The effect of MV cone-beam CT cupping artifacts on dose calculation accuracy

被引:2
|
作者
Chen, J [1 ]
Morin, O [1 ]
Chen, H [1 ]
Aubin, M [1 ]
Pouliot, J [1 ]
机构
[1] Univ Calif San Francisco, Ctr Comprehens Canc, San Francisco, CA 94143 USA
关键词
D O I
10.1118/1.1997618
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: MV cone‐beam (CB) CT imaging can be used to position the patient prior to external‐beam radiotherapy. If calibrated, these images may also be used in dose calculations, opening the possibility to reconstruct the delivered dose or re‐optimize the treatment plan before delivery. This study investigates the effect of imaging artifacts on dosimetric accuracy. Method and Materials: Two water cylinders of 13 cm and 22.5 cm diameters were imaged using A) a MV CBCT system integrated with a Siemens accelerator and B) a conventional kV CT imager. Cupping trends observed in the MV CBCT were imposed on the kV CT images to create artificial data with simulated artifacts. Using the Phillips Pinnacle planning system, a 6 MV 10 × 16 cm2 field was applied to 1) the original kV CT of the smaller cylinder and 2) the kV CT with simulated artifacts. Similarly, a 18 × 18 cm2 field was applied to the original and artificial kV CT of the larger cylinder. Results: For the smaller cylinder, the MV CBCT water signal relative to air at the cylinder center differs from the radial and axial extremities by approximately 14% and 17% respectively. For the larger cylinder, the differences are 38% and 20% in radial and axial directions. The dose distributions for the artificial images show a systematic deviation which increases with depth. In the high‐dose, low‐gradient regions, the largest deviation for the smaller cylinder is 1% of the maximum delivered dose. For the larger cylinder, the largest deviation is 4%. Conclusion: Cupping artifacts in water phantoms produce dosimetric errors much smaller in magnitude than the cupping trend itself but as large as 4% for large phantoms. These results suggest that rough correction of MV CBCT artifacts may be sufficient for dosimetric accuracy. Conflict of Interest: Research supported by Siemens OCS. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1936 / 1936
页数:1
相关论文
共 50 条
  • [41] Initial Investigation of Dose Calculation On Intra-Irradiation Cone-Beam CT Images
    Iramina, H.
    Nakamura, M.
    Mizowaki, T.
    MEDICAL PHYSICS, 2020, 47 (06) : E629 - E630
  • [42] Dose calculation on cone beam CT (CBCT)
    Chi, Y.
    Wu, Q.
    Yan, D.
    MEDICAL PHYSICS, 2007, 34 (06) : 2438 - 2438
  • [43] Compensators for management of dose and scatter in cone-beam CT
    Graham, S.
    Moseley, D.
    Siewerdsen, J.
    Jaffray, D.
    MEDICAL PHYSICS, 2006, 33 (06) : 1998 - 1999
  • [44] Dose Measurement Methodology for Dental Cone-Beam CT
    Deman, P.
    Atwal, P.
    Duzenli, C.
    Thakur, Y.
    Ford, N.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [45] Small animal photon counting cone-beam CT on a preclinical radiation research platform to improve radiation dose calculation accuracy
    Hu, Xiaoyu
    Zhong, Yuncheng
    Lai, Youfang
    Shen, Chenyang
    Yang, Kai
    Jia, Xun
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (19):
  • [46] Dose calculation accuracy of different image value to density tables for cone-beam CT planning in head & neck and pelvic localizations
    Barateau, Anais
    Garlopeau, Christopher
    Cugny, Audrey
    De Figueiredo, Benedicte Henriques
    Dupin, Charles
    Caron, Jerome
    Antoine, Mikael
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (02): : 146 - 151
  • [47] Improving dose calculation accuracy in preclinical radiation experiments using multi-energy element resolved cone-beam CT
    Huang, Yanqi
    Hu, Xiaoyu
    Zhong, Yuncheng
    Lai, Youfang
    Shen, Chenyang
    Jia, Xun
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (24):
  • [48] Two methods for reducing moving metal artifacts in cone-beam CT
    Hahn, Andreas
    Knaup, Michael
    Brehm, Marcus
    Sauppe, Sebastian
    Kachelriess, Marc
    MEDICAL PHYSICS, 2018, 45 (08) : 3671 - 3680
  • [49] Dependence of cone-beam CT artifacts on the frequency content of the imaged object
    Jaffray, D
    Clackdoyle, R
    Siewerdsen, J
    Noo, F
    MEDICAL PHYSICS, 2003, 30 (06) : 1407 - 1407
  • [50] Characterization and correction of cupping effect artefacts in cone beam CT
    Hunter, A. K.
    McDavid, W. D.
    DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (03) : 217 - 223