Electrochemical detection of adenine and guanine using a self-assembled copper(II)-thiophenyl-azoimidazole complex monolayer modified gold electrode

被引:34
|
作者
Barman, Koushik [1 ]
Jasimuddin, Sk [1 ]
机构
[1] Assam Univ, Dept Chem, Silchar 788011, Assam, India
关键词
GLASSY-CARBON ELECTRODE; ELECTROCATALYTIC OXIDATION; COPPER(II) COMPLEX; COMPOSITE FILM; ASCORBIC-ACID; SENSOR; DNA; GRAPHENE; BEHAVIOR; PURINE;
D O I
10.1039/c4ra08568j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Electrochemical detection of adenine (A) and guanine (G) using the self-assembled monolayer of copper(II)-thiophenyl-azo-imidazole modified gold electrode (Cu2+-IATP-Au) is reported. The self-assembled momolayer of 4-(2'-imidazolylazo) thiophenol (IATP) on a gold electrode surface was prepared by covalent immobilization of imidazole onto a 4-aminothiophenol monolayer modified gold electrode by a diazotization-coupling reaction. The catalyst was formed by immobilizing Cu(II) ion on the IATP modified gold electrode. The modified gold electrode was characterised by Field emission scanning electron microscopy, Energy dispersive X-ray analysis, Infrared spectroscopy, Cyclic voltammetry and Electrochemical Impedance spectroscopic techniques. The Cu2+-IATP-Au electrode exhibits excellent electrocatalytic activity towards the oxidation of A and G. Without separation or pre-treatment, the modified electrode can detect A and G simultaneously in a mixture and DNA samples. In the presence of excess common interferents such as ascorbic acid, citric acid, cysteine, glucose, Na+, K+, Cl-, SO42- had no effect on the peak current of A and G. In differential pulse voltammetry measurement, the oxidation current response of A and G was increased linearly in the concentration range 10-60 mu M and the detection limit was found to be 0.06 mu M and 0.01 mu M (S/N = 3), respectively. The proposed method was applied to determine adenine and guanine in herring sperm DNA and the result was satisfactory.
引用
收藏
页码:49819 / 49826
页数:8
相关论文
共 50 条
  • [21] Electrochemical behavior of the bis(2,2′-bipyridyl) copper(II) complex immobilized on a self-assembled monolayer modified electrode for L-ascorbic acid detection
    Freire, RS
    Kubota, LT
    ANALYST, 2002, 127 (11) : 1502 - 1506
  • [22] Electrochemical Synthesis of CdS Nanocrystals on a Gold Electrode Modified with a p-Aminothiophenol Self-Assembled Monolayer
    Wang Hui
    Xi Yan-Yan
    Zhou Jian-Zhang
    Lin Zhong-Hua
    ACTA PHYSICO-CHIMICA SINICA, 2012, 28 (06) : 1398 - 1404
  • [23] Electrochemical study of a polypyrrole film/decanethiol self-assembled monolayer on a gold electrode
    Wang, J
    Zeng, BZ
    Fang, C
    He, F
    Zhou, XY
    ELECTROANALYSIS, 1999, 11 (18) : 1345 - 1349
  • [24] Electrochemical Behavior of Cytochrome C as a Self-Assembled Monolayer on a Porous Gold Electrode
    Wang, Gui-Xia
    Yang, Zhuo
    Li, Zhao-Hao
    Zhao, Bang-Tun
    ANALYTICAL LETTERS, 2015, 48 (06) : 982 - 995
  • [25] Formation kinetics and electrochemical behavior of an azobenzene self-assembled monolayer on a gold electrode
    Shao, HB
    Yu, HZ
    Cheng, GJ
    Zhang, HL
    Liu, ZF
    BERICHTE DER BUNSEN-GESELLSCHAFT-PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 1998, 102 (01): : 111 - 117
  • [26] Electrochemical impedance spectroscopy as a transduction method for electrochemical recognition of zirconium on gold electrode modified with hydroxamated self-assembled monolayer
    Shervedani, Reza Karimi
    Bagherzadeh, Mojtaba
    SENSORS AND ACTUATORS B-CHEMICAL, 2009, 139 (02): : 657 - 664
  • [27] Photoinduced electron transfer at a gold electrode modified with a self-assembled monolayer of fullerene
    Imahori, H
    Azuma, T
    Ozawa, S
    Yamada, H
    Ushida, K
    Ajavakom, A
    Norieda, H
    Sakata, Y
    CHEMICAL COMMUNICATIONS, 1999, (06) : 557 - 558
  • [28] Acid at Electrode Modified by Cystamine Self-assembled Monolayer with Gold Nanoparticles.
    Shaidarova, L. G.
    Romanova, E. I.
    Chelnokova, I. A.
    Gedmina, A. V.
    Budnikov, H. C.
    UCHENYE ZAPISKI KAZANSKOGO UNIVERSITETA-SERIYA ESTESTVENNYE NAUKI, 2010, 152 (01): : 71 - 78
  • [29] Coadsorption optimization of DNA in binary self-assembled monolayer on gold electrode for electrochemical detection of oligonucleotide sequences
    Ferrario, A.
    Scaramuzza, M.
    Pasqualotto, E.
    De Toni, A.
    Paccagnella, A.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 689 : 57 - 62
  • [30] Studies on the electrochemical behavior of a cystine self-assembled monolayer modified electrode using ferrocyanide as a probe
    Pedrosa, Valber A.
    Paixao, Thiago R. L. C.
    Freire, Renato S.
    Bertotti, Mauro
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 602 (02) : 149 - 155