Relationship between outdoor and indoor air quality in eight French schools

被引:254
|
作者
Blondeau, P [1 ]
Iordache, V [1 ]
Poupard, O [1 ]
Genin, D [1 ]
Allard, F [1 ]
机构
[1] Univ La Rochelle, LEPTAB, F-17042 La Rochelle 1, France
关键词
I/O ratios; ozone; nitrogen oxides; particle size distribution; school; building air-tightness; ventilation;
D O I
10.1111/j.1600-0668.2004.00263.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In the frame of the French national research program PRIMEQUAL (inter-ministry program for better air quality in urban environments), measurements of outdoor and indoor pollution have been carried out in eight schools in La Rochelle (France) and its suburbs. The buildings were naturally ventilated by opening the windows, or mechanically ventilated, and showed various air permeabilities. Ozone, nitrogen oxides (NO and NO2), and airborne particle (particle counts within 15 size intervals ranging from 0.3 to 15 mum) concentrations were continuously monitored indoors and outdoors for two 2-week periods. The indoor humidity, temperature, CO2 concentration (an indicator of occupancy), window openings and building permeability were also measured. The temporal profiles of indoor and outdoor concentrations show ozone and nitrogen oxides behave differently: NO and NO2 indoor/outdoor concentration ratios (I/O) were found to vary in a range from 0.5 to 1, and from 0.88 to 1, respectively, but no correlation with building permeability was observed. On the contrary, I/O ratios of ozone vary in a range from 0 to 0.45 and seem to be strongly influenced by the building air-tightness: the more airtight the building envelope, the lower the ratio. Occupancy, through re-suspension of previously deposited particles and possible particle generation, strongly influences the indoor concentration level of airborne particles. However, this influence decreases with particle size, reflecting the way deposition velocities vary as a function of size. The influence of particle size on deposition and penetration across the building envelope is also discussed by analyzing the I/O ratios measured when the buildings were unoccupied, by comparing the indoor concentrations measured when the buildings were occupied and when they were not (O/U ratios), and by referring to previously published studies focussing on this topic. Except one case, I/O were found to vary in the range from 0.03 to 1.79. All O/U are greater than one and increase up to 100 with particle size.
引用
收藏
页码:2 / 12
页数:11
相关论文
共 50 条
  • [1] Statistical analysis of parameters influencing the relationship between outdoor and indoor air quality in schools
    Poupard, O
    Blondeau, P
    Iordache, V
    Allard, F
    ATMOSPHERIC ENVIRONMENT, 2005, 39 (11) : 2071 - 2080
  • [2] Interventions for improving indoor and outdoor air quality in and around schools
    Rawat, Nidhi
    Kumar, Prashant
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 858
  • [3] Indoor and outdoor air quality investigation at schools in Hong Kong
    Lee, SC
    Chang, M
    CHEMOSPHERE, 2000, 41 (1-2) : 109 - 113
  • [4] Indoor and outdoor air contaminants coupling relationship and measures of improving indoor air quality
    Geng, Shibin
    Xiao, Mingxing
    SUSTAINABLE ENVIRONMENT AND TRANSPORTATION, PTS 1-4, 2012, 178-181 : 711 - 717
  • [5] Particulate Air Pollution at Schools: Indoor-Outdoor Relationship and Determinants of Indoor Concentrations
    Mohammadyan, Mahmoud
    Alizadeh-Larimi, Ahmad
    Etemadinejad, Siavash
    Latif, Mohd Talib
    Heibati, Behzad
    Yetilmezsoy, Kaan
    Abdul-Wahab, Sabah Ahmed
    Dadvand, Payam
    AEROSOL AND AIR QUALITY RESEARCH, 2017, 17 (03) : 857 - 864
  • [6] OUTDOOR/INDOOR AIR QUALITY IN PRIMARY SCHOOLS IN LISBON: A PRELIMINARY STUDY
    Pegas, Priscilla Nascimento
    Evtyugina, Margarita G.
    Alves, Celia A.
    Nunes, Teresa
    Cerqueira, Mario
    Franchi, Mariana
    Pio, Casimiro
    Almeida, Susana Marta
    Freitas, Maria do Carmo
    QUIMICA NOVA, 2010, 33 (05): : 1145 - 1149
  • [7] Seasonal evaluation of outdoor/indoor air quality in primary schools in Lisbon
    Pegas, P. N.
    Alves, C. A.
    Evtyugina, M. G.
    Nunes, T.
    Cerqueira, M.
    Franchi, M.
    Pio, C. A.
    Almeida, S. M.
    Cabo Verde, S.
    Freitas, M. C.
    JOURNAL OF ENVIRONMENTAL MONITORING, 2011, 13 (03): : 657 - 667
  • [8] Modeling relationships between indoor and outdoor air quality
    Freijer, JI
    Bloemen, HJT
    JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2000, 50 (02) : 292 - 300
  • [9] Relationships between indoor and outdoor air quality in Delhi
    Srivastava, A
    Jain, VK
    INDOOR AND BUILT ENVIRONMENT, 2003, 12 (03) : 159 - 165
  • [10] Indoor air quality in schools
    Gianluigi de Gennaro
    Paolo Rosario Dambruoso
    Annamaria Demarinis Loiotile
    Alessia Di Gilio
    Pasquale Giungato
    Maria Tutino
    Annalisa Marzocca
    Antonio Mazzone
    Jolanda Palmisani
    Francesca Porcelli
    Environmental Chemistry Letters, 2014, 12 : 467 - 482