Diffusion-weighted MR imaging with single-shot echo-planar imaging in the upper abdomen: preliminary clinical experience in 61 patients

被引:140
|
作者
Ichikawa, T
Haradome, H
Hachiya, J
Nitatori, T
Araki, T
机构
[1] Yamanashi Med Univ, Dept Radiol, 1110 Shimokato, Yamanashi 40938, Japan
[2] Kyorin Univ, Sch Med, Dept Radiol, Tokyo 181, Japan
来源
ABDOMINAL IMAGING | 1999年 / 24卷 / 05期
关键词
abdomen; magnetic resonance; liver; rapid imaging; diffusion study; echo planar;
D O I
10.1007/s002619900539
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: To determine the potential ability of diffusion-weighted magnetic resonance (MR) imaging with single-shot echo-planar imaging (DW imaging) in the upper abdomen by apparent diffusion coefficient (ADC) and signal:intensity ratio (SIR) measurements. Methods: DW imaging was performed in 61 clinical patients. ADCs in the liver, pancreas, spleen, kidney, and different pathological conditions were calculated. Spleen-to-liver SIR and segmental intensity difference of the liver (SID) were also calculated. Results: The mean ADCs (mm(2)/s) were 2.28 x 10(-3) +/- 0.07 in the liver, 1.44 x 10(-3) +/- 0.05 in the spleen, 1.94 x 10(-3) +/- 0.19 in the pancreas, and 5.76 x 10(-3) +/- 0.06 in the kidney. The mean ADC of cirrhotic liver was 1.96 x 10(-3) +/- 0.62, which was lower than that of normal liver. Other pathologic conditions also showed ADCs different from those of normal tissues. All DW images showed significantly higher spleen-to-liver SIRs and SIDs than did T2-weighted images (p < 0.05). Conclusion: The mean ADCs obtained with DW imaging were different in each upper abdominal organ and with each pathologic condition. DW images showed: better soft tissue contrast than did T2-weighted images with regard to SIR and CNR in depicting and characterizing upper abdominal disorders.
引用
收藏
页码:456 / 461
页数:6
相关论文
共 50 条
  • [31] Perfusion-weighted MR imaging in the upper abdomen: Preliminary clinical experience in 61 patients
    Ichikawa, T
    Haradome, H
    Hachiya, J
    Nitatori, T
    Araki, T
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (04) : 1061 - 1066
  • [32] Qualitative and quantitative comparison of image quality between single-shot echo-planar and interleaved multi-shot echo-planar diffusion-weighted imaging in female pelvis
    An, He
    Ma, Xiaodong
    Pan, Ziyi
    Guo, Hua
    Lee, Elaine Yuen Phin
    EUROPEAN RADIOLOGY, 2020, 30 (04) : 1876 - 1884
  • [33] Optimising diffusion-weighted imaging in the abdomen and pelvis: comparison of image quality between monopolar and bipolar single-shot spin-echo echo-planar sequences
    Kyriazi, Stavroula
    Blackledge, Matthew
    Collins, David J.
    deSouza, Nandita M.
    EUROPEAN RADIOLOGY, 2010, 20 (10) : 2422 - 2431
  • [34] Optimising diffusion-weighted imaging in the abdomen and pelvis: comparison of image quality between monopolar and bipolar single-shot spin-echo echo-planar sequences
    Stavroula Kyriazi
    Matthew Blackledge
    David J. Collins
    Nandita M. deSouza
    European Radiology, 2010, 20 : 2422 - 2431
  • [35] Diffusion-weighted echo-planar MR imaging: clinical applications and pitfalls - A pictorial essay
    Moritani, T
    Shrier, DA
    Numaguchi, Y
    Takase, Y
    Takahashi, C
    Wang, HZ
    Shibata, DK
    Abe, T
    Ukisu, R
    Ohgiya, Y
    Tsuchiya, A
    Kushihashi, T
    Gokan, T
    Munechika, H
    CLINICAL IMAGING, 2000, 24 (04) : 181 - 192
  • [36] Single-shot T2-weighted MR imaging of the upper abdomen: Preliminary experience with double-echo HASTE technique
    Bosmans, H
    VanHoe, L
    Gryspeerdt, S
    Kiefer, B
    VanSteenbergen, W
    Baert, AL
    Marchal, G
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (05) : 1291 - 1293
  • [37] Readout-segmented echo-planar diffusion-weighted imaging in the assessment of orbital tumors: comparison with conventional single-shot echo-planar imaging in image quality and diagnostic performance
    Xu, Xiaoquan
    Wang, Yanjun
    Hu, Hao
    Su, Guoyi
    Liu, Hu
    Shi, Haibin
    Wu, Feiyun
    ACTA RADIOLOGICA, 2017, 58 (12) : 1457 - 1467
  • [38] Multiplexed sensitivity-encoding versus single-shot echo-planar imaging: a comparative study for diffusion-weighted imaging of the thyroid lesions
    Xiuyu Wang
    Peng Wang
    Heng Zhang
    Xian Wang
    Jie Shi
    Shudong Hu
    Japanese Journal of Radiology, 2024, 42 : 268 - 275
  • [39] Prospective Comparison of FOCUS MUSE and Single-Shot Echo-Planar Imaging for Diffusion-Weighted Imaging in Evaluating Thyroid-Associated Ophthalmopathy
    Wang, YunMeng
    Cui, YuanYuan
    Dai, JianKun
    Ni, ShuangShuang
    Zhang, TianRan
    Chen, Xin
    Jiang, QinLing
    Cheng, YuXin
    Ma, YiChuan
    Li, Tuo
    Xiao, Yi
    KOREAN JOURNAL OF RADIOLOGY, 2024, 25 (10) : 913 - 923
  • [40] Multiplexed sensitivity-encoding versus single-shot echo-planar imaging: a comparative study for diffusion-weighted imaging of the thyroid lesions
    Wang, Xiuyu
    Wang, Peng
    Zhang, Heng
    Wang, Xian
    Shi, Jie
    Hu, Shudong
    JAPANESE JOURNAL OF RADIOLOGY, 2024, 42 (03) : 268 - 275