Dynamic Quantitative Iodine Myocardial Perfusion Imaging with Dual-Layer CT using a Porcine Model

被引:6
|
作者
Scherer, Kai [1 ,2 ,3 ,4 ]
Hammel, Johannes [1 ,2 ,3 ,4 ]
Sellerer, Thorsten [3 ,4 ]
Mechlem, Korbinian [3 ,4 ]
Renger, Bernhard [1 ,2 ]
Baehr, Andrea [5 ,6 ]
Kupatt, Christian [5 ,6 ]
Hinkel, Rabea [5 ,6 ,7 ]
Herzen, Julia [3 ,4 ]
Pfeiffer, Franz [1 ,2 ,3 ,4 ,8 ]
Rummeny, Ernst [1 ,2 ]
Pfeiffer, Daniela [1 ,2 ]
机构
[1] Tech Univ Munich, Sch Med, Dept Diagnost & Intervent Radiol, D-81675 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, D-81675 Munich, Germany
[3] Tech Univ Munich, Dept Phys, Chair Biomed Phys, D-85748 Garching, Germany
[4] Tech Univ Munich, Munich Sch BioEngn, D-85748 Garching, Germany
[5] Tech Univ Munich, Klinikum Rechts Isar, Klin & Poliklin Innere Med 1, D-81675 Munich, Germany
[6] DZHK German Ctr Cardiovasc Res, Partner Site Munich Heart Alliance, D-80802 Munich, Germany
[7] Deutsch Primatenzentrum GmbH, Leibniz Inst Primatenforsch, Dept Lab Anim Sci, D-37077 Gottingen, Germany
[8] Tech Univ Munich, Inst Adv Study, D-85748 Garching, Germany
关键词
CORONARY-ARTERY-DISEASE; ENERGY CT; COMPUTED-TOMOGRAPHY; ANGIOGRAPHY; ISCHEMIA;
D O I
10.1038/s41598-019-52458-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Ischemic heart disease is the globally leading cause of death. When using coronary CT angiography, the functional hemodynamics within the myocardium remain uncertain. In this study myocardial CT perfusion imaging using iodine contrast agent demonstrated to strongly improve the assessment of myocardial disorders. However, a retrieval of such dynamics using Hounsfield units from conventional CT poses concerns with respect to beam-hardening effects and low contrast-to-noise ratio (CNR). Dual-energy CT offers novel approaches to overcome aforementioned limitations. Quantitative peak enhancement, perfusion, time to peak and iodine volume measurements inside the myocardium were determined resulting in 0.92 mg/ml, 0.085 mg/ml/s 17.12 s and 29.89 mg/ml*s, respectively. We report on the first extensive quantitative and iodine-based analysis of myocardial dynamics in a healthy porcine model using a dual-layer spectral CT. We further elucidate on the potential of reducing the radiation dose from 135 to 18 mGy and the contrast agent volume from 60 to 30 mL by presenting a two-shot acquisition approach and measuring iodine concentrations in the myocardium in-vivo down to 1 mg/ml, respectively. We believe that dynamic quantitative iodine perfusion imaging may be a highly sensitive tool for the precise functional assessment and monitoring of early myocardial ischemia.
引用
收藏
页数:9
相关论文
共 50 条
  • [11] A Novel Porcine Model of Acute Myocardial Ischemia Guided by FFR for Accuracy of Dynamic CT Myocardial Perfusion Imaging Study
    Zhou, Xiaorong
    Rosenthal, Noah
    Parikh, Sahil A.
    Okere, Isidore
    Rajiah, Prabhakar
    Wilson, David
    Bezerra, Hiram G.
    CIRCULATION, 2013, 128 (22)
  • [12] Myocardial perfusion imaging with dual energy CT
    Jin, Kwang Nam
    De Cecco, Carlo N.
    Caruso, Damiano
    Tesche, Christian
    Spandorfer, Adam
    Varga-Szemes, Akos
    Schoepf, U. Joseph
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (10) : 1914 - 1921
  • [13] Effect of CT Acquisition Parameters on Iodine Density Measurement at Dual-Layer Spectral CT
    Kim, Hyungjin
    Park, Chang Min
    Kang, Chang Kyung
    Yoon, Jinyeong
    Chae, Kum Ju
    Goo, Jin Mo
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (04) : 748 - 754
  • [14] Quantitative analysis of late iodine enhancement using dual-layer spectral detector computed tomography: comparison with magnetic resonance imaging
    Liu, Peijun
    Lin, Lu
    Xu, Cheng
    Han, Yechen
    Lin, Xue
    Hou, Yang
    Lu, Xiaomei
    Vembar, Mani
    Jin, Zhengyu
    Wang, Yining
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (01) : 310 - 320
  • [15] Principles and Applications of Dual-Layer Spectral CT in Gastrointestinal Imaging
    Franco, Paolo Niccolo
    Spasiano, Chiara Maria
    Maino, Cesare
    De Ponti, Elena
    Ragusi, Maria
    Giandola, Teresa
    Terrani, Simone
    Peroni, Marta
    Corso, Rocco
    Ippolito, Davide
    DIAGNOSTICS, 2023, 13 (10)
  • [16] Quantitative Assessment of Radiologically Indeterminate Local Colonic Wall Thickening on Iodine Density Images Using Dual-Layer Spectral Detector CT
    Wang, Guorong
    Fang, Yue
    Wang, Zhiwei
    Jin, Zhengyu
    ACADEMIC RADIOLOGY, 2021, 28 (10) : 1368 - 1374
  • [17] Quantitative myocardial perfusion imaging using rapid kVp switch dual-energy CT: Preliminary experience
    So, Aaron
    Lee, Ting-Yim
    Imai, Yasuhiro
    Narayanan, Suresh
    Hsieh, Jiang
    Kramer, John
    Procknow, Karen
    Leipsic, Jonathon
    LaBounty, Troy
    Min, James
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (06) : 430 - 442
  • [18] Feasibility of Adenosine Stress Dynamic CT for the Assessment of Myocardial Perfusion in a Porcine Animal Model
    Schwarz, Florian
    Bamberg, Fabian
    Sandner, Torleif
    Baloch, Elisabeth
    Hinkel, Rabea
    Wintersperger, Bernd
    Reiser, Maximilian
    Nikolaou, Konstantin
    CIRCULATION, 2010, 122 (21)
  • [19] l Dose Reduction Assessment in Dynamic CT Myocardial Perfusion Imaging in a Porcine Balloon-Induced-Ischemia Model
    Fahmi, Rachid
    Eck, Brendan L.
    Vembar, Mani
    Bezerra, Hiram G.
    Wilson, David L.
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [20] Dynamic Myocardial Perfusion in a Porcine Balloon-induced Ischemia Model using a Prototype Spectral Detector CT
    Fahmi, Rachid
    Eck, Brendan L.
    Fares, Anas
    Levi, Jacob
    Wu, Hao
    Vembar, Mani
    Dhanantwari, Amar
    Bezerra, Hiram G.
    Wilson, David L.
    MEDICAL IMAGING 2015: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2015, 9417