摘要
Electrochemical detection of adenine (A) and guanine (G) using the self-assembled monolayer of copper(II)-thiophenyl-azo-imidazole modified gold electrode (Cu2+-IATP-Au) is reported. The self-assembled momolayer of 4-(2'-imidazolylazo) thiophenol (IATP) on a gold electrode surface was prepared by covalent immobilization of imidazole onto a 4-aminothiophenol monolayer modified gold electrode by a diazotization-coupling reaction. The catalyst was formed by immobilizing Cu(II) ion on the IATP modified gold electrode. The modified gold electrode was characterised by Field emission scanning electron microscopy, Energy dispersive X-ray analysis, Infrared spectroscopy, Cyclic voltammetry and Electrochemical Impedance spectroscopic techniques. The Cu2+-IATP-Au electrode exhibits excellent electrocatalytic activity towards the oxidation of A and G. Without separation or pre-treatment, the modified electrode can detect A and G simultaneously in a mixture and DNA samples. In the presence of excess common interferents such as ascorbic acid, citric acid, cysteine, glucose, Na+, K+, Cl-, SO42- had no effect on the peak current of A and G. In differential pulse voltammetry measurement, the oxidation current response of A and G was increased linearly in the concentration range 10-60 mu M and the detection limit was found to be 0.06 mu M and 0.01 mu M (S/N = 3), respectively. The proposed method was applied to determine adenine and guanine in herring sperm DNA and the result was satisfactory.
引用
收藏
页码:49819 / 49826
页数:8
相关论文
共 50 条
  • [41] Self-assembled monolayer modified gold electrodes for traces Cu(II) determination
    Profumo, A
    Merli, D
    Pesavento, M
    ANALYTICA CHIMICA ACTA, 2006, 557 (1-2) : 45 - 51
  • [42] Enantioselectivity of redox reaction of DOPA at the gold electrode modified with a self-assembled monolayer of homocysteine
    Nakanishi, Takuya
    Matsunaga, Mariko
    Nagasaka, Makoto
    Asahi, Toru
    Osaka, Tetsuya
    Journal of the American Chemical Society, 2006, 128 (41): : 13322 - 13323
  • [43] Electroanalysis of ascorbate and dopamine at a gold electrode modified with a positively charged self-assembled monolayer
    Raj, CR
    Ohsaka, T
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 496 (1-2) : 44 - 49
  • [44] Electroanalysis of dopamine at a gold electrode modified with N-acetylcysteine self-assembled monolayer
    Liu, T
    Li, MX
    Li, QY
    TALANTA, 2004, 63 (04) : 1053 - 1059
  • [45] Enantioselectivity of redox reaction of DOPA at the gold electrode modified with a self-assembled monolayer of homocysteine
    Nakanishi, Takuya
    Matsunaga, Mariko
    Nagasaka, Makoto
    Asahi, Toru
    Osaka, Tetsuya
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2006, 128 (41) : 13322 - 13323
  • [46] Electrochemical sensing of the secretion of indoxyl sulfate in a rat intestinal loop using a self-assembled monolayer-modified gold bead electrode
    Fujita, Kyoko
    Nonaka, Taisei
    Kutsuno, Rina
    Ichida, Kimiyoshi
    TALANTA, 2022, 247
  • [47] Preparation and optimization of a bienzymic biosensor based on self-assembled monolayer modified gold electrode for alcohol and glucose detection
    Asav, Engin
    Akyilmaz, Erol
    BIOSENSORS & BIOELECTRONICS, 2010, 25 (05): : 1014 - 1018
  • [48] Amperometric aptasensor for saxitoxin using a gold electrode modified with carbon nanotubes on a self-assembled monolayer, and methylene blue as an electrochemical indicator probe
    Li Hou
    Lingshan Jiang
    Yunping Song
    Yunhua Ding
    Jianhua Zhang
    Xiaoping Wu
    Dianping Tang
    Microchimica Acta, 2016, 183 : 1971 - 1980
  • [49] Amperometric aptasensor for saxitoxin using a gold electrode modified with carbon nanotubes on a self-assembled monolayer, and methylene blue as an electrochemical indicator probe
    Hou, Li
    Jiang, Lingshan
    Song, Yunping
    Ding, Yunhua
    Zhang, Jianhua
    Wu, Xiaoping
    Tang, Dianping
    MICROCHIMICA ACTA, 2016, 183 (06) : 1971 - 1980