Dynamic Quantitative Iodine Myocardial Perfusion Imaging with Dual-Layer CT using a Porcine Model

被引:6
|
作者
Scherer, Kai [1 ,2 ,3 ,4 ]
Hammel, Johannes [1 ,2 ,3 ,4 ]
Sellerer, Thorsten [3 ,4 ]
Mechlem, Korbinian [3 ,4 ]
Renger, Bernhard [1 ,2 ]
Baehr, Andrea [5 ,6 ]
Kupatt, Christian [5 ,6 ]
Hinkel, Rabea [5 ,6 ,7 ]
Herzen, Julia [3 ,4 ]
Pfeiffer, Franz [1 ,2 ,3 ,4 ,8 ]
Rummeny, Ernst [1 ,2 ]
Pfeiffer, Daniela [1 ,2 ]
机构
[1] Tech Univ Munich, Sch Med, Dept Diagnost & Intervent Radiol, D-81675 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, D-81675 Munich, Germany
[3] Tech Univ Munich, Dept Phys, Chair Biomed Phys, D-85748 Garching, Germany
[4] Tech Univ Munich, Munich Sch BioEngn, D-85748 Garching, Germany
[5] Tech Univ Munich, Klinikum Rechts Isar, Klin & Poliklin Innere Med 1, D-81675 Munich, Germany
[6] DZHK German Ctr Cardiovasc Res, Partner Site Munich Heart Alliance, D-80802 Munich, Germany
[7] Deutsch Primatenzentrum GmbH, Leibniz Inst Primatenforsch, Dept Lab Anim Sci, D-37077 Gottingen, Germany
[8] Tech Univ Munich, Inst Adv Study, D-85748 Garching, Germany
关键词
CORONARY-ARTERY-DISEASE; ENERGY CT; COMPUTED-TOMOGRAPHY; ANGIOGRAPHY; ISCHEMIA;
D O I
10.1038/s41598-019-52458-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Ischemic heart disease is the globally leading cause of death. When using coronary CT angiography, the functional hemodynamics within the myocardium remain uncertain. In this study myocardial CT perfusion imaging using iodine contrast agent demonstrated to strongly improve the assessment of myocardial disorders. However, a retrieval of such dynamics using Hounsfield units from conventional CT poses concerns with respect to beam-hardening effects and low contrast-to-noise ratio (CNR). Dual-energy CT offers novel approaches to overcome aforementioned limitations. Quantitative peak enhancement, perfusion, time to peak and iodine volume measurements inside the myocardium were determined resulting in 0.92 mg/ml, 0.085 mg/ml/s 17.12 s and 29.89 mg/ml*s, respectively. We report on the first extensive quantitative and iodine-based analysis of myocardial dynamics in a healthy porcine model using a dual-layer spectral CT. We further elucidate on the potential of reducing the radiation dose from 135 to 18 mGy and the contrast agent volume from 60 to 30 mL by presenting a two-shot acquisition approach and measuring iodine concentrations in the myocardium in-vivo down to 1 mg/ml, respectively. We believe that dynamic quantitative iodine perfusion imaging may be a highly sensitive tool for the precise functional assessment and monitoring of early myocardial ischemia.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Myocardial Coverage and Radiation Dose in Dynamic Myocardial Perfusion Imaging Using Third-Generation Dual-Source CT
    Takafuji, Masafumi
    Kitagawa, Kakuya
    Ishida, Masaki
    Goto, Yoshitaka
    Nakamura, Satoshi
    Nagasawa, Naoki
    Sakuma, Hajime
    KOREAN JOURNAL OF RADIOLOGY, 2020, 21 (01) : 58 - 67
  • [22] Alternative technique using dual source CT imaging for assessment of myocardial perfusion
    Abdel-Rahman, Amgad S.
    Aly, Heba I.
    Saleh, Mohamed A.
    Ibrahim, Ahmed S.
    Arafa, Hanan M. H.
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2015, 46 (02): : 339 - 354
  • [23] Dynamic myocardial CT perfusion imaging—state of the art
    Olga Sliwicka
    Ioannis Sechopoulos
    Andrea Baggiano
    Gianluca Pontone
    Robin Nijveldt
    Jesse Habets
    European Radiology, 2023, 33 : 5509 - 5525
  • [24] The Application of Dual-layer Spectral Detector CT in Abdominal Vascular Imaging
    Lai, Lu-Yao
    Jiang, Ying
    Shu, Jian
    CURRENT MEDICAL IMAGING, 2023, 19 (14) : 1609 - 1615
  • [25] Validation of myocardial perfusion quantification by dynamic CT in an ex-vivo porcine heart model
    Gert Jan Pelgrim
    Marco Das
    Sjoerd van Tuijl
    Marly van Assen
    Frits W. Prinzen
    Marco Stijnen
    Matthijs Oudkerk
    Joachim E. Wildberger
    Rozemarijn Vliegenthart
    The International Journal of Cardiovascular Imaging, 2017, 33 : 1821 - 1830
  • [26] Validation of myocardial perfusion quantification by dynamic CT in an ex-vivo porcine heart model
    Pelgrim, Gert Jan
    Das, Marco
    van Tuijl, Sjoerd
    van Assen, Marly
    Prinzen, Frits W.
    Stijnen, Marco
    Oudkerk, Matthijs
    Wildberger, Joachim E.
    Vliegenthart, Rozemarijn
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (11): : 1821 - 1830
  • [27] Separating High-Z Oral Contrast From Intravascular Iodine Contrast in an Animal Model Using Dual-Layer Spectral CT
    Soesbe, Todd C.
    Lewis, Matthew A.
    Nasr, Khaled
    Ananthakrishnan, Lakshmi
    Lenkinski, Robert E.
    ACADEMIC RADIOLOGY, 2019, 26 (09) : 1237 - 1244
  • [28] Myocardial perfusion imaging using PET/CT
    Dunet, V.
    Prior, J. -O.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2011, 35 (05): : 336 - 343
  • [29] Imaging cardiac ischemia with 128-Slice Dual Source CT - comparison of CT myocardial perfusion imaging with nuclear myocardial perfusion imaging
    Ho, K. T.
    Panknin, C.
    Chua, K. C.
    Klotz, E.
    EUROPEAN HEART JOURNAL, 2010, 31 : 580 - 580
  • [30] Quantitative and qualitative assessment of plasma cell dyscrasias in dual-layer spectral CT
    S. C. Brandelik
    S. Skornitzke
    T. Mokry
    S. Sauer
    W. Stiller
    J. Nattenmüller
    H. U. Kauczor
    T. F. Weber
    T. D. Do
    European Radiology, 2021, 31 : 7664 - 7673