Relationship between outdoor and indoor air quality in eight French schools

被引:254
|
作者
Blondeau, P [1 ]
Iordache, V [1 ]
Poupard, O [1 ]
Genin, D [1 ]
Allard, F [1 ]
机构
[1] Univ La Rochelle, LEPTAB, F-17042 La Rochelle 1, France
关键词
I/O ratios; ozone; nitrogen oxides; particle size distribution; school; building air-tightness; ventilation;
D O I
10.1111/j.1600-0668.2004.00263.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the frame of the French national research program PRIMEQUAL (inter-ministry program for better air quality in urban environments), measurements of outdoor and indoor pollution have been carried out in eight schools in La Rochelle (France) and its suburbs. The buildings were naturally ventilated by opening the windows, or mechanically ventilated, and showed various air permeabilities. Ozone, nitrogen oxides (NO and NO2), and airborne particle (particle counts within 15 size intervals ranging from 0.3 to 15 mum) concentrations were continuously monitored indoors and outdoors for two 2-week periods. The indoor humidity, temperature, CO2 concentration (an indicator of occupancy), window openings and building permeability were also measured. The temporal profiles of indoor and outdoor concentrations show ozone and nitrogen oxides behave differently: NO and NO2 indoor/outdoor concentration ratios (I/O) were found to vary in a range from 0.5 to 1, and from 0.88 to 1, respectively, but no correlation with building permeability was observed. On the contrary, I/O ratios of ozone vary in a range from 0 to 0.45 and seem to be strongly influenced by the building air-tightness: the more airtight the building envelope, the lower the ratio. Occupancy, through re-suspension of previously deposited particles and possible particle generation, strongly influences the indoor concentration level of airborne particles. However, this influence decreases with particle size, reflecting the way deposition velocities vary as a function of size. The influence of particle size on deposition and penetration across the building envelope is also discussed by analyzing the I/O ratios measured when the buildings were unoccupied, by comparing the indoor concentrations measured when the buildings were occupied and when they were not (O/U ratios), and by referring to previously published studies focussing on this topic. Except one case, I/O were found to vary in the range from 0.03 to 1.79. All O/U are greater than one and increase up to 100 with particle size.
引用
收藏
页码:2 / 12
页数:11
相关论文
共 50 条
  • [41] Indoor and outdoor air quality investigation at universities in Wuhan
    Ye, Xiaojiang
    Chen, Huanxin
    Zhou, Zhaoxia
    Lian, Zhiwei
    PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 470 - 475
  • [42] Air quality assessment in indoor and outdoor environments: A review
    Prabhakaran, J.
    Jayabal, S.
    Kumar, A. Ramesh
    Vinoth, V.
    MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 1260 - 1266
  • [43] Wildfire Impact on Indoor and Outdoor PAH Air Quality
    Ghetu, Christine C.
    Rohlman, Diana
    Smith, Brian W.
    Scott, Richard P.
    Adams, Kaley A.
    Hoffman, Peter D.
    Anderson, Kim A.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2022, 56 (14) : 10042 - 10052
  • [44] Indoor versus Outdoor Air Quality during Wildfires
    Messier, K. P.
    Tidwell, L. G.
    Ghetu, C. C.
    Rohlman, D.
    Scott, R. P.
    Bramer, L. M.
    Dixon, H. M.
    Waters, K. M.
    Anderson, K. A.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS, 2019, 6 (12) : 696 - 701
  • [45] Indoor-Outdoor Air Quality Assessment in Nurseries
    Abu Mansor, Amalina
    Hisham, Ain Natasha Badrul
    Abdullah, Samsuri
    Napi, Nur Nazmi Liyana Mohd
    Ahmed, Ali Najah
    Ismail, Marzuki
    2ND INTERNATIONAL CONFERENCE ON GREEN ENVIRONMENTAL ENGINEERING AND TECHNOLOGY, 2020, 616
  • [46] The relationship between outdoor air quality and respiratory symptoms in young children
    Rodriguez, C.
    Hinwood, A.
    Tonkin, R.
    Heyworth, J.
    Kusel, M.
    Deklerk, N.
    Sly, P.
    Franklin, P.
    Runnion, T.
    Blockley, A.
    Landau, L.
    EPIDEMIOLOGY, 2006, 17 (06) : S107 - S107
  • [47] Special Issue: Indoor/Outdoor Airflow and Air Quality
    Yang, Xudong
    Zhao, Bin
    BUILDING SIMULATION, 2010, 3 (01) : 1 - 2
  • [48] The relationship between outdoor air quality and respiratory symptoms in young children
    Rodriguez, Clemencia
    Tonkin, Russell
    Heyworth, Jane
    Kusel, Merci
    De Klerk, Nick
    Sly, Peter D.
    Franklin, Peter
    Runnion, Tina
    Blockley, Adrian
    Landau, Louis
    Hinwood, Andrea L.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL HEALTH RESEARCH, 2007, 17 (05) : 351 - 360
  • [49] Child exposure to indoor and outdoor air pollutants in schools in Barcelona, Spain
    Rivas, I.
    Viana, M.
    Moreno, T.
    Pandolfi, M.
    Amato, F.
    Reche, C.
    Bouso, L.
    Alvarez-Pedrerol, M.
    Alastuey, A.
    Sunyer, J.
    Querol, X.
    ENVIRONMENT INTERNATIONAL, 2014, 69 : 200 - 212
  • [50] Developing successful partnerships to improve indoor air quality in schools using the US EPA indoor air quality tools for schools
    Benoit, E
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 3510 - 3513