Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: preliminary clinical experience in 61 patients

被引:140
|
作者
Ichikawa, T
Haradome, H
Hachiya, J
Nitatori, T
Araki, T
机构
[1] Yamanashi Med Univ, Dept Radiol, 1110 Shimokato, Yamanashi 40938, Japan
[2] Kyorin Univ, Sch Med, Dept Radiol, Tokyo 181, Japan
来源
ABDOMINAL IMAGING | 1999年 / 24卷 / 05期
关键词
abdomen; magnetic resonance; liver; rapid imaging; diffusion study; echo planar;
D O I
10.1007/s002619900539
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: To determine the potential ability of diffusion-weighted magnetic resonance (MR) imaging with single-shot echo-planar imaging (DW imaging) in the upper abdomen by apparent diffusion coefficient (ADC) and signal:intensity ratio (SIR) measurements. Methods: DW imaging was performed in 61 clinical patients. ADCs in the liver, pancreas, spleen, kidney, and different pathological conditions were calculated. Spleen-to-liver SIR and segmental intensity difference of the liver (SID) were also calculated. Results: The mean ADCs (mm(2)/s) were 2.28 x 10(-3) +/- 0.07 in the liver, 1.44 x 10(-3) +/- 0.05 in the spleen, 1.94 x 10(-3) +/- 0.19 in the pancreas, and 5.76 x 10(-3) +/- 0.06 in the kidney. The mean ADC of cirrhotic liver was 1.96 x 10(-3) +/- 0.62, which was lower than that of normal liver. Other pathologic conditions also showed ADCs different from those of normal tissues. All DW images showed significantly higher spleen-to-liver SIRs and SIDs than did T2-weighted images (p < 0.05). Conclusion: The mean ADCs obtained with DW imaging were different in each upper abdominal organ and with each pathologic condition. DW images showed: better soft tissue contrast than did T2-weighted images with regard to SIR and CNR in depicting and characterizing upper abdominal disorders.
引用
收藏
页码:456 / 461
页数:6
相关论文
共 50 条
  • [1] Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: preliminary clinical experience in 61 patients
    T. Ichikawa
    H. Haradome
    J. Hachiya
    T. Nitatori
    T. Araki
    Abdominal Imaging, 1999, 24 : 456 - 461
  • [2] Detection of Middle Ear Cholesteatoma by Diffusion-Weighted MR Imaging: Multishot Echo-Planar Imaging Compared with Single-Shot Echo-Planar Imaging
    Yamashita, K.
    Yoshiura, T.
    Hiwatashi, A.
    Kamano, H.
    Dashjamts, T.
    Shibata, S.
    Tamae, A.
    Honda, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (10) : 1915 - 1918
  • [3] Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality
    Kim, Yun Ju
    Kim, Sung Hun
    Kang, Bong Joo
    Park, Chang Suk
    Kim, Hyeon Sook
    Son, Yo Han
    Porter, David Andrew
    Song, Byung Joo
    KOREAN JOURNAL OF RADIOLOGY, 2014, 15 (04) : 403 - 410
  • [4] Differential diagnosis of pancreatic cancer by single-shot echo-planar imaging diffusion-weighted imaging
    Hong, Ben-Zu
    Li, Xin-Feng
    Lin, Jian-Qing
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (20) : 6374 - 6380
  • [5] Differential diagnosis of pancreatic cancer by single-shot echo-planar imaging diffusion-weighted imaging
    Ben-Zu Hong
    Xin-Feng Li
    Jian-Qing Lin
    World Journal of Gastroenterology, 2015, (20) : 6374 - 6380
  • [6] Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: Comparison with single-shot echo-planar diffusion-weighted sequences
    Xia, Chun-chao
    Liu, Xi
    Peng, Wan-lin
    Li, Lei
    Zhang, Jin-ge
    Meng, Wen-jian
    Deng, Xiang-bing
    Zuo, Pan-li
    Li, Zhen-lin
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (10) : 1818 - 1823
  • [7] Readout-segmented echo-planar imaging in diffusion-weighted MR imaging of acute infarction of the brainstem and posterior fossa: comparison of single-shot echo-planar diffusion-weighted sequences
    Byeon, Jonghyun
    Kim, Jee Young
    Cho, A-Hyun
    CLINICAL IMAGING, 2015, 39 (05) : 765 - 769
  • [8] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Wu, Chen-Jiang
    Wang, Qing
    Zhang, Jing
    Wang, Xiao-Ning
    Liu, Xi-Sheng
    Zhang, Yu-Dong
    Shi, Hai-Bin
    ABDOMINAL RADIOLOGY, 2016, 41 (01) : 100 - 108
  • [9] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Chen-Jiang Wu
    Qing Wang
    Jing Zhang
    Xiao-Ning Wang
    Xi-Sheng Liu
    Yu-Dong Zhang
    Hai-Bin Shi
    Abdominal Radiology, 2016, 41 : 100 - 108
  • [10] Comparing the clinical utility of single-shot echo-planar imaging and readout-segmented echo-planar imaging in diffusion-weighted imaging of the liver at 3 tesla
    Xie, Simin
    Masokano, Ismail Bilal
    Liu, Wenguang
    Long, Xueying
    Li, Guijin
    Pei, Yigang
    Li, Wenzheng
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 135