Relationship between outdoor and indoor air quality in eight French schools

被引:254
|
作者
Blondeau, P [1 ]
Iordache, V [1 ]
Poupard, O [1 ]
Genin, D [1 ]
Allard, F [1 ]
机构
[1] Univ La Rochelle, LEPTAB, F-17042 La Rochelle 1, France
关键词
I/O ratios; ozone; nitrogen oxides; particle size distribution; school; building air-tightness; ventilation;
D O I
10.1111/j.1600-0668.2004.00263.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the frame of the French national research program PRIMEQUAL (inter-ministry program for better air quality in urban environments), measurements of outdoor and indoor pollution have been carried out in eight schools in La Rochelle (France) and its suburbs. The buildings were naturally ventilated by opening the windows, or mechanically ventilated, and showed various air permeabilities. Ozone, nitrogen oxides (NO and NO2), and airborne particle (particle counts within 15 size intervals ranging from 0.3 to 15 mum) concentrations were continuously monitored indoors and outdoors for two 2-week periods. The indoor humidity, temperature, CO2 concentration (an indicator of occupancy), window openings and building permeability were also measured. The temporal profiles of indoor and outdoor concentrations show ozone and nitrogen oxides behave differently: NO and NO2 indoor/outdoor concentration ratios (I/O) were found to vary in a range from 0.5 to 1, and from 0.88 to 1, respectively, but no correlation with building permeability was observed. On the contrary, I/O ratios of ozone vary in a range from 0 to 0.45 and seem to be strongly influenced by the building air-tightness: the more airtight the building envelope, the lower the ratio. Occupancy, through re-suspension of previously deposited particles and possible particle generation, strongly influences the indoor concentration level of airborne particles. However, this influence decreases with particle size, reflecting the way deposition velocities vary as a function of size. The influence of particle size on deposition and penetration across the building envelope is also discussed by analyzing the I/O ratios measured when the buildings were unoccupied, by comparing the indoor concentrations measured when the buildings were occupied and when they were not (O/U ratios), and by referring to previously published studies focussing on this topic. Except one case, I/O were found to vary in the range from 0.03 to 1.79. All O/U are greater than one and increase up to 100 with particle size.
引用
收藏
页码:2 / 12
页数:11
相关论文
共 50 条
  • [11] Indoor air quality in schools
    Gianluigi de Gennaro
    Paolo Rosario Dambruoso
    Annamaria Demarinis Loiotile
    Alessia Di Gilio
    Pasquale Giungato
    Maria Tutino
    Annalisa Marzocca
    Antonio Mazzone
    Jolanda Palmisani
    Francesca Porcelli
    Environmental Chemistry Letters, 2014, 12 : 467 - 482
  • [12] Indoor air quality in schools
    de Gennaro, Gianluigi
    Dambruoso, Paolo Rosario
    Loiotile, Annamaria Demarinis
    Di Gilio, Alessia
    Giungato, Pasquale
    Tutino, Maria
    Marzocca, Annalisa
    Mazzone, Antonio
    Palmisani, Jolanda
    Porcelli, Francesca
    ENVIRONMENTAL CHEMISTRY LETTERS, 2014, 12 (04) : 467 - 482
  • [13] Indoor air quality in schools
    Cartieaux, E.
    Rzepka, M. -A.
    Cuny, D.
    ARCHIVES DE PEDIATRIE, 2011, 18 (07): : 789 - 796
  • [14] INDOOR/OUTDOOR AIR QUALITY RELATIONSHIPS
    YOCOM, JE
    CLINK, WL
    COTE, WA
    JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1971, 21 (05): : 251 - &
  • [15] COMPARATIVE INDOOR AND OUTDOOR AIR QUALITY
    YOCOM, JE
    ASHRAE JOURNAL, 1970, 12 (01): : 53 - &
  • [16] Correlation between indoor and outdoor air
    Radaideh, J. A.
    Shatnawi, Z.
    AIR POLLUTION XXIII, 2015, 198 : 357 - 367
  • [17] Perceived indoor air quality and its relationship to air pollutants in French dwellings
    Langer, S.
    Ramalho, O.
    Le Ponner, E.
    Derbez, M.
    Kirchner, S.
    Mandin, C.
    INDOOR AIR, 2017, 27 (06) : 1168 - 1176
  • [18] Indoor air quality in primary schools
    Canha, Nuno
    Martinho, Maria
    Almeida-Silva, Marina
    Freitas, Maria do Carmo
    Almeida, Susana Marta
    Pegas, Priscilla
    Alves, Celia
    Pio, Casimiro
    Trancoso, Maria Ascensao
    Sousa, Rita
    Mouro, Filomena
    Contreiras, Teresa
    INTERNATIONAL JOURNAL OF ENVIRONMENT AND POLLUTION, 2012, 50 (1-4) : 396 - 410
  • [19] Indoor air quality and health in schools
    da Conceicao Ferreira, Ana Maria
    Cardoso, Massano
    JORNAL BRASILEIRO DE PNEUMOLOGIA, 2014, 40 (03) : 259 - 268
  • [20] Indoor air quality in Michigan schools
    Godwin, C.
    Batterman, S.
    INDOOR AIR, 2007, 17 (02) : 109 - 121