Dynamic Quantitative Iodine Myocardial Perfusion Imaging with Dual-Layer CT using a Porcine Model

被引:6
|
作者
Scherer, Kai [1 ,2 ,3 ,4 ]
Hammel, Johannes [1 ,2 ,3 ,4 ]
Sellerer, Thorsten [3 ,4 ]
Mechlem, Korbinian [3 ,4 ]
Renger, Bernhard [1 ,2 ]
Baehr, Andrea [5 ,6 ]
Kupatt, Christian [5 ,6 ]
Hinkel, Rabea [5 ,6 ,7 ]
Herzen, Julia [3 ,4 ]
Pfeiffer, Franz [1 ,2 ,3 ,4 ,8 ]
Rummeny, Ernst [1 ,2 ]
Pfeiffer, Daniela [1 ,2 ]
机构
[1] Tech Univ Munich, Sch Med, Dept Diagnost & Intervent Radiol, D-81675 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, D-81675 Munich, Germany
[3] Tech Univ Munich, Dept Phys, Chair Biomed Phys, D-85748 Garching, Germany
[4] Tech Univ Munich, Munich Sch BioEngn, D-85748 Garching, Germany
[5] Tech Univ Munich, Klinikum Rechts Isar, Klin & Poliklin Innere Med 1, D-81675 Munich, Germany
[6] DZHK German Ctr Cardiovasc Res, Partner Site Munich Heart Alliance, D-80802 Munich, Germany
[7] Deutsch Primatenzentrum GmbH, Leibniz Inst Primatenforsch, Dept Lab Anim Sci, D-37077 Gottingen, Germany
[8] Tech Univ Munich, Inst Adv Study, D-85748 Garching, Germany
关键词
CORONARY-ARTERY-DISEASE; ENERGY CT; COMPUTED-TOMOGRAPHY; ANGIOGRAPHY; ISCHEMIA;
D O I
10.1038/s41598-019-52458-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Ischemic heart disease is the globally leading cause of death. When using coronary CT angiography, the functional hemodynamics within the myocardium remain uncertain. In this study myocardial CT perfusion imaging using iodine contrast agent demonstrated to strongly improve the assessment of myocardial disorders. However, a retrieval of such dynamics using Hounsfield units from conventional CT poses concerns with respect to beam-hardening effects and low contrast-to-noise ratio (CNR). Dual-energy CT offers novel approaches to overcome aforementioned limitations. Quantitative peak enhancement, perfusion, time to peak and iodine volume measurements inside the myocardium were determined resulting in 0.92 mg/ml, 0.085 mg/ml/s 17.12 s and 29.89 mg/ml*s, respectively. We report on the first extensive quantitative and iodine-based analysis of myocardial dynamics in a healthy porcine model using a dual-layer spectral CT. We further elucidate on the potential of reducing the radiation dose from 135 to 18 mGy and the contrast agent volume from 60 to 30 mL by presenting a two-shot acquisition approach and measuring iodine concentrations in the myocardium in-vivo down to 1 mg/ml, respectively. We believe that dynamic quantitative iodine perfusion imaging may be a highly sensitive tool for the precise functional assessment and monitoring of early myocardial ischemia.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Quantitative assessment of myocardial perfusion by magnetic resonance imaging in the isolated porcine heart
    Andreas Schuster
    Amedeo Chiribiri
    Masaki Ishida
    Matthias Paul
    Shazia Hussain
    Niloufar Zarinabad Nooralipour
    Geraint Morton
    Roy Jogiya
    Divaka Perera
    Tobias Schaeffter
    Sven Plein
    Eike Nagel
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)
  • [42] Dual-energy CT and its potential use for quantitative myocardial CT perfusion
    So, Aaron
    Hsieh, Jiang
    Narayanan, Suresh
    Thibault, Jean-Baptiste
    Imai, Yasuhiro
    Dutta, Sandeep
    Leipsic, Jonathon
    Min, James
    LaBounty, Troy
    Lee, Ting-Yim
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (05) : 308 - 317
  • [43] Dynamic myocardial stress perfusion imaging using fast dual-source CT with alternating table positions: initial experience
    Fabian Bamberg
    Ernst Klotz
    Thomas Flohr
    Alexander Becker
    Christoph R. Becker
    Bernhard Schmidt
    Bernd J. Wintersperger
    Maximilian F. Reiser
    Konstantin Nikolaou
    European Radiology, 2010, 20 : 1168 - 1173
  • [44] Dynamic myocardial stress perfusion imaging using fast dual-source CT with alternating table positions: initial experience
    Bamberg, Fabian
    Klotz, Ernst
    Flohr, Thomas
    Becker, Alexander
    Becker, Christoph R.
    Schmidt, Bernhard
    Wintersperger, Bernd J.
    Reiser, Maximilian F.
    Nikolaou, Konstantin
    EUROPEAN RADIOLOGY, 2010, 20 (05) : 1168 - 1173
  • [45] Perfusion-ventilation CT via three-material differentiation in dual-layer CT: a feasibility study
    Sauter, Andreas P.
    Hammel, Johannes
    Ehn, Sebastian
    Achterhold, Klaus
    Kopp, Felix K.
    Kimm, Melanie A.
    Mei, Kai
    Laugerette, Alexis
    Pfeiffer, Franz
    Rummeny, Ernst J.
    Pfeiffer, Daniela
    Noel, Peter B.
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [46] Improvement of Breast Cancer Detection Using Dual-Layer Spectral CT
    Hasse, Felix Christian
    Giannakis, Athanasios
    Wehrse, Eckhard
    Stiller, Wolfram
    Wallwiener, Markus
    Kauczor, Hans-Ulrich
    Weber, Tim F.
    Heil, Jorg
    Mokry, Theresa
    DIAGNOSTICS, 2024, 14 (14)
  • [47] Technical prerequisites and imaging protocols for dynamic and dual energy myocardial perfusion imaging
    Cannao, Paola M.
    Schoepf, U. Joseph
    Muscogiuri, Giuseppe
    Wichmann, Julian L.
    Fuller, Stephen R.
    Secchi, Francesco
    Varga-Szemes, Akos
    De Cecco, Carlo N.
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (12) : 2401 - 2410
  • [48] Perfusion-ventilation CT via three-material differentiation in dual-layer CT: a feasibility study
    Andreas P. Sauter
    Johannes Hammel
    Sebastian Ehn
    Klaus Achterhold
    Felix K. Kopp
    Melanie A. Kimm
    Kai Mei
    Alexis Laugerette
    Franz Pfeiffer
    Ernst J. Rummeny
    Daniela Pfeiffer
    Peter B. Noël
    Scientific Reports, 9
  • [49] Quantitative myocardial perfusion from static cardiac and dynamic arterial CT
    Bindschadler, Michael
    Branch, Kelley R.
    Alessio, Adam M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (10):
  • [50] EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging
    Roberto Sciagrà
    Mark Lubberink
    Fabien Hyafil
    Antti Saraste
    Riemer H. J. A. Slart
    Denis Agostini
    Carmela Nappi
    Panagiotis Georgoulias
    Jan Bucerius
    Christoph Rischpler
    Hein J. Verberne
    European Journal of Nuclear Medicine and Molecular Imaging, 2021, 48 : 1040 - 1069