Diffusion-weighted imaging of the spine with a non-Carr-Purcell-Meiboom-Gill single-shot fast spin-echo sequence: Initial experience

被引:0
|
作者
Oner, A. Y. [1 ]
Tali, T.
Celikyay, F.
Celik, A.
Le Roux, P.
机构
[1] Gazi Univ, Sch Med, Dept Radiol, TR-06510 Ankara, Turkey
[2] GE Med Syst, Istanbul, Turkey
[3] GE Healthcare, Global Appl Sci Lab, Buc, France
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: To prospectively evaluate the signal-to-noise ratio (SNR) improvement in diffusion-weighted imaging (DWI) of the spine with the use of a newly developed non-Carr-Purcell-Meiboom-Gill (non-CPMG) single-shot fast spin-echo (SS-FSE) sequence and its effect on apparent diffusion coefficient (ADC) measurements. MATERIALS AND METHODS: Twenty-four patients were enrolled after written informed consent. DWI of the spine was obtained with an echo-planar imaging (EPI)-based sequence followed by a non-CPMG SS-FSE technique. SNR and ADC values were measured over a lesion-free vertebral corpus. A quality score was assigned for each set of images to assess the image quality. When a spinal lesion was present, contrast-to-noise ratio (CNR) and ADC were also measured. Student t tests were used for statistical analysis. RESULTS: Mean SNR values were 5.83 +/- 2.2 and 11.68 +/- 2.87 for EPI and non-CPMG SS-FSE DWI, respectively. SNR values measured in DWI using parallel imaging were found to be significantly higher(P < .01). Mean ADCs of the spine were 0.53 +/- 0.15 and 0.35 +/- 0.15 X 10(-3) mm(2)/s for EPI and non-CPMG SS-FSE DWI, respectively. Quality scores were found to be higher for the non-CPMG SS-FSE DWI technique (P < .05). Overall lesion CNR was found to be higher in DWI with non-CPMG SS-FSE. CONCLUSION: The non-CPMG SS-FSE technique provides a significant improvement to current EPI-based DWI of the spine. A study including a larger number of patients is required to determine the use of this DWI sequence as a supplementary tool to conventional MR imaging for increasing diagnostic confidence in spinal pathologic conditions.
引用
收藏
页码:575 / 580
页数:6
相关论文
共 50 条
  • [41] Comparison of diffusion-weighted imaging and T2-weighted single shot fast spin-echo: Implications for LI-RADS characterization of hepatocellular carcinoma
    Hicks, Robert M.
    Yee, Judy
    Ohliger, Michael A.
    Weinstein, Stefanie
    Kao, Jeffrey
    Ikram, Nabia S.
    Hope, Thomas A.
    MAGNETIC RESONANCE IMAGING, 2016, 34 (07) : 915 - 921
  • [42] T-staging of rectal cancer: Utility of single-shot turbo spin-echo diffusion-weighted imaging with T2-weighted images and fusion images
    Ogawa, Masaki
    Urano, Misugi
    Takaishi, Taku
    Kan, Hirohito
    Arai, Nobuyuki
    Takahashi, Hiroki
    Hara, Masayasu
    Saito, Miki
    Shibamoto, Yuta
    PLOS ONE, 2021, 16 (04):
  • [43] Differential diagnosis of pancreatic cancer by single-shot echo-planar imaging diffusion-weighted imaging
    Hong, Ben-Zu
    Li, Xin-Feng
    Lin, Jian-Qing
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (20) : 6374 - 6380
  • [44] Differential diagnosis of pancreatic cancer by single-shot echo-planar imaging diffusion-weighted imaging
    Ben-Zu Hong
    Xin-Feng Li
    Jian-Qing Lin
    World Journal of Gastroenterology, 2015, (20) : 6374 - 6380
  • [45] Comparison of ultrafast half-Fourier single-shot turbo spin-echo sequence with turbo spin-echo sequences for T2-weighted imaging of the female pelvis
    Yamashita, Y
    Tang, Y
    Abe, Y
    Mitsuzaki, K
    Takahashi, M
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (06): : 1207 - 1212
  • [46] Rapid multi-echo measurement of brain metabolite T2 values at 7 T using a single-shot spectroscopic Carr-Purcell-Meiboom-Gill sequence and prior information
    Ronen, Itamar
    Ercan, Ece
    Webb, Andrew
    NMR IN BIOMEDICINE, 2013, 26 (10) : 1291 - 1298
  • [47] T2-weighted MRI of rectosigmoid carcinoma: Comparison of respiratory-triggered fast spin-echo, breathhold fast-recovery fast spin-echo, and breathhold single-shot fast spin-echo sequences
    Yamashita, Shuhei
    Masui, Takayuki
    Katayama, Motoyuki
    Sato, Kimihiko
    Yoshizawa, Nobuko
    Seo, Hidekazu
    Sakahara, Harumi
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (03) : 511 - 516
  • [48] Diffusion-Weighted MR Imaging in Head and Neck Cancer: Comparison between Half-Fourier Acquired Single-Shot Turbo Spin-Echo and EPI Techniques
    Verhappen, M. H.
    Pouwels, P. J. W.
    Ljumanovic, R.
    van der Putten, L.
    Knol, D. L.
    De Bree, R.
    Castelijns, J. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (07) : 1239 - 1246
  • [49] Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: preliminary clinical experience in 61 patients
    Ichikawa, T
    Haradome, H
    Hachiya, J
    Nitatori, T
    Araki, T
    ABDOMINAL IMAGING, 1999, 24 (05): : 456 - 461
  • [50] Comparison of multiplexed sensitivity encoding and single-shot echo-planar imaging for diffusion-weighted imaging of the liver
    Kim, Yeun-Yoon
    Kim, Myeong-Jin
    Gho, Sung-Min
    Seo, Nieun
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 132