Self-assembled monolayer modified gold electrodes for traces Cu(II) determination

被引:25
|
作者
Profumo, A [1 ]
Merli, D [1 ]
Pesavento, M [1 ]
机构
[1] Univ Pavia, Dept Gen Chem, I-27100 Pavia, Italy
关键词
self-assembled monolayers; D; L-penicillamine SAM; thiodimethylglyoxime SAM; Cu determination; adsorptive stripping analysis;
D O I
10.1016/j.aca.2005.10.037
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
D,L-Penicillamine and thiodimethylglyoxime (TDMG) self-assembled monolayers (SAMs) on gold electrode were prepared and characterized by electrochemical measurements. The two sensors exhibit sensitive and selective response to Cu(II), both forming 2:1 complexes, the first one in acetic buffer and the second one in ammonia buffer. Copper determination at trace level (LOQ 0.2 and 0.3 mu g/L for D,L-penicillamine and TDMG, respectively) is possible with both the electrodes as verified in tap, spring and sea water. The influence on copper determination of most common ions present in natural waters and of organic matter has been investigated. Accuracy was checked by recovery test on spiked samples. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:45 / 51
页数:7
相关论文
共 50 条
  • [2] Voltammetric response of glutathione and 3-mercaptopropionic acid self-assembled monolayer modified gold electrodes to Cu(II)
    Zeng, BZ
    Ding, XG
    Zhao, FQ
    ELECTROANALYSIS, 2002, 14 (10) : 651 - 656
  • [3] Electrochemistry and electrocatalytic activities of superoxide dismutases at gold electrodes modified with a self-assembled monolayer
    Tian, Y
    Mao, LQ
    Okajima, T
    Ohsaka, T
    ANALYTICAL CHEMISTRY, 2004, 76 (14) : 4162 - 4168
  • [4] Self-assembled gold nanoparticles modified ITO electrodes: The monolayer binder molecule effect
    Ballarin, Barbara
    Cassani, Maria Cristina
    Scavetta, Erika
    Tonelli, Domenica
    ELECTROCHIMICA ACTA, 2008, 53 (27) : 8034 - 8044
  • [5] Self-assembled monolayer and multilayer films with polyoxometalates on gold electrodes
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao, 5 Suppl (163):
  • [6] Electrocatalytic oxidation of hydroquinone with Cu2+ modified gold-L-cysteine self-assembled monolayer electrodes
    Barman, Kaushik
    Jasimuddin, Sk
    INDIAN JOURNAL OF CHEMISTRY SECTION A-INORGANIC BIO-INORGANIC PHYSICAL THEORETICAL & ANALYTICAL CHEMISTRY, 2013, 52 (02): : 217 - 220
  • [7] Selective detection of dopamine in urine with electrodes modified by gold nanodendrite and anionic self-assembled monolayer
    Tsai, Tien-Chun
    Huang, Fei-Ho
    Chen, Jia-Jin Jason
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 181 : 179 - 186
  • [8] Characterization of the Iron Species Released by Ferritin Immobilized on Self-Assembled Monolayer Modified Gold Electrodes
    Ritzert, Nicole L.
    Lukus, Peter A.
    Scott, Brandon L.
    Zapien, Donald C.
    ANALYTICAL LETTERS, 2020, 53 (04) : 509 - 521
  • [9] Improvement of alternariol monomethyl ether detection at gold electrodes modified with a dodecanethiol self-assembled monolayer
    Moressi, MB
    Andreu, R
    Calvente, JJ
    Fernández, H
    Zón, MA
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2004, 570 (02) : 209 - 217
  • [10] Nanomolar scale nitric oxide generation from self-assembled monolayer modified gold electrodes
    Hou, YC
    Chen, YS
    Amro, NA
    Wadu-Mesthrige, K
    Andreana, PR
    Liu, G
    Wang, PG
    CHEMICAL COMMUNICATIONS, 2000, (19) : 1831 - 1832