Amperometric aptasensor for saxitoxin using a gold electrode modified with carbon nanotubes on a self-assembled monolayer, and methylene blue as an electrochemical indicator probe

被引:0
|
作者
Li Hou
Lingshan Jiang
Yunping Song
Yunhua Ding
Jianhua Zhang
Xiaoping Wu
Dianping Tang
机构
[1] Fuzhou University,Key Laboratory of Analysis and Detection for Food Safety (Ministry of Education & Fujian Province); College of Chemistry
[2] Radiation Environment Supervision Station of Fujian Province,undefined
来源
Microchimica Acta | 2016年 / 183卷
关键词
Aptamer based assay; Carbon nanotubes film electrode; Cyclic voltammetry; Marine toxin; Methylene blue; Mussel analysis; Differential pulse voltammetry; Gold-thiol chemistry;
D O I
暂无
中图分类号
学科分类号
摘要
A label-free electrochemical aptasensor was developed for selective detection of saxitoxin (STX). It is taking advantage of target-induced conformational change of an STX-specific aptamer when it binds to the toxin. A monolayer of octadecanethiol was deposited on a gold electrode, and then coated with a film of multiwalled carbon nanotubes (MWCNTs) to which the aptamer was covalently conjugated. Methylene blue (MB) was electrostatically anchored on carboxylated MWCNTs and used as the electrochemical indicator that produced a strong differential pulse voltammetric signal in the absence of target (STX). If, however, STX binds to its aptamer, this triggers a conformational change of the aptamer and results in the establishment of a barrier for heterogeneous electron transfer. The oxidation peak current of MB, acquired at −0.27 V (vs. Ag/AgCl), linearly decreases with increasing concentrations of STX in the 0.9 and 30 nM concentration range. The detection limit is 0.38 nM. Marine toxins that maybe present along with STX do not interfere even if they have a similar chemical structure. The assay was applied to the determination of STX in mussels samples and was found to be acceptably accurate. Hence, the method introduced here provides a rapid and sensitive tool for monitoring red tide pollution.
引用
收藏
页码:1971 / 1980
页数:9
相关论文
共 50 条
  • [1] Amperometric aptasensor for saxitoxin using a gold electrode modified with carbon nanotubes on a self-assembled monolayer, and methylene blue as an electrochemical indicator probe
    Hou, Li
    Jiang, Lingshan
    Song, Yunping
    Ding, Yunhua
    Zhang, Jianhua
    Wu, Xiaoping
    Tang, Dianping
    MICROCHIMICA ACTA, 2016, 183 (06) : 1971 - 1980
  • [2] AMPEROMETRIC DETERMINATION OF SURFACTANTS USING A GOLD ELECTRODE MODIFIED WITH A SELF-ASSEMBLED MONOLAYER OF STEARYLTHIOL
    KAWAGUCHI, T
    YAMAUCHI, Y
    MAEDA, H
    OHMORI, H
    ANALYTICAL SCIENCES, 1992, 8 (05) : 691 - 692
  • [3] ELECTROCHEMICAL CHARACTERISTICS OF A GOLD ELECTRODE MODIFIED WITH A SELF-ASSEMBLED MONOLAYER OF FERROCENYLALKANETHIOLS
    UOSAKI, K
    SATO, Y
    KITA, H
    LANGMUIR, 1991, 7 (07) : 1510 - 1514
  • [4] Studies on the electrochemical behavior of a cystine self-assembled monolayer modified electrode using ferrocyanide as a probe
    Pedrosa, Valber A.
    Paixao, Thiago R. L. C.
    Freire, Renato S.
    Bertotti, Mauro
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 602 (02) : 149 - 155
  • [5] Electrochemical behavior of gold electrode modified densely with self-assembled monolayer of ferrocenylalkanethiol
    Zhou Mi
    Zhu Jun-Jie
    Zhao Jian-Wei
    CHINESE JOURNAL OF INORGANIC CHEMISTRY, 2007, 23 (01) : 46 - 50
  • [6] Electrochemical detection of hybridization using peptide nucleic acids and methylene blue on self-assembled alkanethiol monolayer modified gold electrodes
    Ozkan, D
    Erdem, A
    Kara, P
    Kerman, K
    Gooding, JJ
    Nielsen, PE
    Ozsoz, M
    ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (10) : 796 - 802
  • [7] Electrochemical detection of copper(II) at a gold electrode modified with a self-assembled monolayer of penicillamine
    L. M. Niu
    H. Q. Luo
    N. B. Li
    L. Song
    Journal of Analytical Chemistry, 2007, 62 : 470 - 474
  • [8] Electrochemical detection of copper(II) at a gold electrode modified with a self-assembled monolayer of penicillamine
    Niu, L. M.
    Luo, H. Q.
    Li, N. B.
    Song, L.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 62 (05) : 470 - 474
  • [9] A micro amperometric immunosensor based on protein A/Gold nanoparticles/Self-assembled monolayer-modified gold electrode
    Xu, Yuanyuan
    Xia, Shanhong
    Bian, Chao
    Chen, Shaofeng
    2006 1ST IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1-3, 2006, : 38 - 41
  • [10] GOLD ELECTRODE MODIFIED WITH A SELF-ASSEMBLED MONOLAYER OF THIOLS AS AN ELECTROCHEMICAL DETECTOR FOR IONIC SURFACTANTS
    KAWAGUCHI, T
    YAMAUCHI, Y
    MAEDA, H
    OHMORI, H
    CHEMICAL & PHARMACEUTICAL BULLETIN, 1993, 41 (09) : 1601 - 1603