Relationship between outdoor and indoor air quality in eight French schools

被引:254
|
作者
Blondeau, P [1 ]
Iordache, V [1 ]
Poupard, O [1 ]
Genin, D [1 ]
Allard, F [1 ]
机构
[1] Univ La Rochelle, LEPTAB, F-17042 La Rochelle 1, France
关键词
I/O ratios; ozone; nitrogen oxides; particle size distribution; school; building air-tightness; ventilation;
D O I
10.1111/j.1600-0668.2004.00263.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the frame of the French national research program PRIMEQUAL (inter-ministry program for better air quality in urban environments), measurements of outdoor and indoor pollution have been carried out in eight schools in La Rochelle (France) and its suburbs. The buildings were naturally ventilated by opening the windows, or mechanically ventilated, and showed various air permeabilities. Ozone, nitrogen oxides (NO and NO2), and airborne particle (particle counts within 15 size intervals ranging from 0.3 to 15 mum) concentrations were continuously monitored indoors and outdoors for two 2-week periods. The indoor humidity, temperature, CO2 concentration (an indicator of occupancy), window openings and building permeability were also measured. The temporal profiles of indoor and outdoor concentrations show ozone and nitrogen oxides behave differently: NO and NO2 indoor/outdoor concentration ratios (I/O) were found to vary in a range from 0.5 to 1, and from 0.88 to 1, respectively, but no correlation with building permeability was observed. On the contrary, I/O ratios of ozone vary in a range from 0 to 0.45 and seem to be strongly influenced by the building air-tightness: the more airtight the building envelope, the lower the ratio. Occupancy, through re-suspension of previously deposited particles and possible particle generation, strongly influences the indoor concentration level of airborne particles. However, this influence decreases with particle size, reflecting the way deposition velocities vary as a function of size. The influence of particle size on deposition and penetration across the building envelope is also discussed by analyzing the I/O ratios measured when the buildings were unoccupied, by comparing the indoor concentrations measured when the buildings were occupied and when they were not (O/U ratios), and by referring to previously published studies focussing on this topic. Except one case, I/O were found to vary in the range from 0.03 to 1.79. All O/U are greater than one and increase up to 100 with particle size.
引用
收藏
页码:2 / 12
页数:11
相关论文
共 50 条
  • [21] COMPARISON OF INDOOR AND OUTDOOR AIR QUALITY.
    Moschandreas, D.J.
    Zabransky, J.
    Pelton, D.J.
    Electric Power Research Institute (Report) EPRI EA, 1981,
  • [22] Monitoring indoor air quality in French schools and day-care centers
    Michelot, Nicolas
    Marchand, Caroline
    Ramalho, Olivier
    Delmas, Veronique
    Carrega, Marie
    HVAC&R RESEARCH, 2013, 19 (08): : 1083 - 1089
  • [23] Investigation of indoor air quality and indoor/outdoor relationship in three different microenvironments of central part of India
    Lawrence, AJ
    Taneja, A
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 797 - 801
  • [24] Indoor air quality in schools and its relationship with children's respiratory symptoms
    Madureira, Joana
    Paciencia, Ines
    Rufo, Joao
    Ramos, Elisabete
    Barros, Henrique
    Teixeira, Joao Paulo
    Fernandes, Eduardo de Oliveira
    ATMOSPHERIC ENVIRONMENT, 2015, 118 : 145 - 156
  • [25] Relationships between indoor and outdoor air quality during the summer seasons in Korea
    Lee, HS
    Kang, BW
    Cheong, JP
    Lee, SK
    ATMOSPHERIC ENVIRONMENT, 1997, 31 (11) : 1689 - 1693
  • [26] A review on interactions between energy performance of the buildings, outdoor air pollution and the indoor air quality
    Spiru, Paraschiv
    Simona, Paraschiv Lizica
    INTERNATIONAL SCIENTIFIC CONFERENCE - ENVIRONMENTAL AND CLIMATE TECHNOLOGIES (CONECT 2017), 2017, 128 : 179 - 186
  • [27] Relationship between buildability, indoor air quality and visual performance
    Pheng, Low Sui
    Ying, Liu Jun
    Lock, Wong Heng
    Structural Survey, 2008, 26 (01) : 38 - 54
  • [28] Associated relationship between ventilation rates and indoor air quality
    Cao, Shi-Jie
    Zhu, Dong-Hao
    Yang, Yin-Bao
    RSC ADVANCES, 2016, 6 (112): : 111427 - 111435
  • [29] Investigation of the Relationship Between Indoor Air Quality and Physical Activity
    Lawson, Christopher
    McCullagh, Paul
    Cruciani, Federico
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON UBIQUITOUS COMPUTING & AMBIENT INTELLIGENCE (UCAMI 2022), 2023, 594 : 547 - 558
  • [30] Characterization of indoor air quality using an indoor/outdoor microenvironmental model
    Glytsos, T.
    Smolvk, J.
    Lazaridis, M.
    RECENT PROGRESS IN COMPUTATIONAL SCIENCES AND ENGINEERING, VOLS 7A AND 7B, 2006, 7A-B : 678 - +