field was applied to 1) the original kV CT of the smaller cylinder and 2) the kV CT with simulated artifacts. Similarly, a 18 × 18 cm2 field was applied to the original and artificial kV CT of the larger cylinder. Results: For the smaller cylinder, the MV CBCT water signal relative to air at the cylinder center differs from the radial and axial extremities by approximately 14% and 17% respectively. For the larger cylinder, the differences are 38% and 20% in radial and axial directions. The dose distributions for the artificial images show a systematic deviation which increases with depth. In the high‐dose, low‐gradient regions, the largest deviation for the smaller cylinder is 1% of the maximum delivered dose. For the larger cylinder, the largest deviation is 4%. Conclusion: Cupping artifacts in water phantoms produce dosimetric errors much smaller in magnitude than the cupping trend itself but as large as 4% for large phantoms. These results suggest that rough correction of MV CBCT artifacts may be sufficient for dosimetric accuracy. Conflict of Interest: Research supported by Siemens OCS. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1936 / 1936
页数:1
相关论文
共 50 条
  • [1] DOSE CALCULATION USING MV CONE-BEAM CT: CORRECTION OF CUPPING ARTIFACTS, MISSING DATA AND ED CALIBRATION
    Petit, S.
    van Elmpt, W.
    Lambin, P.
    Dekker, A.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S54 - S54
  • [2] Dose calculation on megavoltage cone-beam CT images corrected for cupping and missing data artifacts
    Aubry, J.
    Morin, O.
    Faddegon, B.
    Nunna, C.
    Beaulieu, L.
    Pouliot, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2342 - 2342
  • [3] Quantitative Evaluation of Metal Artifacts in CT and Cone-Beam CT Images On the Accuracy of Dose Calculation
    Oyewale, S.
    Ahmad, S.
    Ali, I.
    MEDICAL PHYSICS, 2012, 39 (06) : 3825 - 3825
  • [4] Various procedures for the reduction of cupping artifacts in MegaVoltage Cone-Beam CT
    Petit, S.
    van Elmpt, W.
    Nijsten, S.
    Dekker, A.
    Lambin, P.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S232 - S233
  • [5] An energy minimization method for the correction of cupping artifacts in cone-beam CT
    Xie, Shipeng
    Zhuang, Wenqin
    Li, Haibo
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 307 - 319
  • [6] Delivered dose reconstruction with MV cone-beam CT
    Pouliot, J
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S88 - S88
  • [7] Impact of cone-beam computed tomography artifacts on dose calculation accuracy for lung cancer
    Schroder, Lukas
    Bootsma, Gregory
    Stankovic, Uros
    Ploeger, Lennert
    Sonke, Jan-Jakob
    MEDICAL PHYSICS, 2024, 51 (07) : 4709 - 4720
  • [8] Effects of cone-beam CT noise and cupping artifacts on deformable image registration
    Murphy, M.
    Lu, L.
    Crimaldi, A.
    Cuttino, L.
    Shield, C.
    Keall, P.
    Siebers, J.
    Williamson, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 1996 - 1996
  • [9] Cupping artifacts analysis and correction for a FPD-based cone-beam CT
    Zhang Li
    Gao Hewei
    Li Shuanglei
    Chen Zhiqiang
    Xing Yuxiang
    COMPUTATIONAL IMAGING IV, 2006, 6065
  • [10] A study of accuracy evaluation of dose distribution calculation based on the cone-beam CT
    Fujimoto, K.
    Tateoka, K.
    Hareyama, M.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S839 - S839