Diffusion-weighted imaging of the spine with a non-Carr-Purcell-Meiboom-Gill single-shot fast spin-echo sequence: Initial experience

被引:0
|
作者
Oner, A. Y. [1 ]
Tali, T.
Celikyay, F.
Celik, A.
Le Roux, P.
机构
[1] Gazi Univ, Sch Med, Dept Radiol, TR-06510 Ankara, Turkey
[2] GE Med Syst, Istanbul, Turkey
[3] GE Healthcare, Global Appl Sci Lab, Buc, France
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: To prospectively evaluate the signal-to-noise ratio (SNR) improvement in diffusion-weighted imaging (DWI) of the spine with the use of a newly developed non-Carr-Purcell-Meiboom-Gill (non-CPMG) single-shot fast spin-echo (SS-FSE) sequence and its effect on apparent diffusion coefficient (ADC) measurements. MATERIALS AND METHODS: Twenty-four patients were enrolled after written informed consent. DWI of the spine was obtained with an echo-planar imaging (EPI)-based sequence followed by a non-CPMG SS-FSE technique. SNR and ADC values were measured over a lesion-free vertebral corpus. A quality score was assigned for each set of images to assess the image quality. When a spinal lesion was present, contrast-to-noise ratio (CNR) and ADC were also measured. Student t tests were used for statistical analysis. RESULTS: Mean SNR values were 5.83 +/- 2.2 and 11.68 +/- 2.87 for EPI and non-CPMG SS-FSE DWI, respectively. SNR values measured in DWI using parallel imaging were found to be significantly higher(P < .01). Mean ADCs of the spine were 0.53 +/- 0.15 and 0.35 +/- 0.15 X 10(-3) mm(2)/s for EPI and non-CPMG SS-FSE DWI, respectively. Quality scores were found to be higher for the non-CPMG SS-FSE DWI technique (P < .05). Overall lesion CNR was found to be higher in DWI with non-CPMG SS-FSE. CONCLUSION: The non-CPMG SS-FSE technique provides a significant improvement to current EPI-based DWI of the spine. A study including a larger number of patients is required to determine the use of this DWI sequence as a supplementary tool to conventional MR imaging for increasing diagnostic confidence in spinal pathologic conditions.
引用
收藏
页码:575 / 580
页数:6
相关论文
共 50 条
  • [31] Optimising diffusion-weighted imaging in the abdomen and pelvis: comparison of image quality between monopolar and bipolar single-shot spin-echo echo-planar sequences
    Kyriazi, Stavroula
    Blackledge, Matthew
    Collins, David J.
    deSouza, Nandita M.
    EUROPEAN RADIOLOGY, 2010, 20 (10) : 2422 - 2431
  • [32] Optimising diffusion-weighted imaging in the abdomen and pelvis: comparison of image quality between monopolar and bipolar single-shot spin-echo echo-planar sequences
    Stavroula Kyriazi
    Matthew Blackledge
    David J. Collins
    Nandita M. deSouza
    European Radiology, 2010, 20 : 2422 - 2431
  • [33] Optimized outer volume suppression for single-shot fast spin-echo cardiac imaging
    Le Roux, P
    Gilles, RJ
    McKinnon, GC
    Carlier, PG
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (05): : 1022 - 1032
  • [34] Rathke’s cleft cysts: differentiation from other cystic lesions in the pituitary fossa by use of single-shot fast spin-echo diffusion-weighted MR imaging
    N. Kunii
    T. Abe
    M. Kawamo
    D. Tanioka
    H. Izumiyama
    T. Moritani
    Acta Neurochirurgica, 2007, 149 : 759 - 769
  • [35] Rathke's cleft cysts: differentiation from other cystic lesions in the pituitary fossa by use of single-shot fast spin-echo diffusion-weighted MR imaging
    Kunii, N.
    Abe, T.
    Kawamo, M.
    Tanioka, D.
    Izumiyama, H.
    Moritani, T.
    ACTA NEUROCHIRURGICA, 2007, 149 (08) : 759 - 769
  • [36] Single-shot fast spin-echo diffusion tensor imaging of the brain and spine with head and phased array coils at 1.5 T and 3.0 T
    Xu, D
    Henry, RG
    Mukherjee, P
    Carvajal, L
    Miller, SP
    Barkovich, AJ
    Vigneron, DB
    MAGNETIC RESONANCE IMAGING, 2004, 22 (06) : 751 - 759
  • [37] Diffusion-weighted imaging of the spinal cord: Interleaved echo-planar imaging is superior to fast spin-echo
    Bammer, R
    Augustin, M
    Prokesch, RW
    Stollberger, R
    Fazekas, F
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2002, 15 (04) : 364 - 373
  • [38] Turbo Spin-echo Diffusion-weighted Imaging Compared with Single-shot Echo-planar Diffusion-weighted Imaging: Image Quality and Diagnostic Performance When Differentiating between Ductal Carcinoma in situ and Invasive Ductal Carcinoma
    Mori, Naoko
    Mugikura, Shunji
    Miyashita, Minoru
    Mori, Yu
    Maekawa, Yui
    Nagasaka, Tatsuo
    Takase, Kei
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (01) : 60 - 68
  • [40] Image quality assessment of single-shot turbo spin echo diffusion-weighted imaging with parallel imaging technique: a phantom study
    Yoshida, Tsukasa
    Urikura, Atsushi
    Shirata, Kensei
    Nakaya, Yoshihiro
    Terashima, Shingo
    Hosokawa, Yoichiro
    BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1065):