Relationship between outdoor and indoor air quality in eight French schools

被引:254
|
作者
Blondeau, P [1 ]
Iordache, V [1 ]
Poupard, O [1 ]
Genin, D [1 ]
Allard, F [1 ]
机构
[1] Univ La Rochelle, LEPTAB, F-17042 La Rochelle 1, France
关键词
I/O ratios; ozone; nitrogen oxides; particle size distribution; school; building air-tightness; ventilation;
D O I
10.1111/j.1600-0668.2004.00263.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the frame of the French national research program PRIMEQUAL (inter-ministry program for better air quality in urban environments), measurements of outdoor and indoor pollution have been carried out in eight schools in La Rochelle (France) and its suburbs. The buildings were naturally ventilated by opening the windows, or mechanically ventilated, and showed various air permeabilities. Ozone, nitrogen oxides (NO and NO2), and airborne particle (particle counts within 15 size intervals ranging from 0.3 to 15 mum) concentrations were continuously monitored indoors and outdoors for two 2-week periods. The indoor humidity, temperature, CO2 concentration (an indicator of occupancy), window openings and building permeability were also measured. The temporal profiles of indoor and outdoor concentrations show ozone and nitrogen oxides behave differently: NO and NO2 indoor/outdoor concentration ratios (I/O) were found to vary in a range from 0.5 to 1, and from 0.88 to 1, respectively, but no correlation with building permeability was observed. On the contrary, I/O ratios of ozone vary in a range from 0 to 0.45 and seem to be strongly influenced by the building air-tightness: the more airtight the building envelope, the lower the ratio. Occupancy, through re-suspension of previously deposited particles and possible particle generation, strongly influences the indoor concentration level of airborne particles. However, this influence decreases with particle size, reflecting the way deposition velocities vary as a function of size. The influence of particle size on deposition and penetration across the building envelope is also discussed by analyzing the I/O ratios measured when the buildings were unoccupied, by comparing the indoor concentrations measured when the buildings were occupied and when they were not (O/U ratios), and by referring to previously published studies focussing on this topic. Except one case, I/O were found to vary in the range from 0.03 to 1.79. All O/U are greater than one and increase up to 100 with particle size.
引用
收藏
页码:2 / 12
页数:11
相关论文
共 50 条
  • [31] A PRELIMINARY-STUDY ON THE RELATIONSHIP BETWEEN OUTDOOR AND INDOOR AIR-POLLUTION LEVELS
    DRAKOU, G
    ZEREFOS, C
    ZIOMAS, I
    FRESENIUS ENVIRONMENTAL BULLETIN, 1995, 4 (11): : 689 - 694
  • [32] INDOOR AIR QUALITY IN THE SCHOOLS AND STUDENTS PERFORMANCE
    Senitkova, Ingrid
    Bednarova, Petra
    NANO, BIO AND GREEN - TECHNOLOGIES FOR A SUSTAINABLE FUTURE, VOL II (SGEM 2015), 2015, : 445 - 454
  • [33] Indoor air quality in French housing
    Kirchner, Severine
    Arenes, Jean-Francois
    Cochet, Christian
    Derbez, Mickael
    Duboudin, Cedric
    Elias, Patrick
    Gregoire, Anthony
    Jedor, Beatrice
    Lucas, Jean-Paul
    Pasquier, Nathalie
    Pigneret, Michele
    Ramalho, Olivier
    ENVIRONNEMENT RISQUES & SANTE, 2007, 6 (04): : 259 - 269
  • [34] Schools Flunk the Test on Indoor Air Quality
    Potera, Carol
    AMERICAN JOURNAL OF NURSING, 2011, 111 (08) : 19 - 20
  • [35] STUDY ON INDOOR AIR QUALITY IN TUSCAN SCHOOLS
    Benvenuti, A.
    Miligi, L.
    Balocchini, E.
    Aprea, C.
    Bianchimani, V
    Cercena, P.
    Barghini, F.
    Bertuzzi, L.
    Calafiore, V
    Cassinelli, C.
    Cenni, I
    Corsi, F.
    De Lucis, C.
    La Vecchia, R.
    Maurello, M. T.
    Pinto, I
    Sciarra, G.
    Vicentini, M.
    EPIDEMIOLOGIA & PREVENZIONE, 2010, 34 (5-6): : 135 - 135
  • [36] Schools and Indoor Air Quality: seasonal variation
    Badyda, A.
    Muszynski, A.
    Affek, K.
    Doskocz, N.
    Kepa, P.
    Mucha, D.
    Piorkowska, A.
    Rogulski, M.
    Zaleska-Radziwill, M.
    EUROPEAN JOURNAL OF PUBLIC HEALTH, 2024, 34
  • [37] The Effects of Ventilation on Indoor Air Quality in Schools
    Zhong, Lexuan
    2018 ASHRAE ANNUAL CONFERENCE, 2018,
  • [38] Management of indoor air quality in Canadian schools
    Rollins, K
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 3875 - 3878
  • [39] Microbiological Indoor Air Quality in Polish Schools
    Dumala, Slawomira M.
    Dudzinska, Marzenna R.
    ROCZNIK OCHRONA SRODOWISKA, 2013, 15 : 231 - 244
  • [40] Indoor air quality in old and new schools
    Rumchev, K.
    Ourangui, R.
    Bertolatti, D.
    Spickett, J.
    ENVIRONMENTAL HEALTH RISK IV, 2007, 11 : 25 - +