BACKGROUND AND PURPOSE: To prospectively evaluate the signal-to-noise ratio (SNR) improvement in diffusion-weighted imaging (DWI) of the spine with the use of a newly developed non-Carr-Purcell-Meiboom-Gill (non-CPMG) single-shot fast spin-echo (SS-FSE) sequence and its effect on apparent diffusion coefficient (ADC) measurements. MATERIALS AND METHODS: Twenty-four patients were enrolled after written informed consent. DWI of the spine was obtained with an echo-planar imaging (EPI)-based sequence followed by a non-CPMG SS-FSE technique. SNR and ADC values were measured over a lesion-free vertebral corpus. A quality score was assigned for each set of images to assess the image quality. When a spinal lesion was present, contrast-to-noise ratio (CNR) and ADC were also measured. Student t tests were used for statistical analysis. RESULTS: Mean SNR values were 5.83 +/- 2.2 and 11.68 +/- 2.87 for EPI and non-CPMG SS-FSE DWI, respectively. SNR values measured in DWI using parallel imaging were found to be significantly higher(P < .01). Mean ADCs of the spine were 0.53 +/- 0.15 and 0.35 +/- 0.15 X 10(-3) mm(2)/s for EPI and non-CPMG SS-FSE DWI, respectively. Quality scores were found to be higher for the non-CPMG SS-FSE DWI technique (P < .05). Overall lesion CNR was found to be higher in DWI with non-CPMG SS-FSE. CONCLUSION: The non-CPMG SS-FSE technique provides a significant improvement to current EPI-based DWI of the spine. A study including a larger number of patients is required to determine the use of this DWI sequence as a supplementary tool to conventional MR imaging for increasing diagnostic confidence in spinal pathologic conditions.
机构:
Houju Mem Hosp, Diagnost Imaging Room,11-71 Midorigaoka, Nomi, Ishikawa 9231226, Japan
Kanazawa Med Univ Hosp, Cent Radiat Dept, 1-1 Uchinada, Kahoku, Ishikawa 9200293, JapanHouju Mem Hosp, Diagnost Imaging Room,11-71 Midorigaoka, Nomi, Ishikawa 9231226, Japan
Bessho, Takahito
Hayashi, Tatsuya
论文数: 0引用数: 0
h-index: 0
机构:
Teikyo Univ, Grad Sch Med Technol, 2-11-1 Kaga,Itabashi Ku, Tokyo, Tokyo 1738605, JapanHouju Mem Hosp, Diagnost Imaging Room,11-71 Midorigaoka, Nomi, Ishikawa 9231226, Japan
Hayashi, Tatsuya
Shibukawa, Shuhei
论文数: 0引用数: 0
h-index: 0
机构:
Juntendo Univ, Fac Hlth Sci, Dept Radiol Technol, 2-1-1 Hongo,Bunkyo-Ku, Tokyo 1138421, JapanHouju Mem Hosp, Diagnost Imaging Room,11-71 Midorigaoka, Nomi, Ishikawa 9231226, Japan
Shibukawa, Shuhei
Kourin, Kazuyuki
论文数: 0引用数: 0
h-index: 0
机构:
Houju Mem Hosp, Diagnost Imaging Room,11-71 Midorigaoka, Nomi, Ishikawa 9231226, JapanHouju Mem Hosp, Diagnost Imaging Room,11-71 Midorigaoka, Nomi, Ishikawa 9231226, Japan
Kourin, Kazuyuki
Shouda, Takashi
论文数: 0引用数: 0
h-index: 0
机构:
Houju Mem Hosp, Diagnost Imaging Room,11-71 Midorigaoka, Nomi, Ishikawa 9231226, JapanHouju Mem Hosp, Diagnost Imaging Room,11-71 Midorigaoka, Nomi, Ishikawa 9231226, Japan
机构:
Stanford Univ, Dept Bioengn, Stanford, CA 94305 USA
Stanford Univ, Dept Elect Engn, Magnet Resonance Syst Res Lab, Stanford, CA 94305 USAStanford Univ, Dept Bioengn, Stanford, CA 94305 USA
Gibbons, Eric K.
Vasanawala, Shreyas S.
论文数: 0引用数: 0
h-index: 0
机构:
Stanford Univ, Dept Radiol, Stanford, CA 94305 USAStanford Univ, Dept Bioengn, Stanford, CA 94305 USA
Vasanawala, Shreyas S.
Pauly, John M.
论文数: 0引用数: 0
h-index: 0
机构:
Stanford Univ, Dept Elect Engn, Magnet Resonance Syst Res Lab, Stanford, CA 94305 USAStanford Univ, Dept Bioengn, Stanford, CA 94305 USA
Pauly, John M.
Kerr, Adam B.
论文数: 0引用数: 0
h-index: 0
机构:
Stanford Univ, Dept Elect Engn, Magnet Resonance Syst Res Lab, Stanford, CA 94305 USAStanford Univ, Dept Bioengn, Stanford, CA 94305 USA