The effect of MV cone-beam CT cupping artifacts on dose calculation accuracy

被引:2
|
作者
Chen, J [1 ]
Morin, O [1 ]
Chen, H [1 ]
Aubin, M [1 ]
Pouliot, J [1 ]
机构
[1] Univ Calif San Francisco, Ctr Comprehens Canc, San Francisco, CA 94143 USA
关键词
D O I
10.1118/1.1997618
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: MV cone‐beam (CB) CT imaging can be used to position the patient prior to external‐beam radiotherapy. If calibrated, these images may also be used in dose calculations, opening the possibility to reconstruct the delivered dose or re‐optimize the treatment plan before delivery. This study investigates the effect of imaging artifacts on dosimetric accuracy. Method and Materials: Two water cylinders of 13 cm and 22.5 cm diameters were imaged using A) a MV CBCT system integrated with a Siemens accelerator and B) a conventional kV CT imager. Cupping trends observed in the MV CBCT were imposed on the kV CT images to create artificial data with simulated artifacts. Using the Phillips Pinnacle planning system, a 6 MV 10 × 16 cm2 field was applied to 1) the original kV CT of the smaller cylinder and 2) the kV CT with simulated artifacts. Similarly, a 18 × 18 cm2 field was applied to the original and artificial kV CT of the larger cylinder. Results: For the smaller cylinder, the MV CBCT water signal relative to air at the cylinder center differs from the radial and axial extremities by approximately 14% and 17% respectively. For the larger cylinder, the differences are 38% and 20% in radial and axial directions. The dose distributions for the artificial images show a systematic deviation which increases with depth. In the high‐dose, low‐gradient regions, the largest deviation for the smaller cylinder is 1% of the maximum delivered dose. For the larger cylinder, the largest deviation is 4%. Conclusion: Cupping artifacts in water phantoms produce dosimetric errors much smaller in magnitude than the cupping trend itself but as large as 4% for large phantoms. These results suggest that rough correction of MV CBCT artifacts may be sufficient for dosimetric accuracy. Conflict of Interest: Research supported by Siemens OCS. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1936 / 1936
页数:1
相关论文
共 50 条
  • [21] Cone-Beam Artifacts in Dedicated Breast CT
    Vedantham, S.
    Shi, L.
    Noo, F.
    Glick, S.
    Karellas, A.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [22] Shading correction for cone-beam CT in radiotherapy: Validation of dose calculation accuracy using clinical images
    Marchant, T. E.
    Joshi, K. D.
    Moore, C. J.
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [23] Dose Calculation Accuracy Using Cone-Beam CT (CBCT) for Lung Stereotactic Body Radiotherapy (SBRT)
    Xiong, W.
    Huang, Y.
    Gewanter, R.
    Dutta, P.
    Burman, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [24] Patient positioning, target delineation and dose calculation with MV cone-beam CT for patients with metallic implants: Clinical integration
    Aubin, Nni.
    Morin, O.
    Descovich, M.
    Speight, J.
    Gottschalk, A.
    Xia, P.
    Aubry, J.
    Verhey, L.
    Roach, M.
    Pouliot, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S668 - S669
  • [25] A Hybrid Approach to Reduce Cone-Beam Artifacts for a Circular Orbit Cone-Beam CT System
    Choi, Shinkook
    Kim, Jinsung
    Baek, Jongduk
    IEEE ACCESS, 2018, 6 : 54595 - 54606
  • [26] Parameterization of Scatter Dependent Artifacts in Cone-Beam CT
    Mail, N.
    Moseley, D.
    Jaffray, D.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [27] A Method to Estimate Cone-Beam CT Dose Index and Cone-Beam Dose Length Product
    Kim, S.
    Song, H.
    Samei, E.
    Yin, F.
    Yoshizumi, T.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [28] Use of GammaPlan convolution algorithm for dose calculation on CT and cone-beam CT images
    Ramachandran, Prabhakar
    Perrett, Ben
    Dancewicz, Orrie
    Seshadri, Venkatakrishnan
    Jones, Catherine
    Mehta, Akash
    Foote, Matthew
    RADIATION ONCOLOGY JOURNAL, 2021, 39 (02): : 129 - 138
  • [29] A level set method for cupping artifact correction in cone-beam CT
    Xie, Shipeng
    Li, Chunming
    Li, Haibo
    Ge, Qi
    MEDICAL PHYSICS, 2015, 42 (08) : 4888 - 4895
  • [30] Investigation of the accuracy of MV radiation isocentre calculations in the Elekta cone-beam CT software XVI
    Riis, Hans L.
    Moltke, Lars N.
    Zimmermann, Sune J.
    Ebert, Martin A.
    Rowshanfarzad, Pejman
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (11): : N249 - N256